Page 3: ...g the Remote Control 9 Remote Control Maintenance 9 Maintenance and care 10 Metal grease filter 10 Open the metal grease filter 11 Charcoal filter 12 Changing the light bulb 13 What to do if 14 Service and spare parts 15 Guarantee Conditions 16 Technical Details 17 Mounting accessories included 17 Electrical connection 17 Safety warnings for the electrician 17 Wall unit mounting 18 ...

Page 4: ...tic circuit breaker It is very important to clean the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up resulting in a fire hazard For the installer When used as an extractor unit the hood must be fitted with a 150mm diameter hose Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof it ...

Page 5: ...rge to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm2 which is to say a larger hole could reduce the performance of the extractor hood If...

Page 6: ...side through a pipe which must be fitted to connection flange D Fig 1 Remove the grease filters and remove the Charcoal Filter K from its housing by unscrewing the two screws that fix it to the hood Refit the grease filters Fig 2 In order to obtain the best performance the hose should have a diameter equal to the outlet hole Should there already be a pipe of diameter 125 mm that ducts to the outsi...

Page 7: ... and returned to the kitchen through the top grill of the outlet pipe You will need an original AEG charcoal filter for the filtering function Fix the deflector E using 2 screws Ø 3 5x6 5 mm Fig 3 Fix the connection flange G using 2 screws Ø 3 5x6 5 mm Fig 3 Fig 3 E G ...

Page 8: ...F 5 Filter reset 6 Light ON OFF F Saturated filter indicator light BUTTON 4 Activates and deactivates the timer Automatically turns the appliance off at the speed in operation LED on timer activated Duration 5 or 15 minutes as set BUTTON 5 Once you have replaced the charcoal filters press this button for at least 3 seconds until the light turns off BUTTON 4 5 Remote control code programming Keep b...

Page 9: ...ergents Follow the instructions below in order to replace the battery for the remote control Raise the cover on the base of the remote control in order to access the battery compartment Remove the old battery and replace it with a new battery type 23A 12V Fit the new battery taking care to check the polarity as indicated on the base of the battery compartment Warning If the remote control doesn t ...

Page 10: ...rille using a damp cloth and delicate detergents It is extremely important to clean the unit and change the filters at the recommended intervals Failure to do so will cause grease deposits to build up that could constitute a fire hazard Metal grease filter The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used either in the external e...

Page 11: ...epeat the process if necessary Refit the grease filters when they are dry Dishwasher Place grease filters in the dishwasher Select most powerful washing programme and highest temperature at least 65 C Repeat the process Refit the grease filters when they are dry When washing the metal grease filter in the dishwasher a slight discolouration of the filter can occur this does not have any impact on i...

Page 12: ...ilters are available from your local Service Force Centre Fitting the charcoal filter Unplug the unit or disconnect it from the power supply Remove the metal grease filter Fig 4 Fit the charcoal filter and fix it to the body of the hood with two supplied screws Fig 5 Refit the metal grease filters To remove proceed in reverse order Always specify the hood model code number and serial number when o...

Page 13: ...motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp cover use a screw driver as a lever Fig 6 Replace the old bulb with a new one of the same type Remount the lamp cover If the light does not come on make sure the bulb has been inserted correctly b...

Page 14: ...check that the ducting and outlets are not blocked The cooker hood has The safety cut out device has been switched off during operation tripped Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists c...

Page 15: ...Please note that proof of purchase is required for in guarantee service calls Help us to help you Please determine your type of enquiry before writing or telephoning When you contact us we need to know Your name Address and post code Telephone number Clear and concise details of the fault Name and model of the appliance E number This information can be found on the rating plate which can be seen w...

Page 16: ...s 5 Repairs carried out under guarantee do not extend the guarantee period for the appliance Parts removed during guarantee repairs become the property of AEG 6 The purchaser s statutory rights are not affected by this guarantee European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications The guar...

Page 17: ...specifications and colours as a result of our policy of continuing technological development Electrical connection Safety warnings for the electrician The electric outlet should be placed on the wall inside the chimney The hood has a power cable 150 cm with earth connection and the rated voltage is 220 240 V Connect the hood to the mains supply via a double pole switch which has 3 mm minimum separ...

Page 18: ...ly with two screws and washers 8 check that all four screws are securely tightened Fit an exhausting pipe 9 to connect the outlet hole D of the hood to the connection flange G of the deflector E Filter version or to the outside Extractor version Make electrical connection 10 but leave the hood disconnected from the mains supply Fix the circuit board and connection block unit on the top side of the...

Page 19: ...19 Fig 7 1 2 3 4 E G 5 6 7 7 8 9 D 10 11 12 13a 13a 13b 14 15 16 17 17 ...

Page 20: ...AEG Hausgeräte GmbH Postfach 1036 D 90327 Nürnberg http www aeg co uk Copyright by AEG LI1ØBA Ed 07 02 TØ8Ø4 ...