EFG50022

Summary of Contents for EFG50021

Page 1: ...USER MANUAL EFG50021 EFG50022 ...

Page 2: ...We were thinking of you when we made this product ...

Page 3: ... will provide you with lots of pleasure in the future The Electrolux ambition is to offer a wide variety of quality products that make your life more comfortable You find some examples on the cover in this manual Please take a few minutes to study this manual so that you can take advantage of the benefits of your new machine We promise that it will provide a superior User Experience delivering Eas...

Page 4: ...self when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other ty...

Page 5: ...ce it is advisable to switch on the hood a few minutes before you start cooking and leave it running for approximately 15 minutes after finishing Cooker Hood Controls The cooker hood functions are controlled by slide switches located centrally in the front edge of the metal grille panel EFG 50021 L Light ON OFF control 0 Off 1 On V Fan Speed Control Position 0 Off Position 1 Low Position 2 Normal ...

Page 6: ...ilter and out through the ducting to the atmosphere Recirculation In the recirculation mode contaminated air is passed through the charcoal filters to be purified and recirculated into the kitchen through a recirculation grille Ensure the charcoal filters are in position When the ducting mode is selected the charcoal filters are not required Never do flambé cooking under this cooker hood Never lea...

Page 7: ...nts of wa ter when cleaning particularly around the control panel Charcoal Filter The charcoal filters absorb the odours from cooking They will slowly become saturated and gradually less effective The charcoal filters cannot be cleaned we recommend they are replaced every 3 6 months or more often if the hood is used for more than 3 hours per day To Remove Replace the Charcoal Filters 1 Remove the ...

Page 8: ... are not replaced as recommended Metal Grease Filters EFG 50022 The metal grease filters can be machine washed in a dishwasher or hand washed in hot water and a mild detergent or liquid soap To Remove Replace the Metal Filters 1 Press against the metal actuator to release the spring catch 2 Drop the front edge of the cassette down as illustrated opposite and lift the back edge out of the rear guid...

Page 9: ...t ensure not to over tighten them and break the lens When changing the lamps an identical replacement must be fitted to ensure the safe working of the cooker hood The replacement lamp is specified 220 240 volt 40 watt clear cylindrical shape lens with a small Edison E14 screw thread Replacement filters and lamps bulbs can be obtained from your local Service Force Centre ...

Page 10: ...ntee service calls Solution Check the hood is connected to the electricity supply Make sure the switch is in the ON posi tion The fan speed is set high enough for the task The grease filter is clean The kitchen is adequately vented to allow the entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlet...

Page 11: ...y light bulbs or removable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacturer that are not marketed by Electrolux Service and Spare Parts In the e...

Page 12: ...ow the appliance guarantee will move with you subject to the following qualifications The appliance guarantee starts from the date you first purchased the appliance which will be evidenced by production of a valid purchase document issued by the seller of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new country of reside...

Page 13: ...va 370 5 2780609 Verkių 29 LT 09108 Vilnius Luxembourg 35 2 42 43 13 01 Rue de Bitbourg 7 L 1273 Hamm Magyarország 36 1 252 1773 H 1142 Budapest XIV Erzsébet királyné útja 87 Nederland 31 17 24 68 300 Vennootsweg 1 2404 CG Alphen aan den Rijn Norge 47 81 5 30 222 Risløkkvn 2 0508 Oslo Österreich 43 18 66 400 Herziggasse 9 1230 Wien Polska 48 22 43 47 300 ul Kolejowa 5 7 Warsaw Portugal 35 12 14 40...

Page 14: ...ng certifies that this appliance complies with the requirements laid down in EEC directive 89 336 Electromagnetic compatibility and subse quent modifications and Low Voltage directive 72 23 E The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electric...

Page 15: ...ng to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply via a double pole switch having 3mm minimum contact gap on each pole A Switched Fuse Connection Unit to BS1363 Part 4 fitted with a 3 Amp fuse is a recommended mains ...

Page 16: ...sing fixings Ducting The ducting must be fire retardant 125mm 5ins in diameter and the length should be no more than 3 metres with one 90 bend 2 metres with two 90 bends Bends of more than 90 will reduce the efficiency of the hood and reduce the airflow Clearance Height The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated providing the maximum output of...

Page 17: ... above a cooking appliance with a high level grill Unpacking The fittings supplied to install this cooker hood can be found with the instruction book inside the packaging 120 125 mm ducting collar Fitting the Cooker Hood into the Housing Canopy The hood is fixed to the housing using the screw holes located around the base of the casing Access to the screw holes will require the removal of the meta...

Page 18: ...sed through your retailer or DIY store and must be ducted to an outside vent of 125mm 5 minimum The ducting used must be manufac tured from fire retardant material When the hood is ducted externally the charcoal filters must be removed Recirculation If you are using the hood for recirculating ensure the charcoal filters are in position following the instructions below Inserting the Charcoal Filter...

Page 19: ... hood It is recommended a maximum length of 3m to be installed to be reduced 1m for each 90 bend installed in the ducting run If the distance is greater than 3m the efficiency of the hood could be impaired A ducting collar of 120 125 mm 5 is supplied for attaching to ducting if you are using the appliance in the extraction mode If the room where the cooker hood is to be used contains a fuel burnin...