background image

EWT-955WH

Installation Manual

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes

Yes
Yes
Yes
Yes

No

Power Type

Battery Power*

Hardwire (Common Wire)

Hardwire (Common Wire) with 

Battery Backup

Table of Contents

Wireless Type Selection

Installation Tips

Thermostat Quick Reference

Private Label Badge

Wireless Communication Tips

Reestablishing Communication

Wiring

Technician Setup Menu

Setting the Humidity

Programming

Specifications

 

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en español de este 

manual se puede descargar en 

la pagina web de la compañia.

Rev. 1841

     U.S. Registered Trademark. Patents pending

Copyright      2018 All Rights Reserved.

3-8

13

2

Yes
Yes

14-18

Wireless Type Selection

Installation Tips

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind the thermostat

•  In areas that do not require conditioning

•  Where there are dead spots or drafts (in corners or behind doors)

•  Where there might be concealed chimneys or pipes

Wall Locations

Pick an installation location that is easy for the user to access.  The temperature 

of the location should be representative of the building.

Installation Tip

Do not install thermostat in these locations:

Installation Tips

19-28

29

11

9-10

The thermostat and base module contain selectable wireless 

communication options. Each component has a jumper switch label 

FSK and ASK. Default setting: FSK.

• All components must be set to the same position for wireless 

  communication.

• Both modes utilize a 916 MHz frequency.

• FSK: frequency-shift keying, is the recommended mode.

• ASK: amplitude-shift keying, should be selected when using 

  components that can not communicate with FSK.

The images below illustrate the location of jumper switches for each 

item that has one. Note only the thermostat and Base Module are 

included in this package.

Back

FSK/ASK Switch

Back

FSK/ASK Switch

T955WH

RZ250W

The table below lists the mode options for T955WH 

wireless thermostat and its accessories.

*Compatible with Z955W - Wireless Zoning Controller

Component

Mode Options

T955WH Thermostat
T955WH Thermostat Base Module
RZ251W - Indoor Remote*
RZ250W - Outdoor Remote*
R251W - Indoor Remote
R250W - Outdoor Remote
W150W - Wireless Repeater

FSK or ASK
FSK or ASK
FSK or ASK
FSK or ASK

ASK
ASK
ASK

Vertical Mount

Horizontal Mount

For horizontal mount put one screw on 
the left and one screw on the right.

All of our products are mercury free. However, if the product you are 

replacing contains mercury, dispose of it properly.  Your local waste 

management authority can give you instructions on recycling and 

proper disposal.

Mercury Notice

Failure to disconnect the power before beginning to install this product 

can cause electrical shock or equipment damage.

Installation Tip: Electrical Hazard

For vertical mount put one screw on 
the top and one screw on the bottom.

Thermostat Subbase Installation

12

30-38

39

Humidity
Dual Fuel

Yes
Yes

* If you are using remote 

sensors the thermostat 

must be hardwired.

C

R

FSK / ASK

RESET

+

 

C

 

R

FSK/ASK

+

B1

 ASK/FS

K

RZ251W

 A

SK

/F

SK

RE

SET

IM

S

 A

SK

 F

SK

 A

SK

 FS

K

JP1

JP

3

ASK/FSK

BASE MODULE

 ASK/FSK

c
o

Summary of Contents for EWT-955WH

Page 1: ...lation Tips 19 28 29 11 9 10 The thermostat and base module contain selectable wireless communication options Each component has a jumper switch label FSK and ASK Default setting FSK All components must be set to the same position for wireless communication Both modes utilize a 916 MHz frequency FSK frequency shift keying is the recommended mode ASK amplitude shift keying should be selected when u...

Page 2: ...ical Mount Horizontal Mount For horizontal mount put one screw on the left and one screw on the right For vertical mount put one screw on the top and one screw on the bottom To connect the base module to the master thermostat refer to the directions on page 13 of this manual Note Wire the base module s subbase the same way you would wire a hardwired thermostat subase Wiring Note The base module mu...

Page 3: ...ation Tips Do not install the base module in locations That are behind a chimney Where temperature could exceed 150 F Where rain or snow or extreme hot or cold is possible Note This base module is NOT weatherproof Wireless Communication Tips Follow these steps for a simple wireless communication setup Locate all components in area near equipment Wire base module with 8ft pigtail and temporarily mo...

Page 4: ...terminal block can keep the thermostat from fitting on the subbase correctly or cause system operation issues Installation Tip Max Torque 6in lbs Wiring If you are replacing a thermostat make note of the terminal connections on the thermostat that is being replaced In some cases the wiring connections will not be color coded For example the green wire may not be connected to the G terminal Loosen ...

Page 5: ... compressor run time to OFF 3 4 or 5 minutes If 3 4 or 5 is selected the compressor will run for at least the selected time before turning off Minimum Compressor OnTime OFF You can adjust the room temperature display to read up to 4 above or below the factory calibrated reading Adjustment Options Default LCDWillShow OFF 0 OFF This thermostat has a technician setup menu for easy installer configura...

Page 6: ...tup Steps Adjustment Options Default LCDWillShow You can configure the thermostat to operate a 3 stage heat pump system 2H 2C 2 heat 2 cool 3H 2C 3 heat 2 cool This feature is shown only if the HEAT PUMP technician setup step is ON Stages of Heat Use the or key to change between 2 or 3 stages of heat 2 heat will useY1 as first stage andW2 as auxiliary 3 heat will useY1 as the first stage Y2 as the...

Page 7: ...SOR FINDING SENSOR Disable the sensor on the master At least one indoor remote sensor must be connected to disable the local sensor LocalTemp Sensor YES enables local sensor NO disables local sensor YES YES LOCAL TEMP SENSOR Turns on the heat for 10 minutes each hour if unable to communi cate with the master thermostat if there has been a call for heat in the last 24 hours Freeze Protection YES en...

Page 8: ...hen completed Humidity Key Target humidity setpoint keys Note The target humidity setpoint is not programmable Unlike temperature humidity does not change quickly and should not be programmed Note Humidity is only energized during heat Dehumidity is only energized during cool Heat and cool each have their own target setpoints Ambient Humidity Display Ambient humidity will flash opposite the day an...

Page 9: ...u are now programming the OCCUPIED time period for that day 4 Use the or key to make your time selection for the OCCUPIED time period Note If you want the fan to run continu ously during this time period select ON with the FAN key 5 Then use the or key to make your setpoint selection for that day s OCCUPIED period 6 Press NEXT 7 Repeat steps 4 through 6 for that day s UNOCCUPIED time period Monday...

Page 10: ...o customize your 7 day Program schedule follow these steps Monday Repeat steps 4 through 6 for the remaining days of the week A Note About Auto Changeover In Auto you have the ability to switch between Auto Heat or Auto Cool by pressing the system key This can be done once the current mode has reached its setpoint For example if in Auto Heat the heat setpoint must be satisfied before the thermosta...