background image

When the scale is on, press                to turn off the scale. 

On/off 

3.2 Pre-Calibration

 

To calibrate the scale please follow these instructions: 
First remove all objects from the platform, then press 

 

to set the display to zero. Press         the display will show 
“SCALE” or “LINE”. “SCALE” means to calibrate the scale 
sensitivity (normal calibration); “LINE” means to calibrate the 
scale linearity. Press        to confirm (If you press       , 
the two kinds of calibration can be interchanged. Please 
proceed to the next step below) 

3.2.1 Sensitivity (regular) calibration 

When calibrating the scale sensitivity, two different weight 
values can be used. According to the shown calibration weight 
value (ie 20.000) on the display, press       , to select which 
calibration weight value you want to use, then press           

to confirm. The display will now show “

0

”. In a few seconds, 

the display will change back to the calibration weight value (ie 
20.000). Place the correct calibration weight on the center of 
the platform.   
In a few seconds, the display will stop, and then show the 
calibration weight value again (ie 20.000). This means 
calibration is complete.   

3.2.2 Linear calibration

 

When the display is showing “LINE”, press       ,the scale will 

display “

0

”. In a few seconds the scale will show 1/3 (or1/2) of

 the 

weight value of it’s full capacity (ie 10.000); put the corresponding 

weight on the center of the platform. 

In a few seconds, the full capacity 

weight value will be shown(ie 30.000). place 

the corresponding 

weight(30g) on the center of the platform. 

In a few seconds the display 

will stop flashing and it will show the original calibration weight value   

(ie 30.000). Calibration is complete. 

NOTE: The scale linearity has been calibrated at the factory, 
this type of recalibration is not necessary unless you need to 
change or alter the loadcell or adjust for certain types of 

environments, 

damage or errors.   

Tare

3.3 Changing Weighing Units 

Light 

With the scale powered ON, , press       to change between 
the following units: 

Units

g

oz

ozt

dwt

gn

ct* 

Units

Tare

 

Note that the Gempro 250 has two Carat modes. One 
reads in 0.001g/0.005ct increments and the other 
reads to 0.002g/0.01ct. This was done so that jewelers 
can choose which accuracy they require for their use. 
We suggest to use 0.002g/0.01ct when possible for 
maximum accuracy. Programming instructions are 
shown later in this manual. 

Units

Tare

Note: The scale has last unit memory, so when you turn it off 
and back on it will show the last unit used. 

3.4 Tare 

With the scale powered ON, press       to set the display to 
zero. 

Tare

3.5 Backlight 

Press                  twice 

F1

    will appear, and the light (10d) may 

turn on automatically. 

Light 

Tare

Press              to  select 

F2

, this means the backlight is always 

on; 

Units

 

Press              to  select 

F3

, this means the backlight is always 

off ; 

Units

 

Press              to confirm, the backlight can be set to different 
states. 

Tare

 

Reviews: