background image

dina.de

SAFEONE  

DNSR-2R  

Time Delay Relay

Hardware

Safety switching device for enabling and 
time delayed enabling of control circuits

Summary of Contents for 33SR10

Page 1: ...dina de SAFEONE DNSR 2R Time Delay Relay Hardware Safety switching device for enabling and time delayed enabling of control circuits...

Page 2: ...n and translation of this documentation or parts thereof as well as the storage and processing of this content using electronic data processing systems The information contained in this documentation...

Page 3: ...2 2 1 Electrician 8 2 2 2 Electrical designers 8 2 3 Intended use and improper use 9 2 3 1 Certification data 9 2 4 Documentation 10 2 5 Safety regulations 10 2 5 1 Retrofitting and conversion 11 2 5...

Page 4: ...7 4 Contact outputs 19 7 5 General data 19 7 6 Connection data 20 7 7 Environmental conditions 20 7 8 Dimensions 20 7 9 Safety technical data 20 7 10 Safety related parameters in accordance with DIN...

Page 5: ...l shock dangerous voltage Triangular symbols indicate the type of hazard in warnings Information Additional clarification Tip Additional information to help optimize the workflow 1 1 2 Emphasizing par...

Page 6: ...value your opinion We do all we can to provide complete accurate documentation for the product If you have any suggestions for improvement or advice for us please share your thoughts with us Send us y...

Page 7: ...truction the hazard is present during the next step 2 1 2 Design of warnings All warnings are indicated by a signal word and a warning symbol The different combinations of the signal word and warning...

Page 8: ...oduct A specialist is a person whose specialist training means that they have the knowledge and experience includ ing knowledge of relevant regulations necessary to assess the work assigned to them an...

Page 9: ...ained or incorrectly operated the manufacturer will not assume any liability for any damage that results In this case the risk shall be borne exclusively by the user 2 3 1 Certification data The produ...

Page 10: ...ned instructed person who is familiar with these operating instructions and the applicable specifications regarding occupational health and safety and accident prevention WARNING Danger to persons and...

Page 11: ...ays be complied with In the event that these safety regulations are not complied with or the device is used improperly DINA Elektronik GmbH accepts no liability for any resulting injury or damage The...

Page 12: ...re the product is installed must correspond to the EMC section of DIN EN 60204 1 If contact outputs are used the safety function must be requested at least once per month for Performance Level e and o...

Page 13: ...fschlugen Deutschland Produkt Product Funktion Function DNSR 2R Sicherheitsschaltger t safety switching device ID No 33SR10 33SR11 33SR12 33SR13 33SR14 Zeitrelais time relay Weitere EU Richtlinien Fur...

Page 14: ...V DC A2 Operating voltage 0 V S11 Output control voltage 15 V S21 Output control voltage 12 V S12 Input starting circuit 1 S22 Input starting circuit 2 14 Diagnostic contact 1 NO contact 24 Diagnostic...

Page 15: ...SR10 33SR12 37 38 1 5 s 1 5 s off delay off delay 47 48 1 5 s 50 s on delay on delay 3Open starting circuit 2 S21 S22 7Enabling contact 47 48 opens without delay 4 2 2 33SR11 3Close starting circuit 1...

Page 16: ...es 33SR13 37 38 1 5 s on delay 47 48 180 s on delay 3Open starting circuit 2 S21 S22 7Enabling contact 47 48 opens without delay 4 2 4 33SR14 3Close starting circuit 1 S11 S12 7Enabling contact 37 38...

Page 17: ...has an LED display indicating Operational readiness Enabling contact status 5 1 LED indicators Key LED on LED off LED flashing Contact our support team at support dina de SAFEONE DNSR 2R State LED ON...

Page 18: ...R 2R 33SR10 33SR11 33SR12 33SR13 33SR14 7 Technical data 7 1 Supply Operating voltage UB 24V DC 10 Current consumption at 24 V 40 mA in rest position 70 mA in working position Power consumption on A1...

Page 19: ...V DC13 at 0 1 Hz 4 A 24 V AC15 3 A 250 V Mechanical service life 107 switching cycles 5 x 107 switching cycles Contact fuse 5A gL gG Typical response release time 10ms 6 ms 7 5 General data Type of pr...

Page 20: ...es Stripping length 8 mm Min max tightening torque 0 5Nm 0 6Nm 7 7 Environmental conditions Operating temperature 10 C to 60 C Storage temperature 40 C to 85 C Altitude of place of use 2000 m above se...

Page 21: ...EN ISO 13849 1 2016 06 Category 1 Performance Level c MTTFd a 98 PFHd 4 3E 08 Service life 240 months 7 11 Contact life Electrical service life of the output contacts in accordance with DIN EN 60947...

Page 22: ...756 2 953 in 1 Top hat rail 2 Locking slider 3 Cable duct Procedure 3 Hook the module onto the top hat rail and press it downward 7 The locking slider 1 engages under the top hat rail 8 2 Removing a...

Reviews: