Features: 

◩ 

3G (Tri-band HSDPA/UMTS) Connectivity 

◩ 

Standard RS232 9DF serial port 

◩ 

6v to 35v power input on RJ12 connector 

◩ 

4(or 7) x digital, analogue or pulse I/O’s on RJ45 connector 

◩ 

SMA M antenna connector

 

◩ 

Sleep Mode for reduced power consumption 

Issue 27012009 

Cinterion 

HC25(HC28) Inside 

ETM9900(J) 
Quick Start Guide 

HSDPA/UMTS/GSM/GPRS Terminal 

Summary of Contents for ETM9900(J)

Page 1: ...l port 6v to 35v power input on RJ12 connector 4 or 7 x digital analogue or pulse I O s on RJ45 connector SMA M antenna connector Sleep Mode for reduced power consumption Issue 27012009 Cinterion HC25...

Page 2: ...ard 6 Indicator Lights 7 Installation 8 Configuration Tool 8 Introduction 8 Using the Right Version of the Configuration Tool 8 Using the Configuration Tool 8 Modem Initialisation Settings Main Init T...

Page 3: ...Page 3 of 16 ETM9900 J Quick Start Guide Issue 27012009...

Page 4: ...mment Module Installed ETM9900 First Release HC25 Release 1 0 1 2 1 78 or 2 05 ETM9900 1 Future Release HC25 Release 2 05 7 x I O s versus 4 x I O s for ETM9900 ETM9900J First Release Japan only unit...

Page 5: ...tput LL0V 0 1mA HL3V 0 1mA 3 Configurable as Digital Input LL 0 5V HL 2 5V Max Input 50VDC Digital Output LL0V 0 1mA HL3V 0 1mA Analogue Input 0 2 5VDC 4 Configurable as Digital Input LL 0 5V HL 2 5V...

Page 6: ...n 5 GND 6 DSR Out 7 RTS In 8 CTS Out 9 RING Out Antenna The ETM9900 J Terminal has a standard SMA Jack Female antenna Plug on the end of an approximately 90mm cable 3V SIM Card The SIM card connector...

Page 7: ...Hz and appr 50 duty cycle when the ME is in power saving state and not registered to any network When the ME is in power saving state and not registered the flashing frequency may be less than 0 25Hz...

Page 8: ...on configuring the unit for the intended application SMS alarm IP connectivity etc Configuration Tool Introduction The HC25 HC28 engine used in the ETM9900 J does not support storing of an active pro...

Page 9: ...ck on the Read EE Tab Blue Arrow to read current configuration If first attempt to read is unsuccessful repeat 8 Use the Main Init Settings Alarm Message I O or other Tabs to enter required settings 9...

Page 10: ...tions using a Circuit Switch Data Call Control Via ET Commands As default the ETM9900 J is set to ET Command Mode ET Commands are specific to ETM terminals and allow for control configuration and info...

Page 11: ...nications between modem and external device have stalled Show I O settings ETRIS Show status value of each I O 1 DI 1 2 DI 1 3 DI 1 4 DI 1 5 DI 1 6 DI 1 7 DI 1 I O 1 Digital Input 1 I O 2 Digital Inpu...

Page 12: ...level alarm Flow switch alarm to warn if flow is lost in a pumping system Alarm relay from a machine such as a refrigeration unit Example Assume an alarm message is required to be sent to two phone nu...

Page 13: ...ed to open circuit Note 1 Delay before alarm is activated is recommended to reduce the incidence of multiple SMS being sent in the event of chattering bouncing contacts 2 Alarm restore delay stops add...

Page 14: ...PC Server room Monitoring tank or stream levels using a level transmitter Example Monitor a server room SMS based on temperature rise and or fault alarm from A C unit Wiring Diagram Configuration Tool...

Page 15: ...the message A C Unit Fault will be sent to each phone number when I O1 changes from open to closed circuit 3 Set I O3 as Analogue in this case 4mA represents 40o C which corresponds to 500mV and 20mA...

Page 16: ...ETM Matteknik AB Subject to change without notice...