background image

USER MANUAL

Thermal Imager IR
Thermometer

MODEL IRC130

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 

Summary of Contents for IRC130

Page 1: ...USER MANUAL Thermal Imager IR Thermometer MODEL IRC130 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ... Menu 9 5 3 SETTINGS Sub Menu 11 6 Field Firmware Updates 16 6 1 System Firmware Update 16 7 Maintenance 17 7 1 Cleaning 17 7 2 Battery Considerations and Service 17 7 3 Disposal of Electronic Waste 17 7 4 Reset the IRC130 17 8 Specifications 18 8 1 Imaging and Optical Specifications 18 8 2 Detector Specifications 18 8 3 Image Presentation Specifications 18 8 4 Measurement Specifications 19 8 5 Me...

Page 3: ...tery Specifications 21 8 13 Environmental Specifications 21 8 14 Physical Specifications 22 8 15 Included Equipment 22 9 Warranty and Customer Support 23 9 1 Two Year Warranty 23 9 2 Repair and Calibration Services 23 9 3 Customer Support 23 NAS100031 r AD 63425 63425 en US iii ...

Page 4: ......

Page 5: ...dds key details from the visible spectrum to the IR image for improved diagnostics Easy to read 320 x 240 2 4 TFTcolor LCD display Wide temperature range 4 1202 20 650 High temperature switch for measurements 752 400 Intuitive programming menu system in over 21 languages 3 presets and 1 custom emissivity setting LED Flashlight Laser pointer and cross hair display for easy targeting 4 GB internal i...

Page 6: ...d PC interface CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure CAUTION Use extreme caution when the Laser pointer is on CAUTION Do not point the Laser beam toward anyone s eye or allow the beam to strike the eye from a reflective surface CAUTION Do not use the Laser near explosive gases or in other pot...

Page 7: ...on buttons Power long press Menu short press button 5 Lanyard post 6 Accessory mount 7 High temperature lever switch 8 80 x 60 pixel Lepton IR camera 9 Laser pointer with circular target spot assist 10 USB C jack compartment 11 Spot thermal sensor 12 Flashlight LED 13 2M pixel visible spectrum camera 14 Image capture trigger also used to exit the menu system NAS100031 r AD 63425 63425 en US 3 ...

Page 8: ...d in the menus Press to scroll downward in the menus Press and hold to use the Laser pointer TRIGGER Pull trigger to capture camera image Pull trigger to exit the menu system 3 3 Display Description Figure 3 2 IRC130 Displays 1 Menu area 2 Date and time 3 Battery status percentage 4 Battery status indicator 5 USB connection active 6 Camera image area NAS100031 r AD 63425 63425 en US 4 ...

Page 9: ...Description 3 7 Center spot cross hairs 8 Laser Pointer active 9 Center spot temperature measurement NAS100031 r AD 63425 63425 en US 5 ...

Page 10: ... the selected APO time Use the menu system under Device Settings To set the APO timer See Sec tion 5 Programming Menu System for more information 4 2 IR Camera and Thermometer Figure 4 1 Combined Thermal and Visible Image MSX 1 Long press the power button to switch the unit ON 2 If not already selected choose the Thermal plus Visible Image mode in the menu system under Image Adjustments Image Mode...

Page 11: ... function is enabled 6 The temperature reading on the display represents the measurement of the targeted spot See Figure 4 1 7 The distance to spot ratio is 30 1 and the minimum target distance is 10 2 in 26 cm 8 To measure higher than 752 400 use the High Temperature Switch see Section 4 3 below 9 If a measurement is out of range the display will show OL 10 To adjust the Emissivity use the menu s...

Page 12: ...display confirmation will briefly appear showing the image filename 3 To view images on the IRC130 display access the Gallery mode in the main menu In the Gallery scroll through the stored images with the ar rows and open an image with the MENU button 4 To delete images select the DELETE or DELETE ALL FILES command to erase the selected image or all of the stored images Select CANCEL to exit the m...

Page 13: ...to confirm settings Use the trigger to exit the menu system 5 2 Main Menu GALLERY Press MENU to access the stored images Use the arrow but tons to scroll through the stored images and use the MENU button to open an image Press MENU at an opened image to see the CANCEL DELETE DELETE ALL FILES menu LIGHT Short press MENU to switch the Flashlight ON or OFF IMAGE ADJUSTMENTS Press MENU to access IMAGE...

Page 14: ...he visible image line up accurately as follows While viewing the THERMAL PLUS VISIBLE IMAGE screen in the menu press MENU to access the MSX adjustment screen and then use the arrow buttons to adjust the alignment Press MENU to confirm Note that you can also adjust the alignment directly in the normal operating mode using the arrow buttons while viewing a Thermal Plus Visible image NAS100031 r AD 6...

Page 15: ... and use the arrow buttons to se lect a color palette Iron Rainbow White hot Black hot Arctic or Lava Press MENU to confirm selection SETTINGS Press MENU to access the Settings sub menu see below 5 3 SETTINGS Sub Menu MEASUREMENT NAS100031 r AD 63425 63425 en US 11 ...

Page 16: ...rgeting 2 Emissivity Press MENU to open the Emissivity adjustment utility Use the arrows to scroll through the presets 0 95 0 80 and 0 60 and use the MENU button to select a preset Choose the Custom Value utility last se lection on the list to select a specific emissivity value At the Custom Val ue setting press MENU and then use the arrows to select the emissivity value press MENU to confirm DEVI...

Page 17: ...er pointer Use the Laser pointer for accurate targeting of measurement spots 2 Screen brightness Use the arrows to select the desired display intensity LOW MEDIUM or HIGH 3 Auto Power OFF APO Use the arrows to scroll and MENU to select the desired APO time 5 15 30 minutes Set to Never to disable APO GENERAL SETTINGS NAS100031 r AD 63425 63425 en US 13 ...

Page 18: ...ws and the MENU button to select C or F 2 Time Date Use the arrows to scroll and the MENU button to set the Time Date Time Format and Date Format 3 Language Use the arrows to scroll and the MENU button to select a language NAS100031 r AD 63425 63425 en US 14 ...

Page 19: ...erial Number Software Level Revision Battery status and remaining Internal Storage Capacity GENERAL SYSTEM INFO Press MENU to view compliance information FACTORY RESET Follow the prompts to reset the User Settings back to Factory Default status NAS100031 r AD 63425 63425 en US 15 ...

Page 20: ... the update file is located https support flir com The IRC130 to be updated The update file Refer to the steps in the next section 6 1 System Firmware Update 1 Visit https support flir com to obtain a firmware update file 2 Select the Downloads tab and then select Software and Firmware 3 Search for IRC130 4 Select and download the firmware update file to the PC 5 With the IRC130 ON connect it to t...

Page 21: ...h a PC USB port is not recommended If the unit is not going to be used for an extended period 3 months it should be charged to at least 70 stored at room temperature and re charged every 6 months Failure to do so may result in a battery that cannot be recharged and that therefore will require service 7 3 Disposal of Electronic Waste As with most electronic products this equipment must be disposed ...

Page 22: ... temperature lever must be engaged Focus Fixed Image frequency 8 7 Hz 8 2 Detector Specifications Focal plane array Spectral response range Uncooled microbolometer 7 5 14 μm Detector pitch 12 μm 8 3 Image Presentation Specifications Display resolution 320 x 240 pixels Screen size 2 4 in portrait Viewing angle 80 Color depth 24 bit Aspect ratio 4 3 Display type TFT technology Image adjustment Autom...

Page 23: ...Temperature resolution 0 2 0 1 Reading repeatability 1 of reading or 2 1 whichever is greater Response time 150 ms IR thermometer measurement Continuous scanning Minimum measurement distance 0 85 ft 0 26 m 8 5 Measurement Analysis Specifications Spot meter Center spot cross hairs Programmable ON OFF Color display palettes Iron Rainbow White hot Black hot Arctic and Lava 8 6 Configuration Specifica...

Page 24: ...MC 4G Image storage capacity 50000 images Image file format JPEG with spot temperature metadata tag 8 8 Digital Camera Resolution 2M pixels Focus Fixed Field of View FOV 71 x 56 adapts to IR lens 8 9 Flashlight Specifications Flashlight type Bright LED LED CCT 6500 K LED CRI 70 Beam angle 20 Rated power 0 5 W Light output 100 Lumens 8 10 Laser Pointer Specifications Laser type DOE Diffractive Opti...

Page 25: ... hours with Laser ON medium bright ness setting Battery charge life 30 days minimum Charging system Battery is charged inside the IRC130 Charging time 4 hours to 90 and 6 hours to 100 Power management APO adjustable 5 15 30 minutes Can be disabled 8 13 Environmental Specifications Altitude 6562 ft 2000 m Pollution degree 2 Operating temperature 14 113 10 45 Storage temperature 22 131 30 55 Humidit...

Page 26: ...ctive 2011 65 EC WEEE Directive 2012 19 EC JIS C 6802 2011 laser directive IEC 60825 1 class I laser directive FDA laser directive Humidity requirements IEC 60068 2 30 for operation and storage 8 14 Physical Specifications Weight 13 9 oz 0 39 kg Size L x W x H 8 3 x 2 5 x 3 2 in 210 x 64 x 81 mm Accessory mount UNC 20 8 15 Included Equipment Standard equipment IRC130 USB C cable printed Quick Star...

Page 27: ...d cables 9 2 Repair and Calibration Services FLIR Systems Inc offers calibration and repair services for the Extech brand products we sell We offer NIST traceable calibration for most of our products Contact us for information on calibration and repair availability Annual calibra tions should be performed to verify meter performance and accuracy Product specifications are subject to change without...

Reviews: