background image

 OPERATING INSTRUCTIONS

Multifunction Timer

Item no. 39 39 03: „MFT1816-12 V“
Item no. 39 39 04: „MFT1816-24 V“

Version 03/13

Summary of Contents for MFT1816-12 V

Page 1: ...OPERATING INSTRUCTIONS Multifunction Timer Item no 39 39 03 MFT1816 12 V Item no 39 39 04 MFT1816 24 V Version 03 13...

Page 2: ...ay Functions 10 1 Switch Off Delay 10 2 Switch Off Delay Resettable 10 3 Switch On Delay 10 4 Switch On Switch Off Delay 11 5 Switch On Switch Off Delay Resettable 11 c Sequence Functions 12 1 Alterna...

Page 3: ...s on commissioning and handling Also consider this if you pass on the product to any third party Therefore retain these operating instructions for reference All company names and product names are tra...

Page 4: ...3 VCC GND SET SET RESET RESET SEQ J4 1 2 3 4 5 6 7 GND J1 Optocoupler inputs polarity does not matter switching e g via buttons J3 Connection of the Voltcraft USB programming cable R3 Potentiometer se...

Page 5: ...Step button REL REL SEQ OFF Step button with switch off delay REL SEQ Each 00 00 01 01 30 00 Logical operations AND OR XOR Power surge switch Presence simulation randomly controlled Max 00 00 02 01 3...

Page 6: ...ed by Cancel data transfer is not possible Selection and Transmission of a Function After confirmation of the language and COM port settings the programme offers a selection of different switching fun...

Page 7: ...at once When the button at the input SET is released again the relay remains activated for the set time T1 The push of a button at the input RESET deactivates the relay output Optional functions only...

Page 8: ...ted another push of the button at the input SET deactivates the relay output at once 3 Short Push of the Button Time Extension Long Push of the Button 3s Immediate Shut Down If the relay is already ac...

Page 9: ...sh of a button at the input RESET deactivates the relay output immediately 2 Service Function The button at the input SET must be kept pushed for 5 seconds requirement The relay is deactivated Then th...

Page 10: ...The relay is activated at once When the button at the input SET is released again the relay remains activated for the set deactivation delay T1 If the button at the input SET is pushed again during t...

Page 11: ...the relay output immediately 5 Switch On Switch Off Delay Resettable If the button at the input SET is pushed a positive level is pending and the set switch on delay T1 will start at once After the en...

Page 12: ...set the function is re started if the button at the input SET is pushed starting with activated relay outputs 2 Alternating Button REL SEQ OFF Operation of the button at the input SET toggles the cond...

Page 13: ...ted relay outputs 4 Step Button with Switch Off Delay Operation of the button at the input SET toggles the switching condition of the device in the order Relay on Sequence on Completely OFF with adjus...

Page 14: ...FF OFF ON OFF ON OFF OFF ON ON ON OR OFF OFF OFF OFF ON ON ON OFF ON ON ON ON XOR OFF OFF OFF OFF ON ON ON OFF ON ON ON OFF The inputs SET and RESET can be used as logical inputs for the operation fun...

Page 15: ...nce starting with the activation time T1 The two times are random values between the minimum and maximum time entered by PC software If the button at the input SET is pushed while the function is alre...

Page 16: ...an be set independently If the button at the input SET is pushed a positive level is pending and the relay is activated at once The relay is activated or deactivated according to the respective switch...

Page 17: ...ction by any method e g photocopy microfilming or the capture in electronic data processing systems require the prior written approval by the editor Reprinting also in part is prohibited These operati...

Reviews: