Kaba access manager 92 32

Technical Manual

EN

04045524 - 08/2016

Содержание Access manager 92 32

Страница 1: ...Kaba access manager 92 32 Technical Manual EN 04045524 08 2016 ...

Страница 2: ...nd Phone 41 44 931 61 11 www kaba com Kaba GmbH Access Workforce Management Albertistraße 3 78056 Villingen Schwenningen Germany Phone 49 7720 603 0 www kaba com This document must not be reproduced in any way or otherwise further used without the written consent of Kaba AG All product names are trademarks of the respective companies Copyright 2016 Kaba AG All rights reserved 04045524 08 2016 ...

Страница 3: ... 8 2 5 ESD electrostatic discharge protective measures 9 2 6 Environmental protection 9 3 Product Description 10 3 1 Overview 10 3 2 Areas of application 10 3 3 Technical Data 11 3 3 1 System 11 3 3 2 Power supply 11 3 3 3 Output voltages 11 3 3 4 Outputs 12 3 3 5 Inputs 12 3 3 6 Interfaces 12 3 3 7 LEGIC reader 13 3 3 8 Ambient conditions 13 3 3 9 Dimensions Weight 13 3 3 10 Dimensional drawings ...

Страница 4: ...s 27 5 7 Connections 28 5 7 1 Network connection 28 5 7 2 Overview of terminals 29 5 7 3 External 24 V DC power supply 30 5 7 4 Registration units 31 5 7 5 Inputs 32 5 7 6 Outputs 35 5 8 Vandal contact 40 5 9 Fastening the cover 41 6 Commissioning 42 6 1 Start options 42 6 1 1 Reset key and status LED 42 6 2 Performing a cold start 43 6 3 Commissioning procedure 44 6 3 1 Planning the system in par...

Страница 5: ...ance operations described in this document must be carried out only by service persons according to EN 60950 1 Information technology equipment Safety Service persons are persons having adequate technical training and sufficient experi ence to be aware of and to minimize the possible risks for themselves or other per sons which may occur when carrying out these operations The service persons are r...

Страница 6: ...pplementary documentation is available on the Kaba website The technical man uals are located in a secured area of the website Access is only possible after logging in An account will need to be created before logging in for the first time Access and login 1 In the browser access the Kaba page http www kaba com 2 Select the language in the top right 3 Under Products select the Access Management or...

Страница 7: ...otentially hazardous situation that could result in minor physical in juries NOTICE Information on how to handle the product correctly Failure to comply with these warnings may result in malfunctions The product or something in its vicinity could be damaged 1 7 2 Symbols Depending on the source of the hazard symbols are used for the warnings and these have the following meanings General danger Dan...

Страница 8: ...r 1 Target group Mains voltage installations may only be carried out by a certified specialized com pany or authorized electricians Installation may only be carried out in places that fulfill the climatic and technical conditions stated by the manufacturer The manufacturer is not liable for damages resulting from improper handling or in correct installation 2 3 Service and Maintenance Maintenance ...

Страница 9: ...ent This way static charges are discharged from your body securely and ef fectively Touch only the edges of circuit boards Do not touch the circuit board nor the connector Place all dismantled components on an antistatic surface or in an antistatic con tainer Avoid contact between circuit boards and clothing The wristband only protects the printed circuit boards against electrostatic discharge fro...

Страница 10: ...f RFID media in LEGIC technol ogy Communication with the superior Internet platform takes place via an Ethernet inter face 10BASE T 100BASE TX 1000BASE T Power is supplied over PoE Power over Ethernet As an alternative the power supply can also be performed via an external 24 V DC power supply unit For control and sensors of the door management the device has 4 inputs and 3 out puts 3 2 Areas of a...

Страница 11: ... Input voltage 24 V DC 10 Current consumption max 2 5 A Power of the power supply unit 12 60 W For supply of the device a power output of approx 12 W is necessary Depending on the required power for output voltages additionally up to 48 W for external con sumers Use only power supply units that fulfill the requirements of EN UL CSA 60950 1 as LPS Limited Power Source 3 3 3 Output voltages Use Term...

Страница 12: ...ts 4 digital inputs With integrated power supply and common ground to connect potential free contacts Optional line monitoring LED status display Tamper Switching contact for removal of the housing cover Switching contact for removal of the device from the wall bridge using jumper 3 3 6 Interfaces Ethernet interface IEEE802 3 compatible 10BASE T 100BASE TX 1000BASE T Auto sensing Auto MDIX RS 232 ...

Страница 13: ...pported badge media LEGIC advant 3 3 8 Ambient conditions Ingress protection according to IEC 60529 IP40 Relative humidity 5 to 85 non condensing Ambient temperature 0 C 50 C operation 20 C 65 C storage 3 3 9 Dimensions Weight Length 208 mm Width 208 mm Depth 48 mm Weight approx 0 6 kg 3 3 10 Dimensional drawings Dimensions in mm ...

Страница 14: ...with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interferenc...

Страница 15: ...Council of June 8 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment In addition the product also conforms to the following standards UL 60950 1 UL 294 security performance level 1 The original Declaration of Conformity can be downloaded from www kaba com conformity in PDF format 3 5 Labeling The identification plate is located on the rear of ...

Страница 16: ...due to electrostatic discharge Improper handling can damage or destroy electrostatically sensitive components on printed circuit boards PCB General ESD protective measures must be observed and applied Remove the housing cover in the following way 1 Remove two screws M3x8 TORX 8 on the device bottom side 2 Swivel the bottom side of the cover and disengage it at the top ...

Страница 17: ...rior system Communication with the superior system Internet platform takes place via the Eth ernet network The superior system serves for centralized management of authorizations access and room profiles system configuration and alarm management 4 4 Structure of the registration unit The data collection of identification data is performed via external registration units Type and number of registra...

Страница 18: ...If the door frame contact responds without previous activation of the door opener or pressing of the door handle the access manager sends an alarm record to the Internet platform The functions of the door frame contact and door opener key can be optionally con figured in the door templates of the partner application 4 6 Function of the outputs The function of the individual outputs depends on the ...

Страница 19: ...nits is defined via the door templates in the partner application software Parameterizing information For the two registration units it is not possible to determine different configurations The configuration can be established via address A or address B and is valid for both registration units External inputs relays and vandal contact are not available 4 9 Door templates The access manager can be ...

Страница 20: ...ymbols Fig 1 Light emitting diodes Symbol Designation Signal Meaning Ethernet Lit flashing in yellow Data transfer active Device status state see chapter 4 10 1 see chapter 4 10 1 exivo network see chapter 4 10 1 see chapter 4 10 1 Power Lit in green Power good Lit in red Power fail Off Power off Explanation of the power states State Meaning Power good Device power supply is stable Power fail Load...

Страница 21: ...ng in yellow approx xx sec Waits for possible key actuation cold start Red approx xx sec Waits for possible key actuation default IP Green then flashing in green The terminal software is started Status and error states after system start Signal Meaning Green Terminal software was started success fully Red flashing in green 1 click installation active The device is waiting for registration by the I...

Страница 22: ...or of the area to be secured The access manager must be installed exclusively in interiors Electromagnetic fields The device must not be installed in the area of strong electromagnetic fields caused by switching power supply power lines phase controllers etc 5 1 3 Connections The following connectors must have been prepared at the installation site of the ac cess manager Ethernet network connectio...

Страница 23: ... of the housing on the sides and on the top and bottom they can be removed if necessary The lines are routed in a duct in the lower part of the rear side there is the gland to the connections on the front side NOTICE Ensure sufficient line lengths on the installation site When inserting the lines from the rear center of the housing the installation lines and network cable with the plug protrude fr...

Страница 24: ...ager Method for feeding in the power supply via the PSE Power Sourcing Equip ment End span direct supply e g via PoE switch Midspan supply via intermediate sources e g PoE injector 1 Kaba access manager 92 32 2 Registration unit 3 Door opener key 4 Door opener 5 Door frame contact Installation lines A Coaxial cable to the registration unit B Line to the door contact the door opener key and the doo...

Страница 25: ... Line requirements Cable diameters from 0 5 mm to 0 8 mm Recommended cable CAT 5 S UTP 4 x 2 AWG 24 or AWG 22 according to EIA TIA568 or higher 5 3 3 Coaxial cables to registration units Registration units are connected to the access manager via coaxial cables The coaxial cable transfers the HF signals from the RFID antenna keyboard data and trigger data for the optical and acoustic signal generat...

Страница 26: ...tensions in case of slightly uneven surfaces and cover the fastening hole completely once the screw has been tightened The deliv ered washers must also be used if you use other fastening screws depending on the mounting surface In case of soft mounting surfaces make sure that the housing is not pressed into the surface when mounting it The unevenness of the mounting surface may not exceed 0 5 mm T...

Страница 27: ...ce from the rear side to the front side of the device The cable passage and the internal cover have eyelets for fastening of installation lines by means of cable ties not included in the scope of delivery For the network cable there is a routing duct on the inner cover 5 6 Setting the PoE switches Depending on the power supply type the PoE switch must be set as described be low ...

Страница 28: ...pply unit the switch position PoE is required to prevent the access manager from limiting the power for external con sumers 5 7 Connections 5 7 1 Network connection Establishing the network connection Plug in the network cable into the Ethernet receptacle 1 and fasten it in the gland on the cover If the power supply is correct the Power LED 2 lights up in green after a short time Once the network ...

Страница 29: ...Technical Manual Installation 29 04045524 08 2016 Kaba access manager 92 32 5 7 2 Overview of terminals The following terminals are located in the connection area of the device ...

Страница 30: ...ce NOTICE Possible damage in case of simultaneous power supply via PoE and 24 V DC The device can be damaged in case of simultaneous power supply via PoE and exter nal supply Before connecting the external supply make sure that the device is not supplied with power via PoE Use only power supply units that fulfill the requirements of EN UL CSA 60950 1 as limited power source LPS Also see about this...

Страница 31: ...he registration units A B are con nected by means of the coaxial cable to the RFID input terminal Make sure that antenna A Ant A is connected first and antenna B Ant B is con nected after that Example Connection of Kaba registration unit 90 01 Connection designation Assignment Ant A B Central conductor of coaxial cable GND Shield of coaxial cable ...

Страница 32: ...IN1 IN4 are activated by means of a potential free contact switch or re lay contact An open input is recognized as high due to the internal pull up resis tor 5 7 5 1 Line monitoring The inputs can be designed as follows Without line monitoring With line monitoring if supported and activated by the terminal software Line monitoring allows the terminal software to detect the states short circuit and...

Страница 33: ...s not detected 5 7 5 3 Line monitored inputs With line monitoring activated resistors 680 Ω 0 25 W 2 must be connected in series and in parallel to the respective contact The resistors must be attached in a vandal secure manner directly to the external contact Fig 3 Line monitored inputs of access manager AM 9232 Example Connection to door frame contact line monitored Tampering to lines between ac...

Страница 34: ...s display of the inputs Fig 4 Status display Inputs of access manager AM 9232 The current status of the inputs is indicated by a red and green LED respectively as follows Designation Signal Meaning IN1 IN4 Off Input is not active open lit green Input is active closed red and green lit Short circuit red lit Interruption only with active line monitoring ...

Страница 35: ...e as an alternative OUT1 is used as a potential free contact The internal 12 V DC power supply is switched to the output OUT1 A power supply max 24 VAC applied to the VREL terminal is switched to the output OUT1 The external 24 V DC power supply 24 V EXT terminal is switched to the output OUT1 The outputs OUT2 and OUT3 are designed permanently as potential free relay out puts with one switching co...

Страница 36: ...may not be set 5 7 6 2 Switching 12 V DC to OUT1 By setting the jumper with designation 12 V DC the internal 12 V DC power supply is switched to the OUT1 output Consumers for example door openers which are oper ated with 12 V DC can be directly connected to OUT1 in this way This variant can be used both with device power supply via PoE and device power supply via an external 24 V DC power supply u...

Страница 37: ...r VREL may be set All other jumpers may not be set 5 7 6 4 Switching 24 V DC to OUT1 By setting the jumper pair with designation 24 V DC the 24 V DC power supply ter minal 24 V EXT is switched to the OUT1 output Consumers for example door open ers which are operated with 24 V DC can be directly connected to OUT1 in this way This variant can be used only with device power supply via an external 24 ...

Страница 38: ...n and check the po larity of the connected voltage When using an alternating voltage power supply a varistor or a bipolar suppressor diode must be connected in parallel As regards the dimensioning and type observe the specifications of the door opener manufacturer The diode or varistor must be connected directly to the door opener and may not be fitted to the access manager This step is not requir...

Страница 39: ...32 5 7 6 6 Status display Below the terminals for the outputs there are light emitting diodes for status display of the outputs The current status of the outputs is indicated as follows Designation Signal Meaning REL1 3 Off Relay is not pulled in lit green Relay is pulled in ...

