background image

Contents

Safety Notice  ...............................................................    02
Unit Illustr ation
Impor tant Testing Guidelines 
Quick  Star t    .................................................................   10

Blood Pr essur e Infor mation
Blood Pr essur e Q

A

Maintenance
Specifications

   .........................................................    06 

  .....................................    09

Unit Oper ation   ...........................................................    12

   ........................................   26

   ...................................................   30

   ...............................................................   32

   .............................................................    36

Wa r r anty   ....................................................................     40

   Batter y Installation  ..................................................   12
   System Settings  ........................................................    13  
   Applying The Wr ist Monitor   ....................................   15
   Testing   .....................................................................   17
   Power Off   .................................................................   21
   Memor y Check   ........................................................    22
   Memor y Deletion   .....................................................  23
   Low Batter y Indicator   .............................................    24
   Tr oubleshooting   ......................................................    25

Safety Notice

Safety Notice

Safety Notice

Owner ' s Manual

Wrist-type Fully Automatic 

Blood Pressur e Monitor 

Model

  BP 2116

1

3

2

4

Wrist Type

Thank you for purchasing the B P 2116 Blood Pressure Monitor. 

The unit has been constructed using reliable circuitry and 

durable materials. Used properly, this unit will provide years

of satisfactory use.

7.To avoid any possibility of accidental strangulation, keep this 

    unit away from children and do not drape tubing around your 

    neck.

8.Ensure that children do not use the instrument unsupervised;

    some parts are small enough to be swallowed.

9.Some may get a skin irritation from the cuff taking frequent  

   readings over the course of the day, but this irritation typically 

   goes away on its own after the monitor is removed.

The device is intended for use by individuals 12 years and older

to measure the systolic and diastolic  blood  pressure  and pulse  

rate. All values can be read out in one LCD DISPLAY. 

Blood pressure measurement determined with this device are 

equivalent to those obtained by a trained observer using the 

cuff/ stethoscope auscultation method, within the limits 

prescribed by the American National Standard (ANSI/AAMI 

Sp10) for electronic sphygmomanometers.
Pr ecautions to Ensur e Safe, Reliable Oper ation

1. Do not drop the unit. Protect it from sudden jars or shocks.

2. Do not insert foreign objects into any openings.

3. Do not attempt to disassemble the unit.

4. Do not crush the pressure cuff.

o

5. If the unit has been stored at temperatures below 0  C, leave it 

    in a warm place for about 15 minutes before using it. 

    Otherwise, the cuff may not inflate properly.

6. Do not store the unit in direct sunlight, high humidity or dust.

Document No.

Version: REV03.02.22.16

Important Instructions Before Use

1. Do not confuse self-monitoring with self-diagnosis. 

    Blood pressure measurements should only be interpreted by a 

    health professional who is familiar with your medical history.

2. Contact your physician if test results regularly indicate 

    abnormal readings.

3. If you are taking medication, consult with your physician to 

    determine the most appropriate time to measure your blood 

    pressure. NEVER change a prescribed medication without first 

    consulting with your physician.

4. Individuals with serious circulation problems may experience 

    discomfort. Consult your physician prior to use.

5. For persons with irregular or unstable circulation resulting 

    from diabetes, liver disease, arteriosclerosis or other medical 

    conditions, there may be variations in blood pressure values 

    measured at the wrist versus at the upper arm. Monitoring the 

    trends in your blood pressure taken at either the arm or the wrist 

    is nevertheless useful and important.

7. People suffering from arrhythmias such as atrial or ventricular 
    premature beats or atrial fibrillation only use this blood pressure 
    monitor in consultation with your doctor. In certain cases 
    oscillometric measurement method can produce incorrect 
    readings.

8. Too frequent measurements can cause injury to the patient due to 

    blood flow interference.

9. The cuff should not be applied over a wound as this can cause  

    further injury.

10.DO NOT attach the cuff to a limb being used for IV infusions or
      any other intravascular access, therapy or an arterio-venous  (A-
      V) shunt. The cuff inflation can temporarily block blood flow, 
      potentially causing harm to the patient.
11.The cuff should not be placed on the arm on the side of a 
      mastectomy. In the case of a double mastectomy use the side of 
      the least dominant arm.
12. Pressurization of the cuff can temporarily cause loss of function 

Contact Information

The lay operator or lay responsible or ganization should contact

 the manufacturer or the representative of manufacturer.

-for assistance,if needed,in setting up,using or maintaining 

the product,or

-to report unexpected operation or events.   

Drive Medical
99 Seaview Blvd
Port Washington, NY 11050
Toll-Free 877-224-0946
www.drivemedical.com

6. People suffering from vascular constriction, liver disorders or 

    diabetes, people with cardiac pacemakers or a weak pulse, and 

    women who are pregnant should consult their physician before 

    measuring their blood pressure themselves. Different values 

    may be obtained due to their condition.

      of simultaneously used monitoring equipment on the same limb.
13.A compressed or kinked connection hose may cause continuous 
     cuff pressure resulting in blood flow interference and potentially 
     harmful injury to the patient.

14.Check that operation of the unit does not result in prolonged 
      impairment of the circulation of the patient.

Summary of Contents for BP2116

Page 1: ...regularly indicate abnormal readings 3 If you are taking medication consult with your physician to determine the most appropriate time to measure your blood pressure NEVER change a prescribed medication without first consulting with your physician 4 Individuals with serious circulation problems may experience discomfort Consult your physician prior to use 5 For persons with irregular or unstable c...

Page 2: ...d left wrist See Figure C 3 Plastic Storage Case Blood Pressure Classification Indicator Monitor Unit Systolic Blood Pressure mmHg kPa No M D Time Date Pulse Rate Low Battery Indicator Blood Pressure Classification Indicator Systolic Blood Pressure Diastolic Blood Pressure Diastolic Blood Pressure 2 Owner s Manual Contents Figure B Figure A 1 Monitor Unit Owner s Manual Wrist type Fully Automatic ...

Page 3: ...l 2 new AAA alkaline batteries according to polarity Close battery cover Note 1 2 Batteries should be removed from device when not in operation for an extended period of time Replace batteries when Low Battery Indicator appears on screen Applying The Wrist Monitor Do not apply over clothing If wearing a long sleeved shirt be sure to roll sleeve back to forearm Apply monitor to wrist as illustrated...

Page 4: ...esponding cuff pressure value A flashing will appear simultaneously on screen signaling heart beat detection Note Remain relaxed during testing Avoid speaking or moving body parts 4 Result Display Three short beeps sound when testing is complete The screen will display measurements for systolic and diastolic blood pressure An indicator representing the current measurement will appear Indicator mmH...

Page 5: ...alls of arteries It is typically measured in millimeters of mercury mmHg Systolic blood pressure is the maximum force exerted against blood vessel walls each time the heart beats Diastolic blood pressure is the force exerted on blood vessels when the heart is resting between beats An individual s blood pressure frequently changes throughout the course of a day Excitement and tension can cause bloo...

Page 6: ... better reflect your daily life Readings can be elevated when taken in a clinical or medical environment This is known as White Coat Hypertension and may be caused by feeling anxious or nervous Note Abnormal test results may be caused by 1 Improper cuff placement Make sure cuff is snug not too tight or too loose 2 Improper body position Make sure to keep your body in an upright position 3 Feeling ...

Page 7: ...duct Waste Electrical Electronic Equipment This marking shown on the product indicates that it should not be disposed with other household waste at the end of its life To prevent potential harm to the environment or to human health please separate this product from other types of wastes and recycle it responsibly When disposing this type of product contact the retailer where product was purchased ...

Reviews: