IA-3126-2

User Manual

16 Relays
16-ch Wide-Range inputs
IA Daisy-chain Series

Version 0213

www.intelligent-appliance.com

Summary of Contents for IA Daisy-chain Series

Page 1: ...IA 3126 2 User Manual 16 Relays 16 ch Wide Range inputs IA Daisy chain Series Version 0213 www intelligent appliance com...

Page 2: ...e com We at Intelligent Appliance highly value your opinion Please feel free to contact us with your impression on any subject or with any question you may have Copyright 1985 2013 Intelligent Applian...

Page 3: ...elays status Activate relay N Deactivate relay N Set device mode Set baud rate Set module s address Set initiate State Set LED Status Set initiate State at all modules 4 5 6 7 8 9 10 11 12 13 14 15 16...

Page 4: ...Range inputs IA Daisy chain Series Intelligent Appliance The IA 3126 2 is an indutrial intelligent 16 ch Relay Control Board with 16 ch Digital Input and multi drop operation capability in the origin...

Page 5: ...orm A 5V to 30VDC 16 Dry contact RS 232C Daisy chain 19200 8 n 1 DB9 Female DB9 Male DB9 M F pin to pin 3 wires pin2 3 and 5 up to 15m long DB9 M F pin to pin 3 wires pin2 3 and 5 up to 15m long 24 VD...

Page 6: ...Device Host PC DB9 Female DB9 Female DB9 Male 255 DB9 Female IA 3126 2 Specifications subject to change without notice 16 Relays 16 ch Wide Range inputs IA Daisy chain Series Intelligent Appliance 6 w...

Page 7: ...2 Specifications subject to change without notice 16 Relays 16 ch Wide Range inputs IA Daisy chain Series Intelligent Appliance 7 L D 1 U s e r g e n e r a l u s e L E D T B 9 Power Supply Input Term...

Page 8: ...he IA 3126 Relays controller includes 16 Wide Range Digital Inputs that might be used as Dry Contact Inputs Two Jumpers JP2and JP3 each controls input voltage range of correspondenly inputs 1 8 and 9...

Page 9: ...list that appears beneath the Search button Once the device is selected its form will be shown in the right hand of the screen Left clicking the buttons will activate or disactivate the appropriate re...

Page 10: ...to change without notice 16 Relays 16 ch Wide Range inputs IA Daisy chain Series Intelligent Appliance 10 a a 0 a a 1 a a 2 a a 5 a a I D a a S a a 2 d d d d a a 3 d d a a 4 d d a a 5 d d a a 6 B B a...

Page 11: ...iter NNNN A string containing the device name cr Carriage Return end of response Command 010 cr Response _3126 cr Request the device at address 01Hex to send its model name The response indicates that...

Page 12: ...evice version cr Carriage Return end of response Command 001 cr Response _A125 cr Request the device at address 00 Hex to send its version The response indicates that the command was successful and th...

Page 13: ...nibble C 3rd input nible D 4th input nible E 1st output nible F 2nd output nible G 3rd output nible H 4th output nible Command 002 cr Response _00018001 cr Input 1 is Active and both relays 1 and 16 a...

Page 14: ...e stauts of JP1 and the LED aaS cr Delimiter character aa Hexadecimal address of the device S Read Jumper LED Status cr Carriage Return End of command _DD cr if the command was valid where D is _ Deli...

Page 15: ...e command was valid Command 005 cr Response _82 cr In this example the module operation mode enables baud rate change It will also send error messages for invalid commands aa5 cr Function Description...

Page 16: ...evice ID This command reads the Device ID aaID cr Delimiter character aa Hexadecimal address of the device ID Command for read ID cr Carriage Return End of command _ID NNNNNNNN cr Command 00ID cr Resp...

Page 17: ...hex format cr Carriage Return End of command DDDD cr if the command was valid and if FB messages are enabled Command 0021111 cr Response 1111 cr This command will activate relay 1 5 9 13 aa2DDDD cr F...

Page 18: ...cr Delimiter character aa Hexadecimal address of the module 3 Single relay activation command DD N Relay ID in hex format cr Carriage Return End of command SDD cr if the command valid Command 00302 cr...

Page 19: ...D cr Delimiter character aa Hexadecimal address of the module 4 De activate relay N command DD Relay ID hex format cr Carriage Return End of command CDD cr if the command valid Command 00402 cr Respon...

Page 20: ...es are sent in response to invalid commands and will disable baud rate changed by mistake aa5DD cr Function Description Syntax Response Example IA 3126 2 Specifications subject to change without notic...

Page 21: ...of command BB cr if the command was valid Response delimiter BB New Baud Rate cr Carriage Return end of response Command 01696 cr Response 96 cr Change the baud rate of the device at address 01Hex to...

Page 22: ...nd defines a module s address Factory default is 00Hex aa7AA cr Delimiter character aa Hexadecimal address of the device 7 Get device Version command AA New Hexadecimal address cr Carriage Return End...

Page 23: ...dress of the device E System control command D Relay output activation command data for each nibble in hey format cr Carriage Return End of command EDDDD cr if the command was valid Command 00EFFFF cr...

Page 24: ...ON or turnes OFF the LED aaSDD cr Delimiter character aa Hexadecimal address of the device S Set LED Status D LED Status 1 On 0 Off cr Carriage Return End of command 0D if the command was valid Comman...

Page 25: ...Force Initiate State At All Modules This command forces all modules of this net into their pre defined initiate state E cr Delimiter character E Force initiate state command cr Carriage Return End of...