background image

I N S T RU C T I O N   B O O K

FOR ELECTROLUX

COOKER HOOD

EFG 525 and EFG 530

cod. 4329075 08 - 010911

UK

Summary of Contents for EFG 525

Page 1: ...INSTRUCTION BOOK FOR ELECTROLUX COOKER HOOD EFG 525 and EFG 530 cod 4329075 08 010911 UK ...

Page 2: ...nt Safety Information Your Appliance Operating Instructions Cooker Hood Controls To Operate Extraction Recirculation Maintenance and Cleaning External Cleaning Charcoal Filters To Remove the Charcoal Filter Synthetic Grease Filter To Replace the Paper Grease Filter Changing the Light Bulb Something Not Working Service and Spare Parts Guarantee Conditions For the Installer Installation Instructions...

Page 3: ... cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or b...

Page 4: ...tes before you start cooking and leave it running for approximately 15 minutes after finishing Cooker Hood Controls The cooker hood functions are controlled by slide switches located centrally in the front edge of the metal grille panel EFG 525 L Light ON OFF control 0 Off 1 On V Fan Speed Control Position 0 Off Position 1 Low Position 2 Normal Position 3 Boost EFG 530 L Light ON OFF control 0 Off...

Page 5: ...e ducting to the atmosphere Recirculation In the recirculation mode contaminated air is passed through the charcoal filters to be purified and recirculated into the kitchen through a recirculation grille Ensure the charcoal filters are in position When the ducting mode is selected the charcoal filters are not required Never do flambé cooking under this cooker hood Never leave frying pans unattende...

Page 6: ... become saturated and gradually less effective The charcoal filters cannot be cleaned we recommend they are replaced every 3 6 months or more often if the hood is used for more than 3 hours per day To Remove Replace the Charcoal Filters 1 Remove the lower grille supporting the grille with one hand and draw down on the two grey handles located on each side of the grille 2 The charcoal filters are l...

Page 7: ...To refit insert the back edge of the cassette into the rear guide and push up the front edge until the spring catch engages This appliance is a possible fire hazard if the grease filters are not cleaned reguarly and the charcoal filters replaced as recommended Changing the Light Bulb If a lamp fails to function at any time first check that it is fully screwed into the holder To tighten the lamps t...

Page 8: ...ntry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Turn off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a...

Page 9: ... Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Electrolux manufacture which are not marked by Electrolux This guarantee is in addition to your statutory and legal rights ELECTROLUX EUROPEAN GUARANTE...

Page 10: ...equirements Any permanent electrical installation must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before connecting t...

Page 11: ...ting must be fire retardant 125mm 5ins in diameter and the length should be no more than 3 metres with one 90 bend 2 metres with two 90 bends Bends of more than 90 will reduce the efficiency of the hood and reduce the airflow Clearance Height The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated providing the maximum output of the appliance beneath does ...

Page 12: ...require the removal of the metal grille panel Positioning the Cooker Hood Measure the underside of the canopy or kitchen cabinet to mark the position for the cut out The cut out measurement should be 497mm 19 5 8 wide 259mm 10 1 4 deep Check the position of the hole is correct with the measurements above before making the cut out The hood is fixed using the holes located in the rim around the base...

Page 13: ...f the canopy or wall cabinet For the best performan ce use the shortest possible duct run and the minimum number of bends Where flexible ducting is fitted it should not be turned through very tight bends as this may impair the performance of the hood It is recommended a maximum length of 3m to be installed to be reduced 1m for each 90 bend installed in the ducting run If the distance is greater th...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...55 77 High Street Slough BERKSHIRE SL1 1DZ Electrolux Household Appliances Limited 2001 ...

Reviews: