background image

1

 

 

 

Instruction Manual

 

 

 

IP55 

rating 

cover for

 

TP

-

A1 

keypad

 

“CTP

-

A1”

 

 

 

 

 

 

 

 

Thank you very much for purchasing the

 

optional

 

IP55 rating cover “CTP

-

A1” for TP

-

A1

-

XXX 

keypad

.

 

This  manual

 

describes  the  installation  procedure

 

of  this  optional  cover

.

 

By  installing  this  cover  with  the

 

TP

-

A1

-

XXX 

keypad

 

in 

the

 

external  surface  of  a  switch  cabinet,  the  keypad  is  protected  from  dust  and  water 

splash, achieving IP55 ingress protection rating.

 

 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

 

 

Read  through  this  manual

 

in  conjunction  with  the  instruction  manual

 

of  FRENIC  HVAC,  FRENIC  AQUA,  FRENIC  Lift, 

FRENIC Ace inverters and TP

-

A

-

XXX 

keypad

,

 

to become familiar with proper handling and correct use.

 

 

Improper 

installation may result in not fulfilling IP55 rating. Please follow the installation procedures written in this manual.

 

 

This cover can be used only in combination with TP

-

A1

-

XXX 

keypad

. Do not attempt to use with 

other types, even from Fuji 

Electric.

 

 

Deliver this manual

 

to the end user of t

his product.

 

 

Failure to heed the information described in this manual may lead to a loss of any liability by Fuji Electric Europe GmbH.

 

 

 

 

 

Fuji Electric Europe GmbH

 

 

 

 

 

 

      

IM

-

FEE

-

CTPA1

-

1001a

-

EN

 

 

 

Summary of Contents for TP-A1

Page 1: ...nction with the instruction manual of FRENIC HVAC FRENIC AQUA FRENIC Lift FRENIC Ace inverters and TP A XXX keypad to become familiar with proper handling and correct use Improper installation may res...

Page 2: ...e cover as shown in figure 1 Figure 1 CTP A1 cover appearance The cover has no apparent cracks or any deformation 4 fixing screws are already placed in the 4 fixing holes of the cover as shown in figu...

Page 3: ...the panel Please refer to figure 2a below 2a Installation holes marked 2b Installation holes drilled Figure 2 Making the installation holes 3 Drill the holes according to the diameters and tolerances...

Page 4: ...t interferes with the upper side of the keypad Then fasten completely the 2 fixing screws as shown in figure 4 below Check that the keypad does not fall apart Figure 4 Fastening the 2 screws of the up...

Page 5: ...be hardly seen as shown in figure 6b below The screws provided are suitable for a panel door thickness up to 2 mm For panels thicker than 2 mm please consult with Fuji Electric representative 6a Fixin...

Page 6: ...6 Annex Installation holes drawing...

Page 7: ...e found or any suggestions you may have for generally improving the manual In no event will Fuji Electric Europe GmbH be liable for any direct or indirect damages resulting from the application of the...

Page 8: ...8 Fuji Electric Europe GmbH Goethering 58 63067 Offenbach am Main Germany www fujielectric europe com info inverter fujielectric europe com...

Reviews: