background image

Hager witty park XEV6xx

6LE002957B

6LE002957B

 

1

z

Installation manual

1. Initial precautions

Please refer to the maintenance manual before starting the installation of the charging station. The device is to be installed only by a professional electrician 

fitter according to local applicable installation standards. Conform to SELV installation rules.

2. General description

Strip light
RFID Card Reader

Socket: Mode 3 Type 2S

Socket: Mode 2 

Optional:

 integration of a modem

Energy meter (version-specific)

The outer casing can be removed 

by unscrewing two screws

Optional:

 base

Optional integration of a protective casing

Summary of Contents for XEV426

Page 1: ...be installed only by a professional electrician fitter according to local applicable installation standards Conform to SELV installation rules 2 General description Strip light RFID Card Reader Socket Mode 3 Type 2S Socket Mode 2 Optional integration of a modem Energy meter version specific The outer casing can be removed by unscrewing two screws Optional base Optional integration of a protective ...

Page 2: ...prises the following parts Contact detection fixed on the contactor Controller MID energy meter version specific Grommet plate Controller power supply Terminal blocks 3 M3T2S socket lockable 1 M3T2S socket lockable 4 M2TE socket 2 M2TE socket Circuit breakers Power contactors TCP IP Board version specific 2 ...

Page 3: ...6LE002957B 4 Attachment and connection a Diagrams for wall drilling without wiring space at the rear 713 765 1300 max 480 330 2 0 2 355 233 87 50 1395 max 235 4x not included ø 1 1 3 ...

Page 4: ...6LE002957B b Diagrams for wall drilling with wiring space at the rear for XEV427 713 765 480 330 2 0 2 355 1300 max 233 87 50 1395 max 435 235 ø 8 5 54 4x not included 2x 2x XEV427 4 ...

Page 5: ...V428 Terminal Installation Area 1472 1239 1089 2 0 2 1 7 5 355 175 110 325 650 325 70 350 250 190 250 500 250 Foundation C20 25 X0 Depth 80 cm Bedding Layer 5 cm C8 10 XEV426 In case of a chemical seal use threaded rods with diameter of 12 mm XEV428 5 ...

Page 6: ...7B The terminal MUST be mounted on its base BEFORE attaching the vector cabinet The equipotential bonding must be established between the terminal foot and base O 6 Earthing point to connect to the earth system ...

Page 7: ...e power wait for 15 seconds and then change the position of the encoder wheel to an authorised threshold Then turn on the terminal a steady green light should light up X1 1 2 N Three phase power supply 1 X1 X2 Controller power supply MZ203 Trigger circuit connection X3 Three phase power supply 2 X3 X4 L1 L2 L3 N L1 L2 L3 N LST N N LST L1 X0 1 X0 X0 3 X2 3 4 MZ203 trigger circuit connection X1 Wiri...

Page 8: ...ype A 40 A C curve 30 mA type A 40 A C curve 30 mA type B 40 A C curve 30 mA type B protections for the controller supply protections for the controller supply protections for the controller supply protections for the controller supply protections for the controller supply 8 MZ203 MZ203 MZ203 ...

Page 9: ... TN or TT neutral point connection OK neutral point connection neutral point connection neutral point Max 50 Ω Max 50 Ω for the 5 stations Max 5 stations on 1 earthing connection Interconnection Electrical cabinet Station Protection integrated in the electronic board Power 4 kVA only MZ203 transmitter coils Fault detected Information via solid red indicator light for 3 seconds Disconnection from n...

Page 10: ...lse Factory setting depending on the meter of sockets 3 and 4 Network_failure 0 1 0 Restricted access with recognised badges 1 Free access with compatible badges Access type in the absence of a network connection for a terminal managed by OCPP Access control 2 Name N caractères Nom de la borne en local MMI_type 1 1 Single LED Factory setting DN_mode 0 1 2 0 Start up via external 230 VAC signal 1 P...

Page 11: ... http address of the OCPP server Depending on OCPP server configuration client Not active cpref N characters Terminal name seen from the OCPP server Default MAC address AttachedCable 0 1 Jumper cable Attached cable Based on OCPP server configuration c Access control Modify the b1237 global cfg file Whitelist Declaration of users max 250 who can start and stop their charging session Superuser Decla...

Page 12: ...C1 and C2 C1 C2 Creation modification of a whitelist or a super user from the file Retrieve the b1237 badges txt file by inserting a blank USB key and rename it b1237 whitelist txt You can then directly add the corresponding badge numbers in the file in the correct order of the fields without erasing the old numbers The b1237 whitelist txt file must contain all badge numbers After modifying the fi...

Page 13: ...ad management signal to the station s PINs 50 and 51 Edit the b1237 global cfg file as follows System y Pin 50 and 51 If 1 Partial charging override If 2 Full charging override Note in this case any charge that has started will stop as soon as the external 230Vac signal appears and will resume if it disappears y o PIN ...

Page 14: ...olerance standard Flashing red 6x cycle Fault Defective communication between station and EV earthing fault earthing is cut but CP is looped via Neutral Flashing red 6x cycle Fault Defective communication between station and EV diode error connection to something other than an EV Flashing red 6x cycle Fault Invalid badge Rapidly flashing red Fault Charging rate on 6A in single phase Solid red Faul...

Page 15: ...unication 3 Electric vehicle is overcharged The EV does not comply with the power limit set by the station 4 Ventilation required The vehicle requires additional ventilation the charging is blocked 5 Fault in charge management The load shedding is too frequent during charging 4x and the power supply to the house is not sufficient 6 Defective communication Defective cable problem at the diode Fixed...

Page 16: ...lation standards Conform to SELV installation rules Usable in all Europe M and in Switzerland Correct Disposal of this product Waste Electrical Electronic Equipment z Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household waste at the end of its ...

Reviews: