Page 1: ...ISO 9001 CERTIFIED 607 NW 27th Ave Ocala FL 34475 Phone 352 629 5020 or 800 533 3569 Fax 352 629 2902 SUITABLE FOR EXTERNAL DISTRIBUTION Intelli Tank Level 40 OPERATION MANUAL...

Page 2: ...n 10 3 3 7 Invalid calibration 10 3 3 8 Calibration incomplete 11 3 4 SELF TEST 11 3 5 SETTING THE DIM LED LEVEL 11 3 6 SHOW SOFTWARE VERSION DEVICE SETTINGS AND ERRORS 11 3 7 CONFIGURE THE COMMUNICAT...

Page 3: ...STERS and 2 REMOTES 21 6 3 3 CAN method 1 MASTER and 2 REMOTES 22 6 3 4 CAN method 2 MASTERS and 2 REMOTES 22 6 3 5 Terminating resistor requirement CAN communication 23 6 4 COMMUNICATION COMPATIBILIT...

Page 4: ...4 of 27 DATE 6 12 2019 PRODUCT GROUP ITL40 P N 118404 XX REV 1 30 PRODUCT Intelli Tank Level 40 BY AMS MANUAL P N 118253 PRINTED 6 12 19 1 Revision Log Rev Date Approved Changes 1 00 9 24 2008 AGK In...

Page 5: ...04 123340 04 Green LEDs p n 118404 05 123340 05 Blue LEDs p n 118404 06 123340 06 2 Red 2 Yellow 2 Blue 2 Green rows of LEDs Labels C1 p n 117691 water blue p n 117692 foam red p n 117693 foam green...

Page 6: ...3 1 LED indications The ITL40 display uses 8 rows of LEDs to show the unit status tank level indication section 3 1 2 and error indications section 3 1 3 3 1 1 Initial power ON indications When the I...

Page 7: ...l 40 BY AMS MANUAL P N 118253 PRINTED 6 12 19 3 1 3 Error indications Condition Visual Condition Visual Invalid calibration NO DATA REMOTE is not receiving data from MASTER Incomplete calibration Pass...

Page 8: ...mall o to indicate the location of the magnetic switch For best results the magnet should be positioned over the desired switch approximately 2 inches from the front of the display pushed directly to...

Page 9: ...ection 3 1 3 on the next power cycle 3 3 1 1 Point Calibration 1 point calibration only calibrates the full point The empty calibration is always set to 0 55V approximately 1 5 inches of liquid 1 Make...

Page 10: ...then activate the RIGHT switch The display will flash the top two LED rows and then begin scrolling the text SET 1 4 4 Fill the tank to the one quarter point and then activate the RIGHT switch The di...

Page 11: ...ommunication wire test WIRE PASS Data communication lines good WIRE FAIL Data communication lines shorted or open If the self test password is used on a MASTER display all REMOTE displays will also pe...

Page 12: ...CAN communication method is new for the ITL40 displays and is a more robust communication method This method requires two wires CAN high CAN low and approved J1939 CAN wiring and connectors There sho...

Page 13: ...Q R S T U V W X Y Z SP 0 1 2 3 4 5 6 7 8 9 Enter the password LLLL LRLR and the display will show the first available character A Use the LEFT and RIGHT magnetic switches to enter the desired text Th...

Page 14: ...causes the fluid to slosh producing significant fluctuation in the displayed tank level The ITL40 can counteract these conditions by averaging the rhythmic changes sloshing detected by the pressure s...

Page 15: ...e feature has been enabled 3 11 2 Disabling the AutoFill output Disable the AutoFill feature by entering the password LRRL RLLR The display will scroll FILL OFF to indicate that the feature has been d...

Page 16: ...n 3 7 3 LRRR LRRR Configure as Master display with CAN address 3 section 3 7 3 LRRR RLLR Configure as Master display with CAN address 4 section 3 7 3 LRRR LRLR Configure as Master display with CAN add...

Page 17: ...k section 3 8 RRRL LLRR Configure AutoFill turn on for 3 8 Tank section 3 8 RRRL LRLL Configure AutoFill turn on for 1 2 Tank section 3 8 RRRL LRLR Configure AutoFill turn on for 5 8 Tank section 3 8...

Page 18: ...18 of 27 DATE 6 12 2019 PRODUCT GROUP ITL40 P N 118404 XX REV 1 30 PRODUCT Intelli Tank Level 40 BY AMS MANUAL P N 118253 PRINTED 6 12 19 5 Installation 5 1 Cutout dimensions The display requires a c...

Page 19: ...0 BY AMS MANUAL P N 118253 PRINTED 6 12 19 5 3 Label orientation Before mounting the display and adhering the label insure that the display is situated correctly TOP is UP Refer to the drawing for ori...

Page 20: ...IELD DATA SAE J1939 CAN 2 0B 250Kbits s 4 DIM DISPLAY INPUT Dim display input positive polarity 5 Sensor REF OUTPUT pressure sensor supply 5VDC 6 Sensor SIGNAL INPUT pressure sensor signal 0 5VDC to 4...

Page 21: ...The simplest system would be comprised of a single ITL40 MASTER display 6 3 1 1 wire method 1 MASTER and 2 REMOTES System configured with 1 wire communication method Make certain that the ground for...

Page 22: ...communicating with 2 REMOTE displays configured with address 1 Two CAN terminating resistors p n DT06 3S P006 are required in the system one at each end of the CAN bus 6 3 4 CAN method 2 MASTERS and 2...

Page 23: ...nating resistor p n DT06 3S P006 CAN 3 way Y connector p n DT04 3P P007 6 4 Communication compatibility with Class 1 products The ITL40 display is compatible with other Class 1 CAN and 1 wire products...

Page 24: ...ise recalibrate or reset as REMOTE Outer two LED rows alternate flashing Invalid calibration Try to recalibrate If condition remains check if the sensor signal voltage pin C changes as tank level incr...

Page 25: ...have changed No picture Check the pressure sensor for problems Recalibrate the display and take a voltage reading from the sensor pin 6 on the display s connector at each calibration point When the ca...

Page 26: ...g flammable liquids where blanketing or smothering effect of water is of prime importance in extinguishing gasoline etc IP Ingress Protection IP 67 etc ITL Intelli Tank Level Class 1 s 4 and 5 light t...

Page 27: ...to SAE J1113 specification for heavy duty trucks Transient voltage protected to SAE J1113 specification for heavy duty trucks Dimensions W x H x D in inches mm 3 185 80 90 x 5 125 130 17 x 2 150 54 6...

Page 28: ...nated biphenyls PBB and polybrominated diphenyl ethers PBDE in electrical and electronic equipment Parts TOXIC AND HAZARDOUS SUBSTANCES OR ELEMENTS Pb Hg CrVI PBBs PBDEs Cd Base O O O O O O Box O O O...