Installation Instructions

Renaissance

®

 Electric Range

Part No. 108559 Rev. C

Models:  RNR30NC[-C], RNR30NFC[-C], RNR30NIC[-C] and RNR30NIFC[-C] 
 

RNR30NS[-C], RNR30NFS[-C], RNR30NIS[-C] and RNR30NIFS[-C]

with induction cooktop

Summary of Contents for RNR30NC[-C]

Page 1: ...Installation Instructions Renaissance Electric Range Part No 108559 Rev C Models RNR30NC C RNR30NFC C RNR30NIC C and RNR30NIFC C RNR30NS C RNR30NFS C RNR30NIS C and RNR30NIFS C with induction cooktop ...

Page 2: ...cor com Dacor Distinctive Service for repairs under warranty only Phone 800 793 0093 extension 2822 U S A and Canada Monday Friday 6 00 a m to 5 00 p m Pacific Time Product Data Label Location The product data label can be seen through the grill below the control panel on the right side Model Identification Product data label view through right side of grate with flashlight Model Configuration Han...

Page 3: ...death WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may result in overheating of the appliance WARNING NEVER cover any slots holes or passages in the oven bottom or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause a fire hazard Aluminum foil linings may also trap heat causing a fire hazard WARNI...

Page 4: ... play with the controls pull on the handle or touch other parts of the range Do not store items of interest to children on top of or above the range Children could be burned or injured while climbing on the appliance Some products such as whole eggs and sealed containers such as closed glass jars may explode and should not be heated on this cooktop Clean the cooktop thoroughly before operating it ...

Page 5: ...wire conduit where local code permits connected to a 3 wire junction box Suggested conduit wiring color code black white red and green Using an appliance cord A 4 wire appliance cord equipped with a NEMA 14 50P plug connected to a NEMA 14 50R receptacle or A 3 wire appliance cord where local code permits equipped with a NEMA 10 50P plug connected to a NEMA 10 50R receptacle Appliance cord plug mus...

Page 6: ...inless steel trim piece in place of a backguard A 6 inch backguard may be purchased as an optional accessory Add an additional 1 16 inch to the depth dimensions above when installing a backguard on models RNR30NIx and RNR30NIFx The trim on models RNR30Nx and RNR30NFx are not compatible with a downdraft vent Models RNR30NIx and RNR30NIFx are compatible with Dacor downdraft vent model ERV3015 only x...

Page 7: ...s for minimum clearances If cabinet storage space is to be provided directly above the range the risk of personal injury may be reduced by installing a range hood The range may be installed flush to the rear wall Dacor recommends installing a non combustible material on the rear wall above the range and up to the range hood or cabinet whichever is lower Any openings in the wall behind the applianc...

Page 8: ... 20 3 8 to 23 3 8 Top View Slide In Self Rimming Installation 3 Side Panels Removed Min Required Cabinet Depth 23 3 8 Cabinet Cutouts for Self Rimming Installation Models RNR30NIx and RNR30NIFx Only 1 To create a built in look on the front of the cabinet this dimension may be changed to 29 1 4 74 3 cm with the width at the notches remaining 30 1 16 This configuration is only for models RNR30NIx an...

Page 9: ... 1 cm Cabinet Cutouts for Self Rimming Installation with Downdraft Vent Models RNR30NIx and RNR30NIFx Only 2 To create a built in look on the front of the cabinet this dimension may be changed to 29 1 4 74 3 cm with the width at the notches remaining 30 1 16 This configuration is only for models RNR30NIx and RNR30NIFx with the side panels behind the door removed Trim kit PN ATKR30SR is required fo...

Page 10: ...ew size required The minimum full thread depth portion of screw threaded into wood slab for wood is 3 8 1 cm and 5 8 1 6 cm for concrete See the table below to select the correct screw size Sub Floor Type Floor Covering Thickness Screw Size Concrete or wood sub floor no floor covering over top 8 x 1 Concrete or wood sub floor floor covering up to 1 4 thick 8 x 1 Concrete or wood sub floor floor co...

Page 11: ...thod may not be used and the floor mounting method must be suitable or the wall must be modified so that the base plate is above the notches 4 To install the bracket place it against the wall in the mounting location shown below Using a drill with 1 8 diameter drill bit drill four 4 1 5 8 deep pilot holes perpendicular to the screw seating surfaces shown Attach the bracket to the wall as shown wit...

Page 12: ... electric shock hazard and damage the appliance Dacor is not responsible for damages resulting from improper installation This range must be connected to a grounded metallic permanent wiring system Alternatively a grounding conductor should be connected to the grounding terminal or lead on the appliance Do not use a 3 wire connection unless local building codes permit Do not turn on power to the a...

Page 13: ...to place 5 Connect the white wire to the neutral terminal inside the box 6 Connect the black wire to the L1 power supply terminal 7 Connect the red wire to the L2 power supply terminal 8 If using a 4 wire connection connect the green wire to the grounding screw inside the box 9 Replace the range electrical access cover Installation Instructions Bare wire connections Loop and spade terminal connect...

Page 14: ...he appliance to the neutral white supply wire inside the junction box 3 Connect the black wire from the appliance to the black L1 power supply wire inside the junction box 4 Connect the red wire from the appliance to the red L2 power supply wire inside the junction box 5 If using a 4 wire connection connect the green wire to a grounded supply wire in the junction box or to a grounded cold water pi...

Page 15: ...e Conduit Junction Box Connection with External Ground Separate No 10 minimum copper grounding wire Wire nut 4 places Conduit to appliance Conduit to appliance Wire nut 3 places Junction box Junction box 3 Wire Conduit Junction Box Connection Connection to house power supply Connection to house power supply ...

Page 16: ...stallation Instructions Electrical Connection cont Appliance Cord Connections Where Local Code Permits WARNING Do not connect the green appliance wire to the neutral white supply wire unless local building codes permit 1 If using a 4 wire connection loosen the grounding screw and remove the neutral to ground jumper link 2 Remove the conduit bracket from the bottom of the range electrical box 3 Dis...

Page 17: ...Jumper link Link removed Ground screw L2 terminal L2 terminal L1 wire L1 wire White wire White wire Green wire L2 wire L2 wire Strain relief Strain relief 3 Wire Appliance Cord Connection Where Local Codes Permit 3 Wire Appliance Cord Plug 4 Wire Appliance Cord Plug 4 Wire Appliance Cord Connection Where Local Codes Permit ...

Page 18: ...stallation since the range top overhangs the countertop cutout 1 Measure from the floor to the countertop 2 Adjust the leveling legs to position the bottom edge of the range top trim at countertop height 3 Carefully slide the range into position in the cutout As you slide the unit into place the rear leg should engage the anti tip bracket 4 Using a flashlight look underneath the range and verify t...

Page 19: ...l 3 Prior to operating the range read the accompanying use and care manual carefully Important safety service and warranty information are contained within 4 Turn on power to the range at the circuit breaker panel or fuse box 5 Set the clock according to the use and care manual 6 Press the BAKE key on the control panel The default bake temperature should appear on the display 7 Press START After a...

Page 20: ...orm the following checklist to ensure that no part of the installation has been overlooked Proper installation is the responsibility of the homeowner 1 Has the plastic coating been peeled off of the outside of the range Have all packaging materials been removed from inside the oven 2 Are all of the legs extended down to make contact with the floor Is the unit level See page 16 3 Is the range secur...

Page 21: ...19 Notes ...