SLIDING GATE OPENER CONTROL BOARD SL16XX USER MANUAL

       

A7 

I Safety Instruction

 

1.

 

For security, please read instructions carefully before initial operation; making sure that the power is off before connection. 

2.

 

Please clear the memory before initial operation. 

(Ref.: Erasing ALL learned/memorized Transmitters

 

3.

 

Do not learn the remote control when motor is operating in order to avoid mis-operation. 

4.

 

The received signal may be interfered by other communication devices. (e.g. the wireless control system with the same frequency range) 

5.

 

It is forbidden to control the high-risk coefficient equipment / system. (e.g. cranes) 

6.

 

It  is  used  only  for  the  manual  remote  control  and  wireless  control  equipment  /  system  which  must  not 
endanger life or property during running failure, or its security risks have been eliminated. 

7.

 

It should be applied in dry indoor place or in the electric appliance place. 

II Technical Index 

1.

 

Working voltage: 220VAC/110VAC

50Hz/60HZ 

2.

 

Temperature range: -20

  to 60

 

3.

 

Loading capacity: 1HP, 250VAC 

4.

 

Built-in fuse: 10A, please exchange appropriate fuse according to loading capacity 

5.

 

Time of Soft-start & soft-stop: 4S/6S 

6.

 

Operation time: adjustable from 10S to 130S 

7.

 

Working frequency: 433.92MHz 

8.

 

Transmitters stored:

 

30 -300PCS 

9.

 

Size : 150*77*38

 

10.

 

Weight

301g

 

III    Wire connection   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IV Set up 

4.1 Learning transmitters

Press the learning button, LED is on, enters into the learning / memorizing transmitter process; Press the same button 

twice, LED blinks for several times, then off. The learning process is successful. (Ignore this step if transmitter already matches the opener before 
delivery): 
4.2 Erasing transmitter: Press the learning button, continue pressing for 8s until LED turns off; Release learning button, LED will be on (about 1s) 
and then off; the erasing process is successful. (Ignore this step if transmitter already matches the opener before delivery) 
4.3 Opening/closing limit adjustment: Remote control the door ( or move the door manually ) , adjust the position of limit device to make sure the 
door would touch the limit switch when open or close the door .LED LD5/DL6 in the controller will be off when limit device touches limit switch 
4.4 Running time/waiting time adjustment: « Adjust potentiometer T. Normal to change the running time (10-130s) of motor .Adjust it to make the 
running time slightly longer (1-2s) than opening time that it needs. Adjust potentiometer T. Wait to change the time that between door opening to 
auto-closing(10-130s).This function is available when DIP 1 is at ON position .   
4.5 Photocell protection function test: Photocell connector connects the NC contact of photocell switch , DL7 LED turn on after the connection, And 
DL7 LED turn off when blocking out the transmit or receive signal of photocell artificially   
4.6 DIP Switch set

   

 
 

As shown: 
A:

1\2\3\4

For  working  voltage 

220VAC\110VAC

 

B:

5\6

Connector for flash lamp 

C: 

8

Connector for motor common 

port  1; 

7

Connector  for  motor 

running  port  1;

9

Connector  for 

motor running port 2. 
D: 

7/9

Connector for motor starting 

capacitance. 

As shown: 
A:

12\13

Connector for photocell 

protection switch NC contact 

B:

10\11

24VAC output can power 

supply the photocell. 

C:  If  no  need  of  using  photocell, 

make connector

12\13

short 

circuit  with  terminated  line(the 
connector  is  short  circuit  when 
leave factory) 

 

As shown: 
DIP switch 2 in 
OFF position, 
connector

14\15\16

for 

limit switch is 
Normal Open 

 

As shown: 
DIP switch 2 in 
ON position, 
connector

14\15\16

for 

limit switch is 
Normal Close

  

 

As shown: 
Connector 

【17\18\19\20\21】

 

for external 
close/stop/open/loop control, 
control systems is the same as 
using transmitter

 

 

DIP2

 

ON

External limit NC switch 

OFF

External limit NO switch 

DIP3:

 

ON  or  OFF  can  change  the  current 

operating 

direction 

of 

motor 

(opener can be chosen to install on 

right side or left side of the door) 

DIP1:

 

ON: Auto-close is effective 

OF: Auto-close is off 

DIP4:

 

ON

Three button control 

OF

Single button control 