Emerson Wireless 1420 Gateway

Summary of Contents for Smart Wireless Gateway 1420

Page 1: ...Reference Manual 00809 0200 4420 Rev HE September 2020 Emerson Wireless 1420 Gateway ...

Page 2: ...ent and a fault condition or installation error occurs high voltage may be present on transmitter leads and terminals Use extreme caution when making contact with the leads and terminals This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions This device may not cause harmful interference This device must accept any interference received including interf...

Page 3: ...tion 36 4 4 Security Setup Utility 36 4 5 AMS Wireless Configurator 38 4 6 Licensing and credits 40 Chapter 5 Operation and Maintenance 43 5 1 Overview 43 5 2 Network architecture 43 5 3 Internal firewall 46 5 4 Modbus 47 5 5 EtherNet IP 53 Chapter 6 Troubleshooting 57 6 1 Service support 57 6 2 Troubleshooting Tables 57 6 3 Return of materials 61 Chapter 7 Glossary 63 Appendix A Specifications an...

Page 4: ... B 6 USA 75 B 7 Canada 76 B 8 Europe 76 B 9 International 77 B 10 Brazil 77 B 11 China 78 B 12 Japan 78 B 13 EAC Belarus Kazakhstan Russia 78 B 14 Combination 78 Appendix C DeltaV Ready 79 C 1 Overview 79 C 2 Latency considerations in control logic design and operation 79 C 3 Requirements 79 C 4 Mounting and connecting 79 C 5 Setup 80 Appendix D Redundancy 85 D 1 Overview 85 D 2 Requirements 85 D ...

Page 5: ...The box containing the Gateway contains several items essential to the complete installation and operation of the Gateway Emerson Wireless 1420 Gateway Quick Start Guide Software pack 2 disk set Mounting hardware Conduit plugs four Conduit adapters optional If an optional remote antenna has been ordered it will be in a separate box containing Remote mount antenna Mounting hardware Lightning arrest...

Page 6: ...Maintenance describes how to connect the Gateway to a host system and integrate data gathered from the field device network It covers network architectures security and data mapping Troubleshooting provides troubleshooting tips as well as information to contact technical support over the phone or through email Glossary defines terms used throughout this manual or that appear in the web interface o...

Page 7: ...way PC laptop 24 VDC nominal power supply Note If the Gateway was ordered with the DeltaV Ready option it has been configured to operate on a DeltaV control network and the Initial Configuration Section does not need to be completed Only setting the password is required 2 2 System requirements The following requirements apply to the PC laptop used to configure the Gateway Additional requirements m...

Page 8: ... will need to be disabled through the PC laptop s default Internet browser Procedure 1 Find and open the default internet browser typically Microsoft Internet Explorer 2 From the Tools menu select Internet Options 3 From the Connections tab select LAN Settings 4 Under Proxy Server verify the boxes for Automatically Detect Settings and Use a proxy server for your LAN are unchecked 5 Select OK to cl...

Page 9: ...s the standard terminal block diagram Once the Gateway and PC laptop are connected wire a 24 VDC nominal power supply with a capacity of at least 250 mA to the Gateway power input terminals Determining Gateway compatibility with Power over Ethernet PoE Figure 2 1 Legacy Gateway Terminal Block A B S S S S S A B C D E F G G G G A Case B Ethernet 2 with power covered C Ethernet 2 secondary D Ethernet...

Page 10: ... only transmitted from one device to another when the proper impedance match is made This prevents damage to non PoE devices on the network In the Gateway power is transmitted in passive mode over two unused differential pairs of the Ethernet cable To use this feature the Gateway must be connected over the Ethernet to a matching IEEE 802 3a device Failure to do this will cause no power to be sent ...

Page 11: ...y and sends power down the Ethernet port selected to another device EN Enabled this enables the PSE operation DIS Disabled this disables the PSE operation Note Only one port and one mode of operation PD or PSE can be selected at a time any other combination of jumpers is invalid Note IEEE 802 3af 2003 PoE standard provides up to 15 4 W of DC power minimum 44 V DC and 350 mA to each device Only 12 ...

Page 12: ...n the left hand side with four main areas Diagnostics view status of communications client server parameters and more Monitor screens created by the user to view data from field devices Explorer basic view of values from field devices Setup configure the Gateway for operations security and host system integration Security passwords There are four role based user accounts for the Gateway with varyi...

Page 13: ...options be changed to the local IT best practices or the Normal setting after initial login Strong or custom settings are available for more robust passwords For more information on this screen and others see the Emerson Wireless Gateway User Interface Terminology Guide Time settings The Gateway is the timekeeper for the WirelessHART network so it is imperative that the Gateway s time is accurate ...

Page 14: ... log into the Gateway Contact the network administrator for information on the proper TCP IP network settings to apply Prior to the gateway being installed and connected to a live control network it should be configured with an IP address as well as other TCP IP network settings Request the following configuration items from the network administrator Specify an IP address or use a DHCP server Host...

Page 15: ...ss recommended 3 Enter the following Hostname Domain Name IP Address Netmask Gateway 4 Select Save Changes 5 When prompted select Restart apps 6 Select Yes to confirm restart 7 Close the web browser Note Once the IP Address of the Gateway has been changed communications to the web interface will be lost Restart the web browser then log back into the Gateway using the new IP address and other TCP I...

Page 16: ...ngs Gateway Backup And Restore 2 Select Save Backup 3 The Gateway collects the configuration date and when the file download pop up appears select Save 4 Enter a save location and file name 5 Select Save 6 Select Return to form Note System backup contains user passwords and keys used for encrypting communication Store downloaded system backups in a secure location These files themselves are also e...

Page 17: ...device network 3 1 2 Physical description For dimensional drawing information refer to Product Certifications The cast aluminum housing encloses the electronics circuitry of the Gateway The front of the enclosure has an upper cover and a junction box cover The upper cover provides access to the electronics and radio The junction box cover provides access to the terminal block To open either cover ...

Page 18: ...ts supplied with Gateway 2 in mounting pipe in socket head wrench Mount the Gateway using the following procedure Procedure 1 Insert one u bolt around the pipe through the top mounting holes of the Gateway enclosure and through the washer plate 2 Use a in socket head wrench to fasten the nuts to the u bolt 3 Repeat for the second u bolt and the lower mounting holes Installation Reference Manual Se...

Page 19: ...aced 3 06 in 77 mm apart horizontally and 11 15 in 283 mm apart vertically in the support bracket corresponding with the holes on the Gateway enclosure 2 Using a 1 2 in socket head wrench attach the Gateway to the support bracket with four 15 16 in bolts 3 3 Remote antenna optional The remote antenna options provide flexibility for mounting the Gateway based on wireless connectivity lightning prot...

Page 20: ...ble connections for the lightning arrestor and antenna Find a location where the remote antenna has optimal wireless performance Ideally this will be 15 25 ft 4 6 to 7 6 m above the ground or 6 ft 2 m above obstructions or major infrastructure To install the remote antenna use one of the following procedures 3 3 1 Installation of WL2 WN2 option outdoor applications Procedure 1 Mount the antenna on...

Page 21: ...tning arrestor near the building egress 3 Install the grounding lug lock washer and nut on top of lightning arrestor 4 Connect the antenna to the lightning arrestor using the supplied coaxial cable ensuring the drip loop is not closer than 1 ft 0 3 m from the lightning arrestor 5 Connect the lightning arrestor to the Gateway using the supplied coaxial cable 6 Use the coaxial sealant to seal each c...

Page 22: ... B Remote antenna C Cable D Drip loop E Lightning arrestor F Gateway G Ground H Earth CAUTION Weather proofing is required The remote mount antenna kit includes coaxial sealant for the cable connections for the lightning arrestor antenna and Gateway The coaxial sealant must be applied to guarantee performance of the wireless field network See Figure 3 5 for details on how to apply weather proofing...

Page 23: ...n of the enclosure The terminal block label is located on the inside of the lower cover See Figure 3 6 for the standard terminal block label The junction box portion of the enclosure has four conduit entries for power and communications wiring Do not run communication wiring in conduit or open trays with power wiring or near heavy electrical equipment Install the included conduit plugs in any unus...

Page 24: ... access to the Gateway Figure 3 6 Terminal Block A B S S S S S A B C D E F G G G G A Case B Ethernet 2 with power covered C Ethernet 2 secondary D Ethernet 1 primary E 24 VDC nominal power input F Serial Modbus G Not used Figure 3 7 PoE Compatible Gateway Terminal Block A B S A B C D E A Case B Ethernet 2 secondary C Ethernet 1 primary D 24 VDC nominal power input E Serial Modbus Ethernet connecti...

Page 25: ...the RS 485 data bus The total bus length should not exceed 4000 ft 1220 m Connect the Tx positive transmit wire to terminal A and the Rx negative receive wire to terminal B The wiring shield should be trimmed close and insulated from touching the Gateway enclosure or other terminations Only terminated at one end typically at the power supply end If the existing data bus uses a 4 wire Full Duplex c...

Page 26: ...h 1 is for the Tx A line and Switch 3 is for the Rx B line These 470 Ω resistors are used to prevent noise from being interpreted as valid communications during periods when no actual communications are occurring Only one set of pull up and pull down resistors should be active on the RS 485 data bus at time Switch 2 is connected to a 120 Ω terminating resistor This resistor is used to dampen signa...

Page 27: ... there be a loss of power Note When using PoE PD a power supply is not required 3 4 6 Power over Ethernet PoE The new Gateway hardware supports IEEE 802 3af and IEEE 802 3at PoE With the growth of Ethernet many have wanted to save time and cost on wiring by sending power down to an Ethernet device over the same Ethernet cable used to haul data This is possible because there are four extra wires in...

Page 28: ...ected to a Wi Fi back haul unit such as a Cisco or ProSoft unit For example a Cisco unit could power the Gateway or in another case the Gateway could power the ProSoft unit as in a PFN with the addition of an external power supply Selecting devices to work with a PoE Gateway The connecting device to the Gateway whether it is a PSE or a PD must be labeled as compliant with IEEE 802 3af or IEEE 802 ...

Page 29: ...ng characteristic based on the IEEE 802 3 standard receive power via the Ethernet cable To determine whether a PD is connected the input parameters are checked by the PSE This method is called Resistive Power Discovery During the discovery process resistance capacitance and current are checked If the PSE detects a PD it starts classification i e determination of the power requirement of the connec...

Page 30: ... codes as PoE is approved for that application For example typically N5 or N6 approvals take the least time These approvals codes when approved for PoE would automatically ship with the new hardware Approval codes like N3 or N4 which typically take a longer time would ship with PoE at a later date Contact your Emerson Sales Representative to find out if a particular code has been approved for PoE ...

Page 31: ... will work with a local power supply connected to the power input terminals of the Gateway and as a PD with power coming over the Ethernet at the same time If both sources are present the Gateway selects the local power supply first If the local power fails the Gateway automatically switches to Ethernet power When the local power is restored the Gateway automatically returns to local power How do ...

Page 32: ...oducts year after year The following is a list of some improvements with the new hardware Ethernet connectors in line with conduit holes A fast disconnect circuit protects from someone inadvertently wiring Gateway to high voltage or AC Mains circuit resets when improper power is removed More area freed up for installer wiring in lower section Total number of circuit boards wires and connectors is ...

Page 33: ...PSE on port 1 PoE PSE on port 2 ETH1 Ethernet port 1 selected for PD or PSE ETH2 Ethernet port 2 selected for PD or PSE PD Gateway gets its power off the Ethernet port selected PSE Gateway gets its power from a local power supply and sends power down the Ethernet port selected to another device EN Enabled this enables the PSE operation DIS Disabled this disables the PSE operation Note Only one por...

Page 34: ...Installation Reference Manual September 2020 00809 0200 4420 34 Emerson com Rosemount ...

Page 35: ...provisioning Disk 2 Network Configuration This application configures AMS Wireless Configurator to interface to a Wireless Network or a HART Modem Disk 2 Additional system components may be installed depending on the current configuration of the system 4 2 System requirements Table 4 2 PC Hardware Minimum requirements Recommended requirements Intel Core 2 Duo 2 0 GHz Intel Core 2 Quad 2 0 GHz or g...

Page 36: ...ws programs including any running in the background such as virus scan software 2 Insert Disk 2 into the CD DVD drive of the PC 3 Select Install from the menu when the AMS Wireless Configurator setup begins 4 Follow the prompts 5 Allow AMS Wireless Configurator to reboot PC 6 Do not remove the disk from the CD DVD drive 7 Installation will resume automatically after login 8 Follow the prompts Note...

Page 37: ...rough various proxies within the Security Setup Utility These proxies can function as a data server for other applications on the control network The Security Setup Utility can support multiple Gateways at once and each proxy can support multiple client application connects Figure 4 1 shows a typical system architecture using the Security Setup Utility Figure 4 1 Typical Host System Architecture U...

Page 38: ...the admin password for the target Gateway 8 Select OK 9 Repeat Step 2 Step 8 to added additional proxies 10 Select FILE EXIT to close the Security Setup Utility During this process the Gateway will exchange security certificates digital signatures with the proxy Figure 4 2 Security Setup Utility 4 5 AMS Wireless Configurator AMS Wireless Configurator helps deploy and configure wireless field devic...

Page 39: ...cation To run this application select START ALL PROGRAMS DEVICE MANAGER NETWORK CONFIGURATION Note Do not have the Security Setup Utility running at the same time as the Network Configuration application or a configuration error might occur Use the following procedure to configure a wireless network for AMS Wireless Configurator Procedure 1 Open the Network Configuration application 2 Select Add 3...

Page 40: ...elect the HART master type default is AMS Wireless Configurator will be Primary HART master and select Next 7 Select the COM port for the HART modem and select Next 8 Check the box to Check to support Multi Drop devices 9 Check the box to Include WirelessHART Adapter 10 Select Finish to close the configuration window 11 Select Close to exit the Network Configuration application 4 6 Licensing and c...

Page 41: ... This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit www openssl org Reference Manual Commissioning 00809 0200 4420 September 2020 Emerson com Rosemount 41 ...

Page 42: ...Commissioning Reference Manual September 2020 00809 0200 4420 42 Emerson com Rosemount ...

Page 43: ...ing the network architecture and what protocols can be used for integration Ethernet is the primary physical connection type and RS 485 is available as an optional connection type The following network architecture diagrams will help when integrating data from the Gateway into the host system 5 2 1 Ethernet An Ethernet connection supports Modbus TCP OPC AMS Wireless Configurator Ethernet IP and HA...

Page 44: ...ber optic connection supports Modbus TCP OPC AMSWireless Configurator and HART TCP protocols Using this connection type the Gateway is wired to a fiber optic switch see Figure 5 2 Note A fiber optic connection requires a third party copper Ethernet to fiber optic Ethernet converter Operation and Maintenance Reference Manual September 2020 00809 0200 4420 44 Emerson com Rosemount ...

Page 45: ...fiber converter H Gateway RS 485 serial An RS 485 connection supports Modbus RTU protocol Using this connection type the Gateway is wired to an RS 485 bus which typically leads to a serial I O card or Modbus I O card see Figure 5 3 Up to 31 Gateways can be connected to a single I O card in this manner Reference Manual Operation and Maintenance 00809 0200 4420 September 2020 Emerson com Rosemount 4...

Page 46: ...orts an internal firewall that inspects both incoming and outgoing data packets TCP ports for communication protocols are user configurable including user specified port numbers and the ability to disable ports The Gateway s internal firewall settings can be found by navigating to System Settings Protocols Protocols and Ports Operation and Maintenance Reference Manual September 2020 00809 0200 442...

Page 47: ... client host system 5 4 1 Communication settings It is import that the Modbus communication settings in the Gateway match the setting in the Modbus master or client Refer to host system documentation for more information on how to configure these settings The Modbus communication settings can be found by navigating to System Settings Protocols Modbus Reference Manual Operation and Maintenance 0080...

Page 48: ...TU Stop Bits This setting determines the number 1 or 2 of stop bits to use when ending a message This setting is only required for Modbus RTU Response delay time ms This setting determines how long ms the Gateway waits before responding to a Modbus request This setting is only required for Modbus RTU Unmapped register read response This is the value returned by the Gateway if the Modbus master req...

Page 49: ...nes what value is reported if the wireless field device reports a failure or stops communicating to the Gateway This setting is used for rounded or scaled integers The choice is a user specified value between 32768 and 65535 Scaled floating point maximum integer value This determines the maximum integer value for the purpose scaling integers 999 65534 Use global scale gain and offset This setting ...

Page 50: ...es is selected on the Modbus Communications page Register This is the Modbus register number used for this data value Modbus registers hold two bytes 16 bits of information therefore 32 bit floats and integers require two Modbus registers Each data point needs a unique Modbus register number unless they are assigned different addresses Register numbers 0 19999 are reserved for Boolean bit coil bin...

Page 51: ...THY parameters are a true false indication of the health of a particular variable dynamic variable PV SV etc These parameters incorporate critical diagnostics from the wireless field device as well as communication status Note The _HEALTHY parameters are a great indication of the health and communications status of the data values State state value The value of a data point which drives a Modbus o...

Page 52: ...M_DIAG ADDITIONAL_STATUS_0 49015 8 bit unsigned int SYSTEM_DIAG ADDITIONAL_STATUS_1 49016 8 bit unsigned int SYSTEM_DIAG ADDITIONAL_STATUS_2 49017 8 bit unsigned int SYSTEM_DIAG ADDITIONAL_STATUS_3 49018 8 bit unsigned int SYSTEM_DIAG ADDITIONAL_STATUS_4 49019 8 bit unsigned int SYSTEM_DIAG ADDITIONAL_STATUS_5 49020 8 bit unsigned int SYSTEM_DIAG ADDITIONAL_STATUS_6 49021 8 bit unsigned int SYSTEM...

Page 53: ...hernet IP master or client Refer to host system documentation for more information on how to configure these settings or to the Emerson Wireless Gateway Integration Reference Manual for Ethernet IP The Ethernet IP communication settings can be found by navigating to System Settings Protocols EtherNet IP Network architectures should reflect that of a DeltaV system see unique_72 unique_72_Connect_42...

Page 54: ...ll be reported through the Ethernet IP member Value reported for error floating point Chooses what value is reported if the value s associated status indicates a critical failure Only used if the Gateway is using float representation NaN Not a number is reported if the value s associated status indicates a critical failure Inf Positive infinity is reported if the value s associated status indicate...

Page 55: ...ing data points from wireless field devices to Ethernet IP registers These registers can then be read by a Ethernet IP master or client Ethernet IP register mapping can be found by navigating to System Settings Protocols EtherNet IP EtherNet IP Member Map Figure 5 8 Ethernet IP Register Map Page Table 5 4 Summary of Terms Used for the Ethernet IP Mapping Page Terms Description Input Instance Ether...

Page 56: ...ll table entries Select None De selects all table entries Select Errors Selects all table entries that have an error message Submit Accepts all changes highlighted in yellow Add a new data point To add a new data point to the Ethernet IP register map Procedure 1 Select New entry 2 Complete all of the table entries for the new data point note that the entry columns may vary based on the Ethernet IP...

Page 57: ...he United States contact your local Emerson representative 6 2 Troubleshooting Tables Table 6 1 Troubleshooting Initial Connection Issue Troubleshooting steps Web browser returns page not found 1 Connect the Gateway and PC laptop 2 Verify the Gateway is properly powered 24 VDC nominal and 250 mA Open the upper cover and verify if any indicator lights are on 3 Verify which Ethernet port is being us...

Page 58: ...e using the Network Configuration application See Section 4 Commissioning 3 Verify if the wireless network interface is configured for Secure Gateway Communications 4 Verify secure unsecure AMS Wireless Configurator protocol settings in the Gateway Log on to the Gateway and navigate to SETUP SECURITY PROTOCOLS 5 Restart AMS Wireless Configurator data server Right click on AMS Wireless Configurator...

Page 59: ...ing Modbus RTU 1 Verify the use of RS 485 2 Verify wiring connections See Section 3 Installation 3 Verify if termination is required 4 Verify that Modbus serial communications setting in the Gateway match the Modbus Host settings Log on to the Gateway and navigate to SETUP MODBUS COMMUNICATIONS 5 Verify the Modbus address for the Gateway 6 Verify Modbus register mapping in the Gateway Log on to th...

Page 60: ...pplication 2 Configure an OPC proxy for the Gateway See Section 4 Commissioning Gateway OPC server does not show any Gateways 1 Configure an OPC proxy for the Gateway See Section 4 Commissioning Gateway OPC server does not show any data tags 1 Configure the Gateway OPC Browse Tree Log on to the Gateway and navigate to SETUP OPC OPC BROWSE TREE 2 Verify the connection status for the OPC proxy in th...

Page 61: ... a Return Material Authorization RMA number The center will also ask for the process material to which the product was last exposed WARNING Individuals who handle products exposed to a hazardous substance can avoid injury if they are informed of and understand the hazard If the product being returned was exposed to a hazardous substance as defined by OSHA a copy of the required Material Safety Dat...

Page 62: ...Troubleshooting Reference Manual September 2020 00809 0200 4420 62 Emerson com Rosemount ...

Page 63: ...figure the TCP IP parameters of a device Domain A unique designator on the internet comprised of symbols separated by dots such as this domain com Gateway Refers to the Smart Wireless Gateway HART Tag The device s electronic tag that the Gateway uses for all host integration mapping Refers to the HART long tag 32 characters used for HART 6 or 7 devices or the HART message 32 characters only used f...

Page 64: ...ss field device Calculated as the ratio of the number of received messages over the number of expected messages Takes into account all paths RSSI Received signal strength indication dBm for the wireless field device Secondary Interface Ethernet 2 port used for backup connection or a maintenance port for local access Security Setup Utility A software application that enables secure communications b...

Page 65: ... being powered Input voltage Normal Operation no PSE or IEEE 802 3af 10 5 30 VDC PoE PSE Operation IEEE 802 3at 17 5 30 VDC A 1 3 Current draw Operating current draw is based on 3 6 Watts power consumption A Current mA B Voltage VDC Momentary startup current draw up to twice operating current draw A 1 4 Radio frequency power output from antenna Maximum of 10 mW 10 dBm EIRP Reference Manual Specifi...

Page 66: ...imum EMC deviation limit or reset however device will self recover and return to normal operation within specified start up time A 1 7 Antenna options Integrated Omni directional Antenna Optional remote mount Omni directional Antenna A 2 Physical specifications A 2 1 Weight 10 lb 4 54 kg A 2 2 Material of construction Housing Low copper aluminum NEMA 4X Paint Polyurethane Cover gasket Silicone Rub...

Page 67: ...ng distance is approximately 4000 ft 1 524 m A 3 2 Ethernet 10 100base TX Ethernet communication port Protocols Modbus TCP OPC EtherNet IP HART IP https for Web Interface Wiring Cat5E shielded cable Wiring distance 328 ft 100 m A 3 3 Modbus Supports Modbus RTU and Modbus TCP with 32 bit floating point values integers and scaled integers Modbus Registers are user specified Reference Manual Specific...

Page 68: ...2 wireless devices at one seconds A 4 3 Supported device update rates 1 2 4 8 16 32 seconds or 1 60 minutes A 4 4 Network size latency 100 Devices less than 10 seconds 50 Devices less than five seconds A 4 5 Data reliability 99 percent A 5 System security specifications A 5 1 Ethernet security specifications Secure Sockets Layer SSL enabled default TCP IP communications A 5 2 Gateway access Role b...

Page 69: ...g Enable Disable and user specified port numbers Inspects both incoming and outgoing packets A 5 5 Third party certification Wurldtech Achilles Level 1 certified for network resiliency National Institute of Standards and Technology NIST Advanced Encryption Standard AES Algorithm conforming to Federal Information Processing Standard Publication 197 FIPS 197 Reference Manual Specifications and Refer...

Page 70: ... 283 12 03 306 6 72 171 4 78 121 3 08 78 1 59 40 3 99 101 B C A Lower cover remove for electrical connections B Ground lug C 1 2 in NPT conduit connection four places Dimensions are in inches millimeters Specifications and Reference Data Reference Manual September 2020 00809 0200 4420 70 Emerson com Rosemount ...

Page 71: ...i antenna kit includes sealant tape for remote antenna connection as well as mounting brackets for the antenna lightning arrestor and the Smart Wireless Gateway Lightning protection is included on all the options WL3 and WL4 provide lightning protection along with the ability to have the Gateway mounted indoors the antenna mounted outdoors and the lightning arrestor mounted at the building egress ...

Page 72: ...e Rate Operating Frequency and Protocol A3 User configurable update rate 2 4 GHz DSSS WirelessHART Serial Communication N None A 5 Modbus RTU via RS485 Ethernet Communication Data Protocols 2 Webserver Modbus TCP IP AMS Wireless Configurator ready HART IP 4 Webserver Modbus TCP IP AMS Wireless Configurator ready HART IP OPC 5 6 DeltaV ready 6 6 Ovation ready 8 Webserver EtherNet IP AMS Wireless Co...

Page 73: ...ernet port with RJ45 connector 2 Additional ports disabled 3 Dual active 10 100 baseT Ethernet ports with RJ45 connectors 4 Multiple active ports have separate IP addresses firewall isolation and no packet forwarding 5 Convertible to RS232 via adaptor not included with Gateway 6 Includes Webserver Modbus TCP AMS Ready HART IP and OPC 7 Options may or may not come with POE See terminal block config...

Page 74: ... replacement 1 Remote antenna 50 ft 15 2 m cable and Lightning arrestor 01420 1615 030 2 Spare kit WL3 replacement 1 Remote antenna 20 30 ft 6 1 9 1 m cables and Lightning arrestor 01420 1615 030 3 Spare kit WL4 replacement 1 Remote antenna 10 40 ft 3 0 12 2 m cables and Lightning arrestor 01420 1615 030 4 Spare kit WN2 replacement 1 High Gain Remote antenna 25 ft 7 6 m cable and Lightning arresto...

Page 75: ...This device must accept any interference received including interference that may cause undesired operation This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons B 4 Ordinary location certification As standard the transmitter has been examined and tested to determine that the design meets the basic electrical mechanical and fire protection requirem...

Page 76: ...en connected per Rosemount drawing 01420 1011 Type 4X Special Conditions for Safe Use X 1 Explosion Hazard Do not disconnect equipment when a flammable or combustible atmosphere is present B 8 Europe N1 ATEX Type n Certificate Baseefa07ATEX0056X Standards EN 60079 0 2012 EN 60079 15 2010 Markings II 3 G Ex nA IIC T4 Gc T4 40 C Ta 65 C VMAX 28Vdc Special Conditions for Safe Use X 1 The equipment is...

Page 77: ...The surface resistivity of the antenna is greater than 1 GΩ To avoid electrostatic charge build up it must not be rubbed with a dry cloth or cleaned with solvents NF IECEx Dust Certificate IECEx BAS 07 0013X Standards IEC 60079 0 2011 IEC 60079 31 2008 Markings Ex tc IIIC T135 C Dc 40 C Ta 65 C Special Conditions for Safe Use X 1 The surface resistivity of the antenna is greater than 1 GΩ To avoid...

Page 78: ... n Certificate T64855 Markings Ex nA nL IIC T4 B 13 EAC Belarus Kazakhstan Russia NM Technical Regulation Customs Union EAC Type n Certificate RU C US ГБ05 B 00578 Markings 2Ex nA IIC T4 X T4 40 C Ta 65 C IP66 Special Conditions for Safe Use X 1 See certificate for special conditions B 14 Combination KD Combination of N1 N5 and N6 Product Certifications Reference Manual September 2020 00809 0200 4...

Page 79: ...latency is two seconds the amount of time that could pass between when an event occurred in the field and before it is available to the DeltaV I O bus is between zero and 15 8 2 5 seconds The update period of the DeltaV control module should be added to that total to determine the range of latencies before an event in the field can be acted upon by the control system Operators should be made aware...

Page 80: ...mary control network C Secondary control network D Controller and I O E Gateway C 5 Setup Out of the box the Gateway is pre configured for use on the DeltaV control network In the DeltaV Explore application the Gateway will automatically appear in the Decommissioned Nodes folder C 5 1 Setup a wireless network To setup a wireless network will require three steps Procedure 1 Commission the Gateway 2...

Page 81: ...PHYSICAL NETWORK DECOMMISSIONED NODES 3 Right click on the Smart Wireless Gateway and select Commission 4 Enter a name for the Gateway and select OK 5 Select YES when prompted to Auto Sense Wireless Gateway At this time the Reconcile I O window will appear The purpose of this screen is to assign WirelessHART devices to DeltaV I O channel This allows the wireless device to be referenced in other De...

Page 82: ...ntinue C 5 4 Assign the gateway to a DeltaV controller Next the Gateway will need to be assigned to a DeltaV Controller and download all Assign and download the Gateway using the following procedure Procedure 1 Right click on the Gateway and select Assign 2 Use the browse window and select the desired controller 3 Select OK to close the assignment window 4 Right click on the Gateway and select Dow...

Page 83: ...DeltaV channels through the reconcile process right click on Gateway and select configure IO Note Logging in to the Gateway is not possible using the default TCP IP network setting If the Gateway is decommissioned use an IP address 10 5 255 254 If the Gateway is commissioned right click on the Gateway in DeltaV Explore and select Wireless Gateway Web Interface Reference Manual DeltaV Ready 00809 0...

Page 84: ...DeltaV Ready Reference Manual September 2020 00809 0200 4420 84 Emerson com Rosemount ...

Page 85: ...recommended RD option for Gateway Redundancy Static IP Address Must have matching output protocols e g Modbus or OPC on each Gateway Host system Ethernet connection for Modbus TCP or OPC DA communications Serial RS 485 connection for Modbus RTU communications D 3 Setup redundant gateways When configuring redundant Gateways it is only necessary to configure one system The other Gateway will be conf...

Page 86: ... messages and host system integration to help identify each Gateway It is recommended that these names be marked on each physical Gateway in addition to the configuration settings Selecting left or right for Gateway A is for visualization purposes only It has no effect on performance or functionality Figure D 1 System Settings Gateway Redundancy Redundancy Reference Manual September 2020 00809 020...

Page 87: ...ry Ethernet port on Gateway A 2 Log in using the admin user account 3 Navigate to Diagnostics Advanced Redundancy Status 4 Connect the secondary Ethernet port on Gateway A to the secondary Ethernet port on Gateway B see Figure D 3 Figure D 3 5 A dialog will appear on the page select Form redundant pair 6 Wait for the Pairing to redundant peer status to turn green 7 Select Return to page Reference ...

Page 88: ...ion to the standard practices the following considerations should be taken when installing redundant Gateways D 4 1 Mounting The redundant Gateways should be mounted in a location that allows convenient access to the process control network as well and provides good coverage for the wireless field network The redundant Gateway antennas should be mounted at the same height and be spaced between 3 9...

Page 89: ...e same process control network Consult a control system administrator for more details about available redundant network switches D 4 3 Simplex RS 485 A simplex RS 485 host connection supports Modbus RTU protocol When using this architecture connect the secondary Ethernet port on Gateway A directly to the secondary Ethernet port on Gateway B Then wire the RS 485 ports for both Gateways in parallel...

Page 90: ...ture the primary Ethernet ports can be connected to an asset management network to provide connectivity to AMS Device Manager or AMS Wireless Configurator D 4 4 Dual RS 485 A Dual RS 485 host connection support Modbus RTU protocol When using this architecture connect the secondary Ethernet port on Gateway A directly to the secondary Redundancy Reference Manual September 2020 00809 0200 4420 90 Eme...

Page 91: ...ller and I O D Dual serial card E RS 485 bus F Secondary Ethernet Note By default only the active Gateway in a redundant system will respond to Modbus polling requests If simultaneous polling is desired login to the Gateway web interface navigate to Setup Modbus Communications and set Respond when running as redundant standby to Yes Only use this setting in a dual RS 485 architecture Reference Man...

Page 92: ...y Status Diagnostics Advanced Redundancy Status These diagnostics can also be mapped to Modbus registers or OPC tags The following table covers what diagnostics are included on the Redundancy Status page as well as how they can be mapped as parameters in Modbus or OPC Table D 1 Redundancy Diagnostics Parameter Description Data type REDUNDANT_HEALTH Y Overall redundancy status indicating the system...

Page 93: ...st IP address Boolean REDUNDANT_B_ETH0 Electrical connection status of the primary Ethernet port for Gateway A 8 bit unsigned int D 5 1 Configure network connectivity In addition to the redundancy diagnostics an additional check may be configured to test network connectivity to a host system or other application The redundant system will use this check to determine the best connectivity option and...

Page 94: ...ay is being reintroduced i e it was a part of the original redundant system it will automatically rejoin the redundant system If the Gateway is new or has been set to default configuration it will need to be paired to the current active Gateway Navigate to System Settings Gateway Redundancy and follow the recommended actions on that page or follow the procedure above to pair Gateways and form a re...

Page 95: ...Reference Manual 00809 0200 4420 September 2020 Emerson com Rosemount 95 ...

Page 96: ... 41 0 41 768 6111 41 0 41 768 6300 RFQ RMD RCC Emerson com Asia Pacific Regional Office Emerson Automation Solutions 1 Pandan Crescent Singapore 128461 65 6777 8211 65 6777 0947 Enquiries AP Emerson com Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P O Box 17033 Jebel Ali Free Zone South 2 Dubai United Arab Emirates 971 4 8118100 971 4 8865465 RFQ RMTMEA Emerson c...