Summary of Contents for JY Series

Page 1: ...JY JYS TANK RANGE COLUMN AQUARIUM INSTRUCTION MANUAL ...

Page 2: ......

Page 3: ...ter installation This should not be plugged in if there is water on parts that are not intended to get wet Do not operate the unit if the plug or cord is damaged if it is malfunctioning or if it has been dropped or damaged in some way Do not yank cord to pull plug from outlet Grasp the plug and pull to disconnect Always unplug from an outlet when not in use The power cord of this appliance cannot ...

Page 4: ... from the wall socket and consult All Pond Solutions or the retailer you purchased this unit from for further advice CAUTION NEVER place any object s on the LED strip light Make sure there is adequate air space around the light The safety and correct functioning of your aquarium is only guaranteed if the lighting and all other equipment has been correctly installed Ensure supplied powerhead is ful...

Page 5: ... that these are suitable for INDOOR USE ONLY For fresh and saltwater aquariums with a maximumwatertemperature of35 C do not setup orstore the tank in anylocation where temperatures maydrop belowfreezing ELECTRIC This aquarium comes complete with a generous supply of 3 core cable however should any additional cable be required the use of an approved waterproof cable connector with a proper rating i...

Page 6: ... 1 Inspect the acrylic tank for any damage or cracks 2 Following your visual inspection if it does not show any damage fill your tank with 5cm 2 of water wait 10 minutes and test for leaks 3 Add another 5cm 2 and repeat this process until you are sure there is no sign of any leak 4 If no leak is identified continue with the normal aquarium set up Always handle your tank with the utmost care Make sur...

Page 7: ...to help regulate and maintain a suitable temperature Do not locate your aquarium in a location or on a surface where water spills will cause damage Position your aquarium close to an electrical outlet Make sure that your chosen location for your aquarium has an even and level surface which will be able to support the total weight of the aquarium and cabinet when filled with water Once the tank is p...

Page 8: ...o balls Water filter pump Air pump Glass cover Top filter tray spray bar T piece for air pump Non return valve Inlet strainer LED light unit Venturi pipe Water outlet for filter Flexi pipe for pump to filter Filter box lid Heater Clear hard tube ...

Page 9: ...e tank will need to be cut a few centimetres down and connect to the non return valve put the black end closest to the air pump Connect the water filter pump 3 to the clear hard tube 16 and then attach the strainer 9 to the bottom of the tube The black flex pipe 13 attaches to the top of the water pump and then feeds through a hole in the top of the tank rim Slide on the back plate and position on t...

Page 10: ...rubber end piece must sit in the groove on the right hand side in order to connect to the flex pipe 13 Sit the filter box lid 14 on top of the top filter tray Carefully lay the glass cover 5 onto the top of the tank rim Position the filter trays and the LED light unit 10 on top of the glass cover Ensure that the protective plastic wrap cover has been removed Position the switch and all cables to hang ...

Page 11: ...tor Stems sideways as this may damage the output input systems and the glass tank IMPORTANT All Pond Solutions always advises fish keepers to cycle aquarium water for at least 2 4 weeks before adding any type of fish to a new setup This allows adequate time for your filter system to circulate properly and water readings to stabilise if fish are added prior to this it is highly likely they will suffer T...

Page 12: ...ace Ceramic Shaft Clean Inspect Replace All Pipework Clean Inspect Hosing Clean Inspect Heater Clean Inspect O Rings Clean Inspect Lubricate Clean Replace Floss Foams Other Media Clean Inspect Replace It is important to regularly clean and replace the floss filter foams provided to avoid water blockages and ensure sufficient water flow through the filter ...

Page 13: ... limescale build up Rinse thoroughly afterwards to remove any acidic residue It is vital that O rings are regularly inspected and replaced as the rubber watertight seal will perish over time which may cause your canister to leak Before replacing your o rings ensure they are well lubricated O rings A clogged impeller is often the primary cause of many operational faults so it is extremely important...

Page 14: ...M MEDIA TRAY Filter Floss Foam Bio Balls Mechanic Filtration Biological Filtration Removes small waste particles from the water Creates environment for nitro bacteria to cultivate and help oxygenate the water TOP MEDIA TRAY Filter Floss Foam IMPORTANT Always use water from your fish tank to clean your filter media Do not use mains water or any cleaning products to clean your media Please remember to...

Page 15: ... commences from the date of purchase This guarantee is valid with proof of purchase only If you require support on how to use your aquarium replacement parts or if your tank develops a fault during the warranty period please contact the supplier of your aquarium Non replaceable non perishable and non serviceable parts will be repaired or replaced free of charge once the unit is returned with all c...

Page 16: ...It does not apply to units which have been assembled incorrectly improperly maintained or where the instructions and safety information in this manual has not been followed correctly This guarantee is only valid under standard operating conditions for which the unit is intended Before returning your unit under warranty terms check that all setup and maintenance instructions have been correctly fol...

Page 17: ......

Reviews: