background image

Electronic Super Ducha 

Instructions for installation and use

MINIMUM PRESSURE TO ALLOW 

SUPER DUCHA 4 WORKING: 

13 kPa/ 1,8 psi (1,3 meters of water 

column height)

MAXIMUM PRESSURE TO ALLOW 

SUPER DUCHA 4 WORKING:

400 kPa (40 meters of water column height)

Minimum  pressure  to  activate  the 
appliance:  8  kPa/  1psi 
(0,8  meters  of  water  column  height)

Storage tank

Verify the height of the water column 
from the appliance to the storage tank. 
If it's greater than 5 meters keep the 
pressure reducer, if it's smaller take the 
pressure reducer off.

Minimum 

wire 

section (mm)

Circuit 

breaker 

(Amperes)

Maximum distance 

from the circuit 

breaker (m)*

4,0

10,0

50

29

Equipment 

content

Volts 

(V)

Nominal 

power 

(Watts)

127

5400

Check the product 

specification 

on the package

32

32

220

6800

Apply sealing tape on the inlet nipple (11).

Screw the ELECTRONIC SUPER DUCHA 

using only your hands.

After preparing for the hydraulic installation according to Options 1 or 2, 
having proceed to the hydraulic installation as follow:

1 - 

Pipe inlet niple (1/2 Gas thread).

2 - 

Support for the pipe.

3

 - Pipe (30 cm).

4

 - Fixing screw for the Support.

5 -

 Electronic temperature control:

0

 0 (off) variation until maximum power.

6

 - Flexible wire (electrical circuit).

7

 - Electrical conductors finishing (12 cm).

8 -

 Wires (electrical circuit).

9 -

 Yellow-green wire (grounding).

10 -

 Electrical conductors finishing (30 cm).

11 -

 Water inlet niple (1/2 Gas thread).

12 -

 

*

Water economizer “Pressure Reducer”

(verify the recommendations below)

13 -

 Heating chamber.

14 -

 Spray plate.

15 -

 Mark for spray plate remotion.

16 -

 Outlet pipe for hand shower.

17 -

 Cover of water outlet pipe.

18 -

 Hand shower and hose.

19

 - Hand shower holder.

(   )

 Keep

 the pressure reducer on whenever  the water pressure is 

higher than 5 meters (50 kPa).

(   ) 

Take 

the pressure reducer out whenever the water 

pressure goes from 1,3 to 5 meters (13 to 50 kPa/ 1,8 psi).

The Electronic Super Ducha must be preferably installed at a height of 2.10 meters from the 
floor to the water pipe outlet.  In this way the water will not get cool during the flow.

The Electronic Super Ducha must be preferably installed at a height of 2.10 meters from the 
floor to the water pipe outlet.  In this way the water will not get cool during the flow.

Check if the exclusive independent electric circuit that will provide energy to the 
ELECTRONIC SUPER DUCHA has the necessary minimum section, as shown 
in the table below.

(*) For larger distances, contact a technician. 

 

The Picture is not on a scale basis

When happens variation in the tension (voltage) it will also happen 
variation in the temperature of the water.

Installation

This product should be installed by a technician.

Sealing tape

Screwdriver 

Fixed 
wrench

Connector

- To connect the appliance wires to the electrical circuit, use a FAME connector or a brand of your choice.

- Never use plugs or outlets.

- On phase +neutral circuits, the phase wire should be connected to the phase and the neutral to the neutral. On phase+ 
phase there is not this distinction.

- Use a bipolar circuit breaker for bipolar circuits of 220 volts (F+F).

- The water resistivety at the temperature of 15° C must not be less than 1300 Ω cm. Level of protection IP-24.

- The electrical installation of FAME's Electronic Super Ducha must be done in an exclusive and independent circuit.

Before starting the hidraulic installation

Hydraulic Installation

Preparing for the Hydraulic installation - Option B

OPTION B:

Preparing for the Hydraulic installation - Option A

OPTION A

Needed material:
- Connector
- Sealing tape
- Screwdriver
- Fixed wrench

These materials do not come with the product. 

SHOWER

- Before carrying out any work ensure that the electricity supply is turned off. The tension (voltage) 
of the circuit is the same of the appliance and if the wire section and the circuit breaker are in 
accordance with the tag with the product features next to the bar code.

OFF

Technical features

- Clean up the water outlet pipe (C) to remove any residue.

- Ensure that the electrical circuit is turned off.

- Open the water-tap and let water flow to eliminate the residues. 

- Check if the hydraulic connection diameter is ½ “ or use an adapter.

Apply  sealing  tape  on  the  inlet 
niple (1), screw it together with 
the  Support  using 

only  with 

your hands, until the flange is 
close to the wall (Picture 1)

Apply  sealing  tape  in 
the inlet niple (1), screw 
the  pipe 

using  only 

your  hands,  ensure 
that  the  flange  is 
close  to  the  wall 
(picture 1).

Pass the Support through 
the  pipe  to  the  point 
shown  in  the  Picture  in 
order  to  facilitate  the 
access  to  the  wires 
during  the  electrical 
instalation.

Before proceeding this 
step,  ensure  that  the 
Support  is  aligned  to 
the  wall  in  a  vertical 
position (Picture 2).

Before  proceeding  this  step, 
ensure  that  the  Support  is 
aligned to the wall in a vertical 
position (Picture 2).

With  a  screwdriver  loose  the 
screw of the Support (4), move 
the screw on the pipe to the point 
shown  in  the  picture  this  will 
enable  the  access  to  the  wires 
during the electrical installation. 

Insert the Electronic Selector in the 
Support's hole following the guides 
to  ensure  that  the  Selector  is 
installed in the correct position.

To  Put  back  the  Selector  button  on  the 
Selector,  align  it  to  zero  (0)  and  gently 
press it. 

Water 
inlet niple

Pipe + Support

Pipe + Support

Water 
inlet niple

Pipe

3

1

1

2

3

FLOOR

Before installing, check which option (A or B) is more suitable for 
the place where your ELECTRONIC SUPER DUCHA will be installed.

Before installing, check which option (A or B) is more suitable for the place 
where your ELECTRONIC SUPER DUCHA will be installed:

If the distance between the hidraulic connection and 
the roof is 22cm or above, 

there is enough space to 

screw the setting pipe + support in the  hidraulic connection. 
It is not necessary to separate the setting pipe + support.

If the distance between the hidraulic connection and the roof 
is 

 22cm,

 there isn't enough space to screw the setting 

below

pipe + support in the  hidraulic connection. It is necessary to 
separate the setting pipe + support.

A = Electric Connection
B = Hidraulic Connection

A = Electric Connection
B = Hidraulic Connection

ROOF

13cm

16cm

2,10 m

A

B

Electronic selector

Axis of selector

Washer

Hex nut

Support

Selector button

Electronic Selector Guide

Support

Guide

FLOOR

ROOF

13cm

22cm

2,10 m

A

B

Open the water tap and let the water flow for some seconds. This operations aims to fill the heating 
chamber to avoid damage to resistance and checking if there is leakage.

If there is a leakage, fix it before proceeding with the installation.

1A

1B

2B

4B

3B

2A

Flange

Flange

Water 

inlet niple

Water 
inlet niple

Height:

Minimum: 1,3 meters (m.c.a.)
Maximum: 40 meters (m.c.a.)

Picture 1

Picture 2

Picture 1

Electronic selector

Washer

Hex nut

Selector button

Button on 
position (0)

Marking (0)
Finish

Selector button

Limit Point

Checking if there is leakage

Support

Support

Shower

Pipe

Screw

Electronic

Control

Support

Screw

Axis of selector

Selector

vertical 

alignment

Picture 2

Limit Point

vertical 

alignment

1

1

2

2

2

11

Support

Pipe

2

3

2

3

4

4

2

3

8

9

5

4

6

7

12

13

14

15

16

17

18

19

11

10

C

ø

1/2”

Product Description

To separate the pipe from the Support 
proceed as follow: 
With a Phillips scredriver unscrew the 
Fixing screw (4) from the Support (2) 
and then from the pipe (3).
Separate  the  electronic  temperature 
control from the Support:
1  -  Put  the  temperature  selector  in 
position (0) and pull it to remove from 
the selector axis.
2 - With a Fixed wrench (10 mm) loose 
the hex nut.
3 - Remove the washer.

Obs: keep these components in a 
safe place not to loose them.

Observe the correct sequency of the 
assembly:
1 - Insert the Electronic Selector;
2 - Insert the washer on axis;
3 - Tight the hex nut on the Electronic 
Selector  using  a  Fixed  wrench 
(10 mm);
4 - Put back  the Selector button on it. 

Reviews: