background image

                                                                                                                                                                                                           
A12-51007 V1.0                                                               

 

 

 

 

 

 

 

Floor / Pallet Scale 

 
 

DWP-5500R (Floor Scale) 

DWP-102E (Indicator) 

 

User Manual 

 
 

 

 

 

Summary of Contents for DWP-10000R

Page 1: ...A12 51007 V1 0 Floor Pallet Scale DWP 5500R Floor Scale DWP 102E Indicator User Manual ...

Page 2: ... FUNCTIONS 2 3 CONNECTING LOAD CELL TO INDICATOR CHAPTER 3 OPERATION 3 1 POWER ON ZERO SETTING 3 2 MANUAL ZERO SETTING 3 3 TARE 3 4 ACCUMULATING 3 5 COUNTING 3 6 USER FUNCTION STEETING 3 7 CONNECT SCOREBOARD TO INDICATOR 3 8 SERIAL COMMUNICATION AND INDICATOR COMMECTION CHAPTER 4 SETTING PARAMETERS CHAPTER 5 CALIBRATION CHAPTER 6 ERROR INDICATION ...

Page 3: ...2 Accuracy Grade Ⅲ n 5000 3 Sample Rate 10 times second 4 Load cell sensitivity 1 5 3mV V 5 Scale interval 1 2 5 10 20 50 for option 6 Display 6 bits LED 6 state indicating signals 7 Power supply Battery DC6V 4AH 8 Operating temperature humidity 0 40 90 RH 9 Transporting temperature 20 50 ...

Page 4: ...hapter 2 Installation 2 0 SCALE BASE SETUP a Open the scale base box Box 1 with a knife very carefully Sharp blade may scratch the scale surface b Take out the scale feet total 4 feet packed in the box inside the scale base ...

Page 5: ... or enter the function and save the setting values of parameters In counting mode press to view unit weight counts and total weight when F3 Key 1 In the accumulation mode press to view numbers when F3 Key 2 Press to enter exit animal mode when F3 key 5 MOD Enter exit counting mode when in weighing mode when F3 Key 1 Accumulate and print when F3 Key 2 Hold release the readout when F3 Key 3 Enter pr...

Page 6: ...hen it will enter weighing mode 3 1 2 When powered on if loading weight on the scale deviates from the zero point but still within zero set range the indicator will set zero automatically if it is out of range it is necessary to adjust the zero point or recalibrate or reset 3 1 3 Press UNIT button to select your weighing unit There is indication on the readout panel showing the current weighing mo...

Page 7: ... is 200 Clear the scale platform and press FUN key to view the number of loads and total weight Press ZERO key to clear the memory 3 6 WEIGHT HOLDING FUNCTION WHEN F3 KEY 3 Press MOD key to hold the readout press MOD again to release 3 7 PRE TARE FUNCTION WHEN F3 KEY 4 Press MOD key to enter Pre pare Setting Press ZERO to move the editable digit blinking and press TARE to change the value Make the...

Page 8: ...o 3 10 PRINTING WHEN F3 KEY 2 Set P 10 as RS We will show to how to set P value later on In the weighing mode press MOD to print Chapter 4 Setting Parameters To enter parameter setting Turn on the indicator and press ZERO key when the indicator is still warming up 4 1 F1 CLK DATE AND TIME SETTING Press FUN key to show the current time If it is not correct adjust it as following Press ZERO key to c...

Page 9: ...word 0000 Then press FUN to enter the calibration P1 SP Set AD converting speed Options 1 2 3 4 5 1 is the fastest and 5 is the slowest P2 AUT Set Power on Zero Range Options 0 2 5 10 20 50 100 of the capacity P3 RAN Set Manual Zero Range Options 2 4 10 20 50 100 of the capacity P4 AZ Set Auto Zero Range Options 0 25d 0 5d 1d 2d 4d Off d division P5 DEC Set the decimal points Options 0 0 0 0 00 0 ...

Page 10: ... password Press FUN to confirm Screen will show done Chapter 5 Calibration Enter Parameter setting P8 Unload Empty the scale platform Wait until the STAB sign is on press FUN Input the calibration weight value and press FUN Load Place the calibration weight on the platform wait until the STAB sign is on press FUN The indicator will go to weighing mode when the calibration is completed Chapter 6 Er...