MIX TURBO – Cooker hood
OPERATION MANUAL
Specifications
Extraction rate
420m
3
/h
Rated voltage
230V-50Hz
Power consumption
160 W
Light bulbs
2x25W (MAX 2x25W)
Air outlet
90mmx90mm
General safety and installation conditions:
When installing the appliance, follow the conditions and guidelines given in this operating manual.
This appliance is intended for domestic use only. In case of commercial use in food business, warranty
conditions change.
Do not remove the plug from the power socket by pulling the cord.
The power cord must not touch any hot surface.
Do not turn the appliance on if the power cord is damaged.
The cooker hood, if used to extract cooking fumes outside, should be connected to an appropriate
ventilation duct (do not connect it to flues, smoke or exhaust ducts which are in use).
The manufacturer assumes no responsibility for any damage caused by the installation not conforming
to the operating manual.
Any changes made in the structure of the hood by unauthorized persons will result in the exclusion
of the liability of the manufacturer.
If the cooker hood is used simultaneously with devices burning gas or other fuels, the room should be
appropriately ventilated (not applicable in the case of closed circulating system).
Do not use naked flame directly under the cooker hood,
If the non-detachable power cord is damaged, it should be replaced with a special cord available
from the manufacturer or a specialized repair shop.
The exhaust air from the hood must not be discharged into a flue used for discharging exhaust fumes
from appliances burning gas or other fuels (not applicable in the case of closed circulation system).
Before connecting the cooker hood to the mains power supply and checking its correct functioning,
always check if the power cord is properly installed and has not been pinched by the hood during
installation.
Before cleaning, unplug the power cord.
Cleaning not carried out in accordance with the manual constitutes a fire hazard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge of the appliance, unless they are given
supervision or instructions according to the operating manual by persons responsible for their safety.
Purpose and operations
The hood is intended for operation in a suction mode, discharging the fumes outside, or for operation
in a filter mode as a closed circulation system.
Installation
The minimum distance between the surface on which dishes are placed on the heating appliance and
1the lowest part of the cooker hood should be no less than 45cm in the case of electric stoves and no
less than 65cm in the case of gas or dual electric/gas stoves. If the manual of the heating appliance
recommends a larger distance for installation of a cooker hood, you must comply with these instructions.
Installation of the hood and the hood’s casing pipe is shown in Figure
S3
. When installing the hood,
you should observe the general regulations on discharging air from the room. You should take into
account the fact that the use of spiral aluminium pipes reduces the efficiency of the hood and increases
the noise level of the flowing air.