GENERAL INFORMATION 

The ADEMCO 6160PX is an addressable Remote Keypad with a built-in Proximity Reader, and is intended for use 
with ADEMCO control panels.  

 

Basic features of the Keypad 

 2-line Alpha display 

  Backlit Display (programmable as permanent on 

some controls; see the control's instructions for 
details) 

  Continuously Backlit Keys for convenience 

  Programmable Function Keys 

 Built-in Sounder (speaker) 

  Arm/Disarm via Prox Tag 

  LED Indicators for Armed and Ready-To-Arm 

  Supervised by control panel (if supported) 

  Uses two keypad addresses 

Installation Notes 

 

The Keypad can only be used on addressable systems 
and must be set for address 00-30 (16-23 for 
VISTA-15P / VISTA-20P and VISTA-21iP controls). 

 

The Prox Reader uses an additional keypad address, 
which must be enabled at the control panel (see 
control panel installation instructions for allowable 
keypad addresses). 

 

The partition used for the Keypad, Prox Reader, and 
user security code must be the same. 

 

The Prox Tags will only arm and disarm one 
partition. The Prox Reader cannot be used to perform 
global arming operations. 

 

For optimal performance, use only the Prox Tags 
provided. For additional Prox Tags, order 
PROXTG-BK (Black) or PROXTG-GY (Gray). 

MOUNTING AND WIRING  

The Keypad can be surface mounted directly to a drywall, or to a single- or double-gang electrical box. 

1.  Push the two case release snaps at the bottom of the Keypad 

with the blade of a medium screwdriver, then pull that side 
of the case back away. Insert the screwdriver in the side of 
the Keypad (between the front and back case) and gently 
twist to release the side locking tab. Repeat for the other 
side. Refer to Figure 1 for location of the case back release 
snaps and locking tabs. 

2.  Route wiring from the control panel through the opening in 

the case back. 

3.  Mount the case back to a wall or electrical box.  

4.  Wire directly from the Keypad’s terminal block

 

to the 

terminal block on the control panel. (See Wiring Table 
below). 

Connect only the red and black Aux. Power 

connections at this time. 

 

Do not connect the ECP Data In or Data Out until directed 
to do so. If the keypad’s Prox Reader detects the presence 
of ECP Data In and Out connections during address 
programming mode, it will exit to “normal” mode.  

 NOTE:

 No more than one wire per terminal may be 

connected. If daisy-chained configuration is required, pigtail 
wires together so that only one wire is terminated under the 
screw. Use 16-24 AWG wire only!

 

 

NOTE:

TO REMOVE CASE BACK
PUSH IN THE TWO MOUNTING
SNAPS LOCATED ALONG THE 
BOTTOM OF THE KEYPAD
AND LIFT UP.

6150-006-V0

RETAINING

SNAPS

ARMED

READY

LOCKING

TAB

 

 

Figure 1. Removing the Case Back 

 

Wiring Table  

Keypad Control 

Panel 

Wire 

Color 

G

 

Data In

 

Green

 

 

– Aux Pwr (GND)

 

Black

 

+

 

+ Aux. Pwr

 

Red

 

Y

 

Data Out

 

Yellow

 

See the control panel’s Installation and Setup Guide for 
more complete details. 

 

5. Reattach the Keypad

 

to its case back. 

6.  If the Keypad and Prox Reader addresses have not yet been programmed, refer to the Setting the Keypad and 

Prox Reader Addresses section and set the two addresses. 

7.  After the Keypad and Prox Reader addresses have been programmed, remove the Keypad from its back plate 

again (see step 1 above) and connect the green and yellow (data in/data out) wires from the control.  

8. Reattach the Keypad

 

to its case back. 

Summary of Contents for Ademco 6160PX

Page 1: ... of the case back away Insert the screwdriver in the side of the Keypad between the front and back case and gently twist to release the side locking tab Repeat for the other side Refer to Figure 1 for location of the case back release snaps and locking tabs 2 Route wiring from the control panel through the opening in the case back 3 Mount the case back to a wall or electrical box 4 Wire directly f...

Page 2: ...own power up and start address mode again Defaults Keypad address 31 Prox Reader address 23 Keypad Address Mode 1 Enter keypad address mode Power up the Keypad Immediately press and hold down the 1 and 3 keys at the same time for 3 seconds If unable to enter address mode power up and try again The current keypad address is displayed and the cursor will be under the tens digit If only the red and b...

Page 3: ...DE 0 3 STAY 6BYPASS ARMED READY 9CHIME A B C D SPEAKER LCD DISPLAY PRESENT PROX TAG HERE LEDS 6160PX 001 V0 FUNCTION KEYS Programmable Function Keys The keypad features function keys that may be programmed for panic alarms or other special functions such as macros See the control s instructions for details Function Keys Equivalent Key Pairs A 1 and B and C 3 and D NONE Function keys must be held d...

Page 4: ...terference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is ...

Reviews: