background image

Content Page

General system description / Operating description ....................................................... 2
Safety precautions / Care & maintenance / Technical specifications .............................. 3
System components & package contents ........................................................................ 4
Dimensions ...................................................................................................................... 5
Getting started & changing batteries .............................................................................. 6
Emergency power supply ................................................................................................ 7
Installing the labeling clip / Mounting the locking system… ........................................... 8
Structure of the keypad TA03 / Bolt end position scan function ................................... 10
Factory settings / Opening & closing in Free Code mode. ............................................. 11
Switching to Fixed Code mode / Opening and closing in Fixed Code mode .................. 12
User changes the Fixed Code ........................................................................................ 13
Switching to Free Code mode........................................................................................ 14
Changing the master code ............................................................................................. 15
Changing the emergency opening code ........................................................................ 16
Emergency opening / Reset to factory settings ............................................................. 17
Automatic locking in Fixed Code mode… ...................................................................... 18
Automatic opening in Free Code mode ......................................................................... 19
Battery warning / Firmware update / Disposal ............................................................. 20

www.lehmann-locks.com

Operating Instructions

GB

Locker lock M610 with keypad 

(M610 TA03)

BD

A M610 T

A03 / 2019-09 (GB)

Summary of Contents for M610

Page 1: ...n function 10 Factory settings Opening closing in Free Code mode 11 Switching to Fixed Code mode Opening and closing in Fixed Code mode 12 User changes the Fixed Code 13 Switching to Free Code mode 14 Changing the master code 15 Changing the emergency opening code 16 Emergency opening Reset to factory settings 17 Automatic locking in Fixed Code mode 18 Automatic opening in Free Code mode 19 Batter...

Page 2: ...either in whole or in part without written consent from LEHMANN Vertriebsgesellschaft mbH Co KG IMPORTANT Only install the locking system when it is unlocked For the correct mechanical connection of the locking system to your locker please refer to the installation instructions of your locker manufacturer Perform all programming operations and functional checks when the locker door is open In the ...

Page 3: ... not be charged U U Keep the batteries and packaging material out of children s reach U U Any person swallowing batteries must seek immediate medical advice U U Damaged or leaking batteries may cause acid burns and or poisoning CARE AND MAINTENANCE U U Protect all system components from moisture U U Clean the locking system with a clean soft damp cloth only U U Do not use any aggressive detergents...

Page 4: ...Pin SYSTEM COMPONENTS PACKAGE CONTENTS Please note that these operating instructions apply to different product variants The packaging content therefore depends on the respective product variant The product variants and installation recommendations shown here are intended for furniture with a wood thickness of 19 mm For different wood thicknesses and materials the screws for fixing the lock and th...

Page 5: ... 14 4 4 22 14 6 27 39 1 15 5 4 5 44 10 6 8 14 4 4 22 14 6 27 39 1 15 5 4 5 44 10 105 94 4 9 14 9 4 5 25 94 4 9 105 5 0 1 14 5 2 5 7 2 5 4 Keypad TA03 without labeling clip 88 53 12 ø 1 8 8 64 32 ø3 18 8 ø 15 9 Für Stanzbild ø19 x 16 M610 for right hand doors M610 for left hand doors For Ø19 x 16 ...

Page 6: ...ng the pin into the small holes and releasing the cover Lift the cover off at the same time Insert the batteries CR123A in the battery compartment Make sure that the batteries are correctly inserted in the battery compartment Close the cover of the battery compartment Press the cover until is snaps into all four latch positions IMPORTANT Only use two CR123A primary batteries Keypad TA03 with optio...

Page 7: ... guide lugs of the cover into the recesses Press the cover until it clicks into place EMERGENCY POWER SUPPLY The locking system has the option of an emergency power supply in case of empty batteries INSTALLING THE OPTIONAL LABELING CLIP An individual labeling clip can optionally be attached to the keypad unit 1 2 3 Attach the labeling clip from the rear at the desired position Labeling clip can be...

Page 8: ... i n t h e d o o r INSTALLING THE LOCKING SYSTEM Mounting position of lock M610 Mounting position of keypad TA03 Exemplary for a right door All figures in mm Inlay doors Overlay doors X Door thickness Mounting position of striker plate 4516 32 X Door Sidewall 14 36 5 X 36 5 27 5 45 5 Door Sidewall ...

Page 9: ...nly be ensured if the lock and the keypad lie completely on the door surface except Omega profiles The locker lock M610 is available in two versions right or left mounting Please ensure the correct installation position of the lock and the keypad Tighten the screws hand tight Right mounting front view Left mounting front view In order to attach the cover to the already mounted keypad unit TA03 ins...

Page 10: ...mming operation the already made entries will be discarded after 30 seconds The old code remains valid After the third entry of an invalid code the option to enter a code is blocked for 30 seconds The display flashes red nine times When a key is pressed during these 30 seconds the LED display flashes red once Numbers 0 9 Cancel Enter LED display PLAUSIBILITY CHECK OF BOLT END POSITION The locking ...

Page 11: ...y set master code and factory set emergency opening code OPENING CLOSING IN FREE CODE MODE The lock must be in open position To close you can enter any 3 to 10 digit code When entering make sure that each key input is acknowledged by a light signal at the LED display After opening by entering the correct code the previous code will be deleted The lock can now be closed again with any 3 to 10 digit...

Page 12: ...ode length the code 1 2 3 will automatically be valid In this case the LED display flashes red ten times Check that the code has been accepted correctly with an open cabinet door Switching to Fixed Code mode deactivates the function Automatic opening in Free Code mode or Automatic closing in Fixed Code mode which may have been activated before Enter of master code example factory settings OPENING ...

Page 13: ...w enter your new personal fixed code immediately When entering make sure that the LED display acknowledges each key input If the new code is not entered correctly the previous code remains valid In this case the LED display flashes red ten times Check with the open cabinet that the new fixed code has been accepted correctly see page 12 Opening closing in Fixed Code mode Enter of valid fixed code e...

Page 14: ... Code mode you can operate the lock with any random code 3 to 10 digits Please refer to page 11 Opening closing in Free Code mode Switching to Free Code mode deactivates the function Automatic closing in Fixed Code mode or Automatic opening in Free Code mode which may have been activated before Enter of master code example factory settings Keys 9 0 8 0 7 0 5 5 5 5 x Display The lock is in configur...

Page 15: ... sure that the LED display acknowledges each key input If the new master code has been entered correctly twice there is a long green flashing in the LED display The new master code is valid In all other cases the LED display flashes red ten times The new master code was not accepted The previous master code is still valid Perform immediately a functional test with the new master code Enter of mast...

Page 16: ...ED display acknowledges each key input If the new emergency opening code has been entered correctly twice there is a long green flashing in the LED display The new emergency opening code is valid In all other cases the LED display flashes red ten times The new emergency opening code was not accepted The previous emergency opening code is still valid Perform immediately a functional test with the n...

Page 17: ...he LED display flashes red three times Enter emergency opening code example Werkseinstellung RESET TO FACTORY SETTINGS If the reset to factory settings is carried out all stored fixed code master code emergency opening code and settings will be deleted The lock must be in open position There must be no battery warning If necessary perform an emergency opening to open the lock If you have already c...

Page 18: ...urement is not possible When swit ching to the Free Code mode this function is automatically deactivated Enter of master code example factory settings Keys 9 0 8 0 7 0 5 5 5 5 x Display The lock is in configuration mode continuous green light simultaneously Keys 6 Display The lock waits for the selection of the time span continuous red ight Selection of time spans Automatic closing Keys 0 Display ...

Page 19: ...urement is not possible When swit ching to the Fixed Code mode this function is automatically deactivated Enter of master code example factory settings Keys 9 0 8 0 7 0 5 5 5 5 x Display The lock is in configuration mode continuous green light simultaneously Keys 6 Display The lock waits for the selection of the time span continuous red ight Selection of time spans Automatic opening Keys 0 Display...

Page 20: ...ovided only when needed for example technical need To update the firmware you need the software LEHMANN Firmware Updater The software can be found on the website www lehmann locks com under Electronic Locking Systems and there under Software Solutions The individual steps for updating the firmware are described in the software LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden F...

Reviews: