Series  N

 

 

 

User’s Manual

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for N Series

Page 1: ...Series N User s Manual...

Page 2: ...1 Chapter 2 Interface Settings Connecting the HS 1M with an RS 232 Port 12 RS 232 Default Settings 13 RS 232 Baud Rate 13 RS 232 Word Length 14 Connecting the HS 1M with USB Port 15 USB Interface Opti...

Page 3: ...Good Read 21 No Reads 22 No Read Message 22 Miscellaneous Indicators 23 Beeper Beep on BEL 23 Beeper Power Up Beep 23 Error LED Duration 23 Aimer Mode 24 Aimer Delay 24 Vibration 25 Vibration Modes 2...

Page 4: ...ow Device Serial Number 31 Chapter 5 Data Editing Data Editing Overview 32 Transmit AIM ID Character 32 Prefixes 33 Prefix Block String 33 Prefix Clear 33 Suffixes 34 Suffix Block String 34 Suffix Cle...

Page 5: ...e 11 Defaults 41 Code 11 On Off 41 Code 11 Minimum and Maximum Length 41 Code 11 Check Digit 42 Code 128 43 Code 128 Defaults 43 Code 128 On Off 43 Code 128 Minimum and Maximum Length 43 ISBT 128 On O...

Page 6: ...AN 8 On Off 48 EAN 13 JAN 13 48 EAN 13 JAN 13 Defaults 48 EAN 13 JAN 13 On Off 48 GS1 128 Formerly UCC EAN128 49 GS1 DataBar Formerly RSS 14 50 GS 1 DataBar Defaults 50 GS 1 DataBar On Off 50 GS1 Data...

Page 7: ...Check Digit 53 Matrix 2 of 5 54 Matrix 2 of 5 Defaults 54 Matrix 2 of 5 On Off 54 Matrix 2 of 5 Minimum and Maximum Length 54 MSI 55 MSI Defaults 55 MSI On Off 55 MSI Minimum and Maximum Length 55 MS...

Page 8: ...um and Maximum Length 60 2D Matrix Symbologies 61 Aztec Code 61 Aztec Code Defaults 61 Aztec Code On Off 61 Aztec Code Minimum and Maximum Length 61 Data Matrix 62 Data Matrix Defaults 62 Data Matrix...

Page 9: ...port Obtaining Technical Assistance or Factory Service 69 Limited Warranty 70 Statement of Agency Compliance 71 FCC Class B Compliance Statement 71 flexpoint HS 1 Series N Declaration of Conformity 72...

Page 10: ...ion is also included JADAK s bar code scanners are factory programmed for the most common terminal and communications settings If you need to change these settings programming is accomplished by scann...

Page 11: ...n string is an 11 digit string with the last 5 digits being a factory configuration number Please consult JADAK for configuration information Note Instead of a configuration string this line can also...

Page 12: ...er when it is farther from the code Symbologies with smaller bars or elements lower mil size should be read closer to the unit Symbologies with larger bars or elements higher mil size as well as 1D ba...

Page 13: ...wer supply connector to the serial interface cable Plug in the power supply to the cable s pigtail and a power outlet in the wall Alternatively power can be supplied via one of the pins of the HS 1M s...

Page 14: ...the correct Baud Rate the data from the HS 1M will be sent to the terminal at the specified rate The baud rate for RS 232 interface can be set by sending the serial command 232BAUD x where x is one o...

Page 15: ...cter If an application requires only ASCII Hex characters 0 through 7F decimal i e text digits and punctuation select 7 data bits For applications that need the full ASCII set supported select 8 data...

Page 16: ...er The driver is available from your JADAK technical support contact No driver is required when using the USB HID Keyboard interface 2 Turn off power to the terminal computer 3 Connect the appropriate...

Page 17: ...gram the HS1 M for USB HID Keyboard mode Note The HS 1M must be power cycled after programming this interface USB HID Keyboard USB COM Port Emulation Scan the following code to program the HS1 M to em...

Page 18: ...lation use the following KBD_CTY commands or programming barcodes to set the specific Keyboard layout for your language Default United States Note These commands are not applicable for RS 232 HS 1M s...

Page 19: ...out an actual Carriage Return hex 0D it will send CR as readable ASCII text Default Disabled Note These commands are not applicable for RS 232 HS 1M s Enable Disable Numeric Keypad Mode Use these com...

Page 20: ...unit to its custom default settings Note The HS 1M must be power cycled after programming this command Note To re set custom defaults please contact JADAK Factory Default Settings Scan the following...

Page 21: ...od Read The beeper may be programmed On or Off in response to a good read Turning this option off only turns off the beeper s response to a good read indication All error and menu beeps are still audi...

Page 22: ...one Good Read Scan one of the following codes to set the tone or pitch of the Good Read beep Default Medium Low Medium High Beeper Time Good Read Scan one of the following codes to set the duration of...

Page 23: ...codes to enable or disable the NR message Default Disable No Read Enable No Read Disable No Read No Read Message The Aforementioned No Read signer NR can be changed if you require a custom message By...

Page 24: ...e HS 1M is equipped with a red LED that usually functions as an indication for errors These commands set the Error LED Duration Time in steps of 1 millisecond from 1ms up to 1 second Default 100 milli...

Page 25: ...scanner s illumination won t show until the delay time has passed This command sets the Aimer Delay Time in steps of 1 millisecond from 1ms up to 4000ms 4 seconds Default Off Several commonly used Ai...

Page 26: ...are sleeping Vibration Modes The HS 1M can use its vibration engine to vibrate in different situations Use one of the codes below to set the vibration mode of the HS 1M Default Disabled Don t vibrate...

Page 27: ...u command barcodes are included below Sample settings Vibration time 100ms Vibration time 200ms Vibration time 300ms Vibration time 500ms If a different vibration time other than those provided is nee...

Page 28: ...urns the trigger ON TRGOFF This command turns the trigger OFF Trigger Modes Manual Trigger level You can activate the HS 1M by pressing the trigger or sending the serial trigger command TRGON When in...

Page 29: ...secutively to set a custom Trigger Time Note TRGTIME 0 sets an infinite Trigger Time Out Sample settings Infinite Trigger Time Out Trigger Time Out 1 0 seconds Trigger Time Out 5 0 seconds Trigger Tim...

Page 30: ...ples No Good Read delay Good Read delay 0 2 seconds Good Read delay 0 5 seconds Good Read delay 1 0 seconds Good Read delay 2 0 seconds Good Read delay 5 0 seconds If a different delay time other than...

Page 31: ...time 600 milliseconds Note Re read Delay only works when the HS 1M is in Presentation Mode Setting examples No Re read delay Re read delay 0 1 seconds Re read delay 0 6 seconds Re read delay 1 0 secon...

Page 32: ...the HS 1M hand scanner Report the list of available Programming Commands All of the supported serial commands of the HS 1M along with a short description and the current setting value will be serially...

Page 33: ...age string The selections in this section are used to build the user defined data into the message string The following illustration shows the breakdown of a message string Transmit AIM ID Character U...

Page 34: ...c ASCII character as Prefix or by scanning the barcode below and then set the ASCII character by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is neede...

Page 35: ...hexadecimal digits to define a specific ASCII character or set of characters as Suffix or by scanning the barcode below and then set the ASCII character by scanning the digit codes and the SAVE barco...

Page 36: ...you need to take an image This chapter describes some of the functions that are related to image capturing Illumination Brightness Use the command LEDSPWR to set the Illumination LEDs Power between Of...

Page 37: ...ge to Host Use the command IMGGETX to get or send an image from the device to the host You can add arguments to this command for specific usage xm sets the send protocol to X Modem jpg sends the image...

Page 38: ...ble Decode Windowing Disable Decode Windowing To define the Decode Window one needs to set the boundaries for Top Bottom Left and Right These boundaries are defined by pixel values within the full fra...

Page 39: ...l value by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is needed Default Left boundary WINDECL 338 Default Right boundary WINDECR 506 Decode Window L...

Page 40: ...28 UPC E GS 1 Databar RSS 14 UPC E1 Note Please contact JADAK if you re looking to scan a symbology that s not listed here All Symbologies If you want to decode all the symbologies allowable for your...

Page 41: ...ombination with numerical values to set the minimum and maximum length for allowed Codabar barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbology...

Page 42: ...ation with numerical values to set the minimum and maximum length for allowed Code 11 barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbology can...

Page 43: ...look for a check digit to decide if the code is valid Code 11 usually has 1 check digit and some codes have 2 check digits Either option can be chosen to be just validated or validated and transmitte...

Page 44: ...The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 0 and 55 or by scanning one of the barcodes below...

Page 45: ...maximum length 48 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 0 and 48 or by scanning one of...

Page 46: ...maceutical industry Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 Default Disabled Note In order for this parameter to work Code 39 must be enabled Enable Disa...

Page 47: ...n with numerical values to set the minimum and maximum length for allowed Code 93 barcodes Default minimum length 0 Default maximum length 55 The minimum and maximum length for this symbology can be s...

Page 48: ...Maximum Length Use the following commands in combination with numerical values to set the minimum and maximum length for allowed Composite Code barcodes Default minimum length 1 Default maximum length...

Page 49: ...ith this code EAN 8 JAN 8 On Off Scan one of the codes below to enable or disable EAN 8 Default Enabled Enable Disable EAN 13 JAN 13 EAN 13 JAN 13 Defaults Set the EAN 13 settings to their default con...

Page 50: ...JADAK flexpoint HS 1M User s Manual Page 49 GS1 128 Formerly UCC EAN128 Scan one of the codes below to enable or disable GS1 128 Decoding Default Enabled Enable Disable...

Page 51: ...aBar On Off Scan one of the codes below to enable or disable GS1 DataBar Default Enabled Enable Disable GS1 DataBar Limited Formerly RSS Limited GS 1 DataBar Limited Defaults Set the GS 1 Databar sett...

Page 52: ...se the following commands in combination with numerical values to set the minimum and maximum length for allowed GS 1 Databar Expanded RSS Expanded barcodes Default minimum length 4 Default maximum le...

Page 53: ...ands in combination with numerical values to set the minimum and maximum length for allowed Interleaved 2 of 5 barcodes Default minimum length 6 Default maximum length 30 The minimum and maximum lengt...

Page 54: ...k Digit The scanner may look for a check digit to decide if the code is valid Interleaved 2 of 5 s USS Uniform Symbology Specification Check digit can be validated and if desired transmitted too Defau...

Page 55: ...combination with numerical values to set the minimum and maximum length for allowed Matrix 2 of 5 barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this s...

Page 56: ...th numerical values to set the minimum and maximum length for allowed MSI barcodes Default minimum length 4 Default maximum length 48 The minimum and maximum length for this symbology can be set eithe...

Page 57: ...tional If the MSI codes include two check digits scan the Two MSI Check Digits bar code to enable verification of the second check digit Default Enable One Check Digit but don t transmit Disable MSI C...

Page 58: ...disable UPC A Default Enabled Enable Disable UPC A Check Digit The check digit is the last character and is used to verify data integrity This digit is always checked but it may be chosen whether or n...

Page 59: ...heck Digit The check digit is the last character and is used to verify data integrity This digit is always checked but it may be chosen whether or not to transmit it Default Transmit Check Digit Trans...

Page 60: ...with numerical values to set the minimum and maximum length for allowed PDF417 barcodes Default minimum length 1 Default maximum length 2750 The minimum and maximum length for this symbology can be s...

Page 61: ...n with numerical values to set the minimum and maximum length for allowed MicroPDF417 barcodes Default minimum length 1 Default maximum length 366 The minimum and maximum length for this symbology can...

Page 62: ...bination with numerical values to set the minimum and maximum length for allowed Aztec barcodes Default minimum length 1 Default maximum length 3832 The minimum and maximum length for this symbology c...

Page 63: ...h numerical values to set the minimum and maximum length for allowed Data Matrix barcodes Default minimum length 1 Default maximum length 3116 The minimum and maximum length for this symbology can be...

Page 64: ...numerical values to set the minimum and maximum length for allowed Maxi Code barcodes Default minimum length 1 Default maximum length 150 The minimum and maximum length for this symbology can be set e...

Page 65: ...rical values to set the minimum and maximum length for allowed QR Code barcodes Default minimum length 1 Default maximum length 7089 The minimum and maximum length for this symbology can be set either...

Page 66: ...5 degrees Horizontal Velocity Up to 230 inch 584 cm per second with 100 UPC at 4 inch 10cm distance Scan Contrast 45 minimum for Matrix codes 20 minimum reflectance Voltage Requirements 4 75 5 25VDC a...

Page 67: ...e HS 1M handle 3 Tied to 5 Volt power 4 Supply Ground 5 6 7 5 Volt power connection 8 9 10 Data RS 232 1 Trigger Line 10 Pin Modular Plug 2 Shield GND connects to the HS 1M handle 3 4 Supply Ground 5...

Page 68: ...a detergent solution is used rinse with a clean lens tissue dampened with water only Cleaning the Scanner Housing The HS 1M is IP54 rated when the cable is attached This means that liquids and dusts w...

Page 69: ...power to the host system OFF 2 Disconnect the HS 1M s cable from the terminal or computer 3 Locate the small triangular label that covers a hole on the bottom of the HS 1M near the cable connection p...

Page 70: ...Return Material Authorization number RMA before returning the product If you need assistance installing or troubleshooting your scanner please contact the JADAK office in your area North America JADA...

Page 71: ...arge except for return shipping to JADAK EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL O...

Page 72: ...radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whic...

Page 73: ...of February 26 2014 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits EMC DIRECTIVE 2014 30 EU as amended Council Direc...

Page 74: ...1000 3 2 2006 A1 2009 A2 2009 Harmonics current 16A EN 61000 3 3 2013 Flicker current 16A EN 62311 2008 EMF Safety Operating Characteristics Parameter Range Operating Voltage 4 75Vdc 5 25Vdc Operating...

Page 75: ...s topic CE Mark Indicates compliance with the Council Directive 93 68 EEC for the European Union WEEE Indicates that electrical and electronic equipment should be disposed of properly and separate fro...

Page 76: ...All available commands are listed on the following pages as well as a brief description of what the parameter choices mean Some commands require further elaboration that can be found in the relevant...

Page 77: ...examples a bracketed notation depicts a non displayable response Query Goal What is the range of possible values for the Code 128 Max Length Send 128MAXL CR Response 0 55 CR Query Goal What is the de...

Page 78: ...8 0 0 0 0 1 C39DEFA Default Code 39 Parameters N A N A N A N A C39ASCI Code 39 Full ASCII Mode 0 0 0 0 1 C39CHEC Code 39 Check Digit 0 none 1 req 2 req xmit 0 0 0 0 1 2 C39ENAB Enable Code 39 Decoding...

Page 79: ...L BEEPPWR 0 to 1 0 Enable power up beep BEPGDRD 0 to 1 1 Enable good read beeper BEPLEVL 0 to 3 3 Beeper level 0 Off 1 Low 2 Medium 3 High BEPTIME 0 to 2 1 Beeper duration 0 short 1 medium 2 long BEPT...

Page 80: ...116 1 Min Data Matrix Symbol Length DNLDAPP Download a firmware moc file via XModem E13DEFA Default EAN13 Parameters E13ENAB 0 to 1 1 Enable Decoding EAN13 EA8DEFA Default EAN8 Parameters EA8ENAB 0 to...

Page 81: ...MSICHEC 0 to 4 0 MSI Enable Check Digit MSIENAB 0 to 1 0 Enable Decoding MSI MSIMAXL 4 to 48 48 Max MSI Symbol Length MSIMINL 4 to 48 4 Min MSI Symbol Length MULTSYM 0 to 1 0 Multiple Symbol mode NO_...

Page 82: ...onds UE1ENAB 0 to 1 0 Enable UPC E1 Decoding UPADEFA Default UPC A parameters UPAENAB 0 to 1 1 Enable UPC A Decoding UPAXMIT 0 to 1 1 Transmit UPC A Enable Check digit UPEDEFA Default UPC E parameters...

Page 83: ...JADAK flexpoint HS 1M User s Manual Page 82 Appendix B Programming Chart After you re done with setting the value with the barcodes above finish with scanning SAVE...

Page 84: ...nction code 1 in first symbol character position 2 Function code 1 in second symbol character position Example A Code EAN 128 bar code with Function 1 character FNC1 in the first position AIMID is tra...

Page 85: ...idated and stripped check digit Example An I 2 of 5 bar code without check digit 4123 is transmitted as I04123 PDF417 Macro PDF417 Micro PDF417 L 0 Reader set to conform to protocol defined in 1994 PD...

Page 86: ...S 0 No options specified at this time Always transmit 0 Example A D 2 of 5 bar code 4123 is transmitted as S04123 Maxicode U 0 Symbol in Mode 4 or 5 1 Symbol in Mode 2 or 3 2 Symbol in Mode 4 or 5 EC...

Page 87: ...nt HS 1M User s Manual Page 86 Appendix D ASCII Conversion Chart For these HS 1M engines use 2 digit Hex values to create an ASCII character E g to create an F use 46 and to create an f use 66 Use 7A...

Page 88: ...JADAK flexpoint HS 1M User s Manual Page 87 Appendix D Cont d ASCII Conversion Chart...

Page 89: ...JADAK flexpoint HS 1M User s Manual Page 88 Appendix E Sample Bar Codes UPC A Codabar Code 128 Code 39 Code 93 Interleaved 2 of 5 PDF 417 Composite Code MicroPDF Aztec Data Matrix QR Code MaxiCode...

Page 90: ...7279 William Barry Blvd Emmastraat 16 North Syracuse NY 4811 AG Breda 13212 3349 The Netherlands Phone 1 315 701 0678 Phone 31 0 76 522 5588 Fax 1 315 701 0679 Fax 31 0 76 522 4747 e mail info jadakt...