KTR-11 Face/Badge Reader

Installation Manual

Summary of Contents for KTR-11

Page 1: ...KTR 11 Face Badge Reader Installation Manual ...

Page 2: ...IS DOCUMENT FOR THE LATEST DOCUMENTATION CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW GESECURITY COM This publication may contain examples of screen captures and reports used in daily operations Examples may include fictitious names of individuals and companies Any similarity to names and addresses of actual businesses or persons is entirely coincidental Trademarks and patents GE and the ...

Page 3: ...mount installation 4 Frame mount installation 5 Surface mount installation 6 Outdoor installation 7 Wall mount installation 7 Pedestal mount installation 9 Speaker shroud installation 10 Configuration 11 Digital control cable 11 Call return cable 12 Audio cable 13 Door control cables 13 Operation 16 Site programming 18 Contacting technical support 19 Online publication library 19 ...

Page 4: ...KTR 11 Face Badge Reader Installation Manual iv ...

Page 5: ... may be found on our website Refer to Online publication library on page 19 for instructions on accessing our online publication library Note A qualified service person complying with all applicable codes should perform all required hardware installation Conventions used in this document The following conventions are used in this document Safety terms and symbols These terms may appear in this man...

Page 6: ...rator at the control location selects the site 1 two way audio communication and control of the entry point are established and 2 the face of the caller appears on the monitor screen 3 The operator may then send commands to the KTR 11 to select face and face badge camera views raise or lower the face camera s mirror open the door gate or turnstile etc The above sequence describes the face badge re...

Page 7: ...and cable entry positions on the KTR 11 Standard 24 VAC operation The 24 VAC power supply line enters the KTR 11 through one of the two holes located at the bottom left of the unit for attachment after installation to the patch cord provided Connections should be capped with wire nuts see Figure 1 on page 3 Optional 115 V operation KTR 11 E5 The KTR 11 E5 requires a 115 VAC power supply line which...

Page 8: ... HxWxD The bottom of the cutout should be 48 in from the floor Figure 2 2 Bring wires and cables into the KTR 11 through the appropriate openings and insert the KTR 11 unit in the wall cutout 3 Slide the wall brackets into the slots at the top and bottom of the KTR 11 as shown 4 Thread the screws provided through the slots in the brackets but do not tighten 5 Pull each bracket firmly toward the fr...

Page 9: ...e cameras and the mirror assembly if access to any of the holes is obstructed 2 Bring wires and cables into the KTR 11 through the appropriate openings and place the face badge reader in the wall cutout 3 Secure the unit in the framed opening with appropriate fasteners through the four holes 4 Reinstall the cameras and or the mirror assembly if removed Figure 3 Mounting the KTR 11 in a framed cuto...

Page 10: ...he flange is level and mark the location of the four mounting holes on the tabs at the rear of the flange 4 Prepare the mounting holes on the wall for the appropriate mounting bolts 5 Secure the flange to the wall 6 Bring wires and cables into the KTR 11 through the appropriate openings 7 Remount the KTR 11 in the flange using the four bolts removed earlier 8 Reinstall the cameras and or the mirro...

Page 11: ...t flange of the casing and securing with nuts 5 Bring wires and cables into the KTR 11 through the appropriate openings and place the KTR 11 unit in the opening in the trim plate Slide the wall brackets KTR 11 15 into the slots at the top and bottom of the KTR 11 as shown Insert the screws provided through the slots in the brackets but do not tighten Pull each bracket firmly toward the front so th...

Page 12: ...KTR 11 Face Badge Reader Installation Manual 8 Figure 5 Wall mounting outdoors using a KTR 90 weatherproof hood TO FAN TO PHOTOCELL LAMPS FOR REPLACEMENT USE PART GE 97 45 5 TO FLOOR ...

Page 13: ... up through the pedestal and out the two holes in the upper end of the pedestal 4 Place the base of the pedestal on the mounting studs and secure with lock washers and nuts Using a level bring the pedestal into plumb by adjusting the bottom nuts When the pedestal is plumb tighten the top nuts securely Place the base collar over the studs and lock it in place with the screws provided 5 Thread the c...

Page 14: ...Unlock and open the door of the KTR 11 face badge reader 2 Remover the speaker side screw of the existing speaker bracket 3 Install the new speaker shroud over the existing bracket as shown below 4 Install the 6 32 x 1 2 in screw provided and tighten Figure 7 A1 Speaker shroud installation on the KTR 11 Place shroud over speaker bracket Insert new screw Remove screw ...

Page 15: ...304RA and connects to the KTR 11 through terminals 1 and 2 of the lower barrier strip on the KTR 11 PC card Figure 8 and Figure 9 on page 12 Note The RS 422 cable has polarity At any location you must ensure that Digital A corresponds with the Digital A of any other controllers receivers and switchers connected to the system Figure 8 System cable connections KTD 304A colors refer to wiring interna...

Page 16: ...olarity The common line must connect to all common terminals throughout the system zoom in auto out zoom far focus near focus open iris close iris set 7 4 1 0 8 5 2 clear 9 6 3 over badge face mon seq alarm door 1 talk 1st stop aux 1 vol vol access control video switcher control site select pan tilt alarm control door 2 close open focus auto A B A B A B B A S B A RS422 CONTROL SIGNAL OUT AUDIO SIG...

Page 17: ...d contains two relays that provide dry contacts 1 A at 24 V for door control See Figure 10 and Figure 11 on page 14 for connection details Figure 10 Door control and audio connections KTD 304A DOOR 1 STATUS COMMON DOOR 2 STATUS FROM DOOR 2 SENSOR SENSOR ELECTRIC STRIKE DOOR 1 CALL DOOR 2 CALL FROM DOOR 2 CALL BUTTON STATUS CALL PUSH BUTTON DOOR 1 AUDIO A DOOR 1 AUDIO B SPEAKER HORN DOOR 2 AUDIO B ...

Page 18: ...OOR 2 CALL FROM DOOR 2 CALL BUTTON STATUS CALL PUSH BUTTON 9 8 7 6 5 4 3 2 1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 DOOR 1 AUDIO A DOOR 1 AUDIO B SPEAKER HORN DOOR 2 AUDIO B DOOR 2 AUDIO A TO FROM DOOR 2 AUDIO KTR 11 PC CARD LOCATED IN THE KTR 11 FACE BADGE READER 15 14 13 12 11 OPEN CLOSE COMMON TO GATE CABLE CONNECTIONS FOR GATE OPERATION 24V AC OR DC IN TO DOOR 2 DRY CONTACT OUTPUTS ...

Page 19: ...15 Figure 12 Video connections BADGE VIDEO FACE CAM GEN LOCK FACE VIDEO 24VAC TO FACE CAM 24VAC TO BADGE CAM FACE CAMERA BADGE CAMERA DOOR 1 CAMERA CAMERA OVERVIEW CAMERA DOOR 2 VIDEO OUTPUT ...

Page 20: ... to operate the KTR 11 Call Technical Support for details face badge over door1 door2 aux1 aux2 Video switcher control keys Site select keys Special application key Access control keys and special application PTZ control keys Special function keys typically multiplexer applications zoom in auto out zoom far focus near focus open iris close iris set 7 4 1 0 8 5 2 clear 9 6 3 over badge face mon seq...

Page 21: ...ted receiver site s pan tilt unit in the autopan mode camera pans left and right automatically Also used in combination with set to initiate the preset tour mode autofocus Engages autofocus mode on the CyberDome Video switcher control keys mon Used in combination with the number keys 0 9 to select an active monitor seq Used to start selected sequence tour on active monitor alarm Toggles the active...

Page 22: ... Toggles between a full screen view and a 2x view of the selected video if available on the specific multiplexer live Used to view the live video inputs in any of the display modes also used during setup of motion detection areas vcr Selects VCR output for monitoring during taping or VCR input for viewing during playback Also used in setup of motion detection areas full Used by some multiplexer ty...

Page 23: ...ite To access our publication library go to our website at the following location http www gesecurity com In the Tools area at the top click the Publication Library link After you register and log on you may search through our online library for the documentation you need 1 Table 2 Sales and support contact information Sales Technical support Phone Toll free 888 GESECURity 888 437 3287 in the US i...

Page 24: ...KTR 11 Face Badge Reader Installation Manual 20 ...

Reviews: