Powerturn

Valid for variants:
Powerturn (1-leaf/2-leaf)
Powerturn F (1-leaf)
Powerturn F-IS (2-leaf)
Powerturn F/R (1-leaf/2-leaf)
Powerturn IS/TS (2-leaf)
Powerturn F-IS/TS (2-leaf)
Powerturn F/R-IS/TS (2-leaf)

Original operating instructions
EN   User  manual

156539-03

Summary of Contents for Powerturn (1-leaf)

Page 1: ...ts Powerturn 1 leaf 2 leaf Powerturn F 1 leaf Powerturn F IS 2 leaf Powerturn F R 1 leaf 2 leaf Powerturn IS TS 2 leaf Powerturn F IS TS 2 leaf Powerturn F R IS TS 2 leaf Original operating instructions EN User manual 156539 03 ...

Page 2: ...perating modes display 8 3 4 2 Mechanical programme switch MPS optional 9 3 4 3 Display program switch optional 9 3 5 Door in normal operation 10 4 Operation 11 4 1 Selecting the mode of operation 11 4 1 1 Selecting the mode of operation using the operating modes push button 11 4 1 2 Selecting the mode of operation at the mechanical programme switch MPS 12 4 1 3 Selecting the mode of operation usi...

Page 3: ...ditional information carefully X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the given order 1 2 Product liability In compliance with the liability of the manufacturer for his products as defined in the German Product Liability Act compliance with the information contained in this brochure product information and intended use misu...

Page 4: ...nly in the AUTO MATIC and EXIT ONLY modes of operation The door is opened automatically when the button is first pressed and closed again automatically when the button is pressed the second time The function can be activated during commissioning by setting parame ters using the display programme switch ST 220 or GEZEconnects If the activation de vice is connected to the passive leaf control system...

Page 5: ...e electric strike remains switched off until the door has left the closed position Bar message feedback The bar message feedback function is a contact integrated in the door catch that is activated when the door is locked mechanically by the tie bolt of the door lock It sig nals to the control unit that the door is locked mechanically and can therefore not be opened by the door drive In this case ...

Page 6: ...ke sure that the safety stickers are attached visibly to any glass leaves and are in a legible state à à Protect the programme switch against unauthorised access à à Danger of injury by sharp edges on the drive when removing the cover à à Danger of injury by parts hanging down à à This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Page 7: ... installation 1 Door drive unit 2 Link arm or roller guide rail 3 Smoke switch control unit 2 4 Activation device outside KA optional 5 Activation device authorised KB optional 6 Smoke switch 2 7 Activation device inside KI optional 8 Programme switch optional 9 Key switch for enabling the programme switch optional 10 Emergency stop button optional 11 Circuit breaker CLOSE DOOR 2 12 Electric strik...

Page 8: ...ating elements The modes of operation can be set using the following operating elements à à Operating modes push button 21 on the door drive refer to chapter 3 4 1 à à Mechanical programme switch MPS with without integrated key switch optional see chapter 3 4 2 à à Display programme switch optional see chapter 3 4 3 3 4 1 Operating modes push button with operating modes display The operating mode ...

Page 9: ...amme switch MPS ST selection of the modes of operation is disabled if the key provided has been removed Mechanical programme switch MPS ST with integrated key switch 3 4 3 Display program switch optional à à Additionally it can be connected to the internal operating modes push button If a dot appears in the bottom right hand part of the display maintenance is due OFF Display programme switch If a ...

Page 10: ...ng The closing safety sensor has not been activated Door reopens immediately waits the hold open time and then closes at a reduced speed When door closer mode is used with the closing safety sensor deactivated the drive presses against the obstacle with the force set Additional door functions Which switch button What does the switch button do Emergency stop button The door stops immediately in eve...

Page 11: ...ction exit only mode of operation is cancelled and the drive switched back to the automatic mode of operation The occupied displays and lights go out 4 Operation The set parameters of the drive functions may only be modified by a service technician 4 1 Selecting the mode of operation 4 1 1 Selecting the mode of operation using the operating modes push button The operating modes push button can be ...

Page 12: ...ey rotary switch 24 to the required mode of operation The mode of operation is set X X Remove the key The mechanical programme switch MPS ST locked Mechanical programme switch MPS ST with integrated key switch 4 1 3 Selecting the mode of operation using the display programme switch X X Touch the required mode of operation on the display programme switch The mode of operation is set and indicated o...

Page 13: ...X Notify a service technician Fire alarm active only Powerturn F X X Press the Reset switch Drive defective X X Notify a service technician Door does not close After 4 min of permanent activation by the safety sensor the Powerturn Powerturn F automatically closes the door automatically in low energy mode Closing safety sensor SIS soiled X X Clean the closing safety sensor SIS Closing safety sensor...

Page 14: ...n maintenance and repair work must be performed by properly trained personnel authorised by GEZE If a dot appears in the bottom right hand part of the display maintenance is due X X Notify a service technician The maintenance display lights up after the specified calendar period or number of opening cycles depending on what occurs first Powerturn F 1 year or 500 000 cycles GEZE offers maintenance ...

Page 15: ...s connection Fixed connection installation cable or drip loop Primary fuse Secondary fuse 10 A slow blow 5 20 mm Secondary voltage transformer 33 VAC 46 V DC Control voltage for external compo nents 24 VDC 10 Output current control voltage 24 V 1200 mA permanently 1800 mA briefly 2 s duty ratio 30 Fuse protection 24 V 2 5 A reversible Temperature range 15 50 C IP rating IP30 ...

Page 16: ...w geze com cn France GEZE France S A R L Email france fr geze com www geze fr Hungary GEZE Hungary Kft Email office hungary geze com www geze hu Iberia GEZE Iberia S R L Email info geze es www geze es India GEZE India Private Ltd Email office india geze com www geze in Italy GEZE Italia S r l Email italia it geze com www geze it GEZE Engineering Roma S r l Email roma geze biz www geze it Poland GE...