background image

Warranty, Service & Repair

WARRANTY

Flowline warrants to the original purchaser of its products that such

products will be free from defects in material and workmanship under

normal use and service for a period which is equal to the shorter of

one year from the date of purchase of such products or two years from

the date of manufacture of such products.

This warranty covers only those components of the products which

are non-moving and not subject to normal wear. Moreover, products

which are modified or altered, and electrical cables which are cut to

length during installation are not covered by this warranty.

Flowline’s  obligation  under  this  warranty  is  solely  and  exclusively

limited to the repair or replacement, at Flowline’s option, of the prod-

ucts (or components thereof) which Flowline’s examination proves to

its  satisfaction  to  be  defective.  FLOWLINE  SHALL HAVE  NO

OBLIGATION FOR CONSEQUENTIAL DAMAGES TO PERSON-

AL OR REAL PROPERTY, OR FOR INJURY TO ANY PERSON.

This warranty does not apply to products which have been subject to

electrical or chemical damage due to improper use, accident, negli-

gence, abuse or misuse. Abuse shall be assumed when indicated by

electrical damage to relays, reed switches or other components. The

warranty does not apply to products which are damaged during ship-

ment back to Flowline’s factory or designated service center or are

returned without the original casing on the products. Moreover, this

warranty becomes immediately null and void if anyone other than ser-

vice personnel authorized by Flowline attempts to repair the defective

products.

Products which are thought to be defective must be shipped prepaid

and insured to Flowline’s factory or a designated service center (the

identity and address of which will be provided upon request) within

30 days of the discovery of the defect. Such defective products must

be accompanied by proof of the date of purchase.

Flowline further reserves the right to unilaterally wave this warranty

and to dispose of any product returned to Flowline where:

a. There  is  evidence  of  a  potentially  hazardous  material  present

with product.

b. The product has remained unclaimed at Flowline for longer than

30 days after dutifully requesting disposition of the product.

THERE  ARE  NO  WARRANTIES  WHICH  EXTEND  BEYOND

THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This

warranty and the obligations and liabilities of Flowline under it are

exclusive and instead of, and the original purchaser hereby waives, all

other  remedies,  warranties,  guarantees  or  liabilities,  express  or

implied. EXCLUDED FROM THIS WARRANTY IS THE IMPLIED

WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTIC-

ULAR PURPOSE OR USE AND THE IMPLIED WARRANTY OF

MERCHANT ABILITY OF THE PRODUCTS.

This warranty may not be extended, altered or varied except by a writ-

ten instrument signed by a duly-authorized officer of Flowline, Inc.

To register your product with the manufacturer, go to the Flowline

website for on-line registration.  The website address is as follows:

www.flowline.com

On-line Warranty Registration can be found under Contact Us in

the Navigation Bar along the side of the home page. 
If for some reason your product must be returned for factory ser-

vice, contact Flowline Inc. at (562)598-3015 to receive a Material

Return  Authorization  number  (MRA),  providing  the  following

information:

1. Part Number, Serial Number

2. Name and telephone number of someone who can answer

technical questions related to the product and its application.

3. Return Shipping Address

4. Brief Description of the Symptom

5. Brief Description of the Application

Once you have received a Material Return Authorization number,

ship the product prepaid in its original packing to:

Flowline Factory Service

MRA _____

10500 Humbolt Street

Los Alamitos, CA 90720

To avoid delays in processing your repair, write the MRA on the

shipping label.  Please include the information about the malfunc-

tion with your product.  This information enables our service tech-

nicians to process your repair order as quickly as possible.

®

Version 0.1A

© 2005 FLOWLINE Inc.

All rights reserved.

Manual # LM900005

05/05

Switch Pak™

w/ Compact 

Relay Controller

A _ 1 3 Series

Owner’s Manual

Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088   Phone: 888 SPECTECH

E-mail: [email protected]              www.spectechind.com

Summary of Contents for Switch Pak A*13 series

Page 1: ...here is evidence of a potentially hazardous material present with product b The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY This warranty and the obligations and liabilities of Flowline under it are exclusive and instead of and the or...

Page 2: ...0 psi 10 bar AV13 25 psi 1 7 bar Wetted material 42__ PP 52__ PVDF Kynar Process mount _2_3 2 NPT _2_7 1 1 2 G Enclosure rating NEMA 4X IP65 Installed height _21_ 6 5 16 5 cm _22_ 4 9 12 4 cm Encl material _21_ PP UL94VO and polycarbonate _22_ PP UL94VO Conduit entrance Single 1 2 NPT Classification General purpose CE compliance EN 50082 2 immunity EN 55011 emission EN 61010 1 safety Sensor Techno...

Page 3: ...evel Switch P N LU10 1305 LU10 1325 LU10 2305 LU10 2325 LV10 1301 LV10 1351 LV10 5301 LV10 5351 or LZ12 1405 A Specify Ultrasonic AU13 4223 1 x LU10 1305 1 x LM45 1001 1 x LC10 1001 AU13 4227 1 x LU10 1325 1 x LM45 1061 1 x LC10 1051 AU13 5223 1 x LU10 2305 1 x LM45 5001 1 x LC10 1001 AU13 5227 1 x LU10 2325 1 x LM45 5061 1 x LC10 1051 Buoyancy AV13 4223 1 x LV10 1301 1 x LM45 1001 1 x LC10 1001 A...

Page 4: ...al wiring of any liquid level control system should be performed in accordance with all applic able national state and local codes Take care not to cut or break the outer insulation jacket of wiring that may be immersed while routing cables in the Switch Pak system Such breaks of the liq uid seal of the sensor system may lead to component failure Flammable Explosive and Hazardous Applications The ...

Page 5: ...overed in the Installation section of the LC10 11 Series Manual Polarity neu tral and hot does not matter 4 Relay terminals NC C NO Connect the device you wish to control pump alarm etc to these terminals supply to the COM terminal and the device to the NO or NC terminal as required The switched device should be a noninductive load of not more than 10 amps for reactive loads the current must be de...

Page 6: ... is completely disconnected 2 Sensor Removal Make sure that the tank is in a state where it is safe to remove the sensors Carefully remove the Switch Pak from the installation 3 Cleaning the Sensor Use a soft bristle brush and mild deter gent carefully wash the Switch Pak Do not use harsh abra sives such as steel wool or sandpaper which might damage the surface sensor Do not use incompatible solve...

Reviews: