HOSHIZAKI

SELF-CONTAINED CUBER

 

MODEL

   

IM-65LE-Q

SERVICE MANUAL

Summary of Contents for IM-65LE-Q

Page 1: ...NO E1AH 806 ISSUED MAY 8 2010 REVISED HOSHIZAKI SELF CONTAINED CUBER MODEL IM 65LE Q SERVICE MANUAL ...

Page 2: ...GRAM 2 3 DIP SWITCH SETTING 3 4 SERVICE DIAGNOSIS 4 5 ADJUSTMENT OF MICRO SWITCH 5 This service manual provides specific information for IM 65LE Q only For any other information please refer to the service manual for the standard model IM 65LE i ...

Page 3: ...ating position ACM and CM stop State 4 When water plate releases ice WV closes and water plate starts to open further State 5 When water plate fully opens and S1 moves to left arm down position HV opens When 3 minutes passes after CM stops in state 2 CM restarts State 6 Cube control thermistor senses temperature higher than defrost setting water plate starts to close and water supply begins State ...

Page 4: ...2 2 WIRING DIAGRAM ...

Page 5: ...3 3 DIP SWITCH SETTING Dip Switch No Volume Setting Freeze VR DSW 1 A Defrost VR DSW 2 4 Dimple Range DSW 3 4 Water Supply DSW 4 0 Code Setting 1 DSW 5 9 Code Setting 2 DSW 6 7 ...

Page 6: ...model IM 65LE PROBLEM POSSIBLE CAUSE REMEDY 1 Deformed ice a Water Pan Lower Evaporator 1 Upper and Lower Evaporators not aligned 1 Readjust b Lower Evaporator 1 Coating damaged removed or worn 1 Replace 2 Cam Arm will not stop at a proper position a Micro Switch A 1 Open circuit or moisture inside 1 Replace b Micro Switch B 1 Open circuit or moisture inside 1 Replace ...

Page 7: ...tuator by pushing up the lever too much 3 After adjustment check for proper operation To adjust the Micro Switch B 1 Push the loosely fit Switch Bracket fully to the left 2 Turn the Actuator Motor Arm to position the roller of the Micro Switch B as shown above 3 Push the Switch Bracket fully to the right until the Micro Switch B trips with a click sound Then lock the Switch Bracket in that positio...