Страница 40: ... if the housing cover is removed Another switching contact 3 is opened if the device is removed from the wall Switching contact 3 is deactivated by the jumper with designation TE 2 in the de livery state To activate the switching contact 3 the jumper TE 2 must be re moved Opening of one or both switching contacts leads to the status indication of the inter nal input 5 ...

Страница 41: ...e cover Fasten the housing cover in the following way 1 Hang the mounting lugs of the housing cover at the top of the bottom part of the housing 2 Pivot the housing cover down and close the housing 3 Fasten the housing cover by means of two screws M3x8 TORX 8 on the bottom part of the housing ...

Страница 42: ...ver and thus an access to the Internet via ports 80 and 443 If the device does not obtain access to the Internet or no functioning DHCP server is available the Ethernet interface must be manually configured using Service Tool be fore putting the device into operation 6 1 Start options 6 1 1 Reset key and status LED The device includes a reset key designated FRES and a status LED State The reset ke...

Страница 43: ...changed 1 Turn off the device 2 Turn on the device ð The yellow status LED is lit ð After approx 40 seconds the yellow status LED starts flashing 3 Within 10 seconds press the reset key and keep it depressed ð The status LED flashes faster for 5 seconds ð The status LED lights up in green for 2 seconds ð A cold start was performed 4 Release the reset key again ð The status LED lights up in red for...

Страница 44: ...lanned in the partner application The device is configured by assigning its installa tion site and the additional hardware components in this software For information on the planning of the system see online help of the parter applica tion 6 3 2 Registering the setup medium in partner application After the system has been planned in the partner application a setup medium for this system also in th...

Страница 45: ...and a SSH terminal program for example PuTTY which can be downloaded from the Internet is required Requirements The following work steps must be carried out to meet the requirements for the use of the Service Tool 1 Install a SSH terminal program e g PuTTY on the computer 2 Download FTDI driver can be obtained from Kaba and install on the computer 3 Connect the FTDI debug cable can also be obtaine...

Страница 46: ... FTDI debug cable is correctly connected to the device and the device is switched on To start the Service Tool proceed as follows 1 Click on Open to start the Service Tool 2 A login screen requesting user name and password will appear The user name and password for all access managers are identical User name admin Password 1234 3 After successful login the main menu of the Service Tool opens Vario...

Страница 47: ...y server Displaying the characteristics of the device The following characteristics can be displayed Firmware version OS AML OSGI Bundles Device ID Serial number date of manufacture IP address MAC address Certificate information Routing table ARP table Uptime Load average Network interface statistics Firewall rules Device statistics Statistics of the connected wireless devices Displaying the syste...

Страница 48: ...ting period of approx 4 minutes by means of the setup medium as follows Hold the setup medium at a registration unit For commissioning of the device by means of the setup medium only a reader with out PIN can be used The access manager will produce 2 consecutive acoustic signals This means that it has detected the setup medium and begins now to communicate with the Kaba exivo Internet platform Aft...

Страница 49: ...e film or put in a bag Pad generously around the device e g using foam padding or bubble wrap It must be ensured that the device does not move within the packaging Only use dust free environmentally friendly filling material 7 2 Electronic Assemblies Electronic assemblies sensitive to ESD such as circuit boards readers etc must be stored transported and sent in suitable ESD protective packaging Th...

Страница 50: ...luded with the package The delivery note should include the following information Number of devices or components per package Item numbers serial numbers designations Address of your company contact Reason for the return e g repair exchange Informative description of the fault In the event of returns from outside of the EU a customs invoice with the real cus toms value and customs tariff no will a...

Страница 51: ...fter use Kaba GmbH undertakes to carry out the proper disposal of the supplied goods in line with legal requirements such as the ElektroG law in Germany All costs incurred for the transport of goods to the manufacturer s plant will be borne by the owner of the used electronic equipment Disposal in Switzerland Send the device to an electronic equipment collection facility as per the VREG regula tio...

Страница 52: ...ts 18 Function of the outputs 18 G Grouped safety messages 8 H HF RFID 12 Hole pattern 26 I Identification plate 15 Ingress protection 13 Inputs 12 32 Inputs Function 18 Installation lines 25 Installation scheme 24 Interfaces 12 L Labeling 15 LEDs Inputs 34 LEDs Outputs 39 Light emitting diodes 20 Limited power source 11 Line monitoring 32 N Network cable 25 Network connection 28 O Output voltages...

Страница 53: ...Technical Manual 53 04045524 08 2016 Kaba access manager 92 32 Weight 13 ...

Отзывы: