background image

 

 

 

 

ION C2110  

ION Fast Ethernet Media Converter 

100Base-TX to 100Base-FX

 

      

 

Install Guide  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number 33415 

Revision C August 2023 

 

Summary of Contents for ION C2110

Page 1: ...ION C2110 ION Fast Ethernet Media Converter 100Base TX to 100Base FX Install Guide Part Number 33415 Revision C August 2023...

Page 2: ...om about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically...

Page 3: ...3 Pin Jumper J5 9 J6 E H 3 Pin Jumper Do Not Alter 10 Install the C2110 in the ION Chassis 11 Connect the Fiber Cable 11 Connect the Twisted Pair Copper Cable 12 Operation 12 Status LEDs 12 Product F...

Page 4: ...Lantronix C2110 Install Guide 33415 Rev C https www lantronix com Page 4 of 24 Troubleshooting 21 Compliance Information 22 FCC Regulations 22 Canadian Regulations 22 Declaration of Conformity 23...

Page 5: ...39 100BASE TX RJ 45 100 m 328 ft to 100BASE FX 1300nm MM LC 2 km 1 2 mi Link Budget 11 0 dB C2110 1014 100BASE TX RJ 45 100 m 328 ft to 100BASE FX 1300nm SM SC 20 km 12 4 mi Link Budget 16 0 dB C2110...

Page 6: ...328 ft SC 1300nm single mode 20 km 12 4 miles C2110 1019 RJ 45 100 m 328 ft LC 1300nm single mode 20km 12 4 miles C2110 1039 RJ 45 100 m 328 ft LC 1300nm multimode 2km 1 2miles C2110 1040 RJ 45 100 m...

Page 7: ...ic discharge precautions when setting the 4 position DIP switch and the jumpers Failure to observe this caution could result in C2110 failure or damage Configuration DIP Switches and Jumpers PCB 11322...

Page 8: ...C2110 is connected to auto negotiating device s capable of pause control frame Up Enabled Allows negotiation of pause control frame Down Disabled Does not allow negotiation of pause control frame 3 L...

Page 9: ...bled Use a small needle nose pliers to remove and position the jumper The J4 settings are shown and described below E Enable the C2110 connects automatically to either straight through or crossover tw...

Page 10: ...of 24 J6 E H 3 Pin Jumper Do Not Alter The default setting is E Ethernet Do not change this setting E Ethernet Ethernet mode of operation Default Leave as is H HSTR High Speed Token Ring mode Do not...

Page 11: ...ated into the slot 3 Push in and rotate the attached panel Fastener clockwise to secure the C2110 to the ION chassis Connect the Fiber Cable 1 Locate a 100Base FX compliant fiber cable with a male two...

Page 12: ...onnect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation etc Operation Status LEDs The C2110 is designed to operate without user intervention U...

Page 13: ...half duplex network the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal...

Page 14: ...y disable the TX transmit signal 2 thus passing through the link loss 3 The far end device is notified automatically of the link loss 4 which prevents the loss of valuable data transmitted unknowingly...

Page 15: ...hed terminal or at a remote location to monitor the following C2110 activities Media converter power Copper link status and fiber link status Twisted pair cable length Hardware switch settings Fault c...

Page 16: ...eceiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB C2110 1013 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max...

Page 17: ...100 MHz Maximum Cable Distance 100 meters Straight through or crossover twisted pair cable may be used Shielded twisted pair or unshielded twisted pair may be used Pins 1 2 and 3 6 are the two active...

Page 18: ...t to change This product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture CAUTION Visible and invisible laser radiation when open Do...

Page 19: ...Lantronix C2110 Install Guide 33415 Rev C https www lantronix com Page 19 of 24 PCB Revision Examples PCB 11348 Rev 01 PCB 11348 Rev A...

Page 20: ...Lantronix C2110 Install Guide 33415 Rev C https www lantronix com Page 20 of 24 PCB 11322 Rev 02 PCB 11322 Rev A...

Page 21: ...erify that the TX and RX cables on the C2110 are connected to the RX and TX ports respectively on the other device Contact Technical Support YES Proceed to step 4 4 Is the RXC LED on the C2110 flashin...

Page 22: ...egulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A pres...

Page 23: ...9 C2 C2110 1029 D1 C2110 1029 D2 Conforms to the following Product Regulations EMC Directive 2004 I08 EC EN 55022 2006 A1 2007 Class A EN55024 1998 A1 2001 A2 2003 EN61000 3 2 EN61000 3 3 CFR Title 47...

Page 24: ...48 Discovery Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices For a current lis...