Fuse Link Specifications: 

 
The Terminal unit is equipped with a built in fuse link.  If an 
overcurrent condition were to occur, the chassis will act as a 
fuse chamber, greatly reducing any threat to safety.  Once 
fuse links have been fused, they cannot be rehabilitated or 
repaired. 
 

4.0 

Installation Data: 

 
 

 
The Terminal should be installed to the network’s standard 
installation procedure.  However, the following factors should 
be considered. 

 
4.1 

 
Use care when unpacking the Terminal from its shipping 
carton to avoid damage to the Terminal, modules, or 
connectors. 

 
4.2 

 
Install the Terminal as close to the incoming entrance cable as 
possible. 

 
4.3 

 
The Terminal can be mounted on any level, uniform vertical 
surface. 

 
4.4 

 
Install the Terminal where it will be accessible to technicians at 
all times without the terminal obstructing individuals or 
equipment. 

 

Note:

 Although the Terminal is designed to withstand extreme 

conditions, it is always best to avoid any unnecessary 
problems by observing the following important notes: When 
installing the Terminal, it is highly recommended that unit be 
placed in a non-combustible area.  (The environment 
surrounding these devices should not contain flammable 
materials such as curtains, carpeting, etc.)  

 

If the installation for the telco equipment is not in an assigned 
electrical room, it is advised to avoid areas with dust, moisture, 
extreme environmental conditions, heavy traffic areas requiring 
rolling machinery, pipes used to transport water, fuel, and 
gases. 

 
4.5 

 

Avoid exposing the Terminal to chemicals or cleaning liquids, 
which could damage various plastic components within the 
device. 

 
5.0 

 
Installation Procedures: 

 

 

Mount the Terminal to a surface using the supplied mounting 
screws or approved network standards screws. 

 
5.1 

 
Outside Plant Termination (Incoming/ QCBIX®): 

 
To terminate the entrance cable pairs to the incoming QCBIX® 
connector, the procedure is as follows: Refer to figure 1 for 
QCBIX® connector arrangements.  The pairs should then be 
jumpered to the QCBIX® connector using a QTBIX16A 
termination tool.

Caution:

 Do not use a screwdriver for 

attaching line pairs to QCBIX® terminals, as a screwdriver 
may spread the clip beams and result in a faulty connection. 
 

5.2 

Distribution Termination (Outgoing/ QCBIX®): 

 
The procedure for terminating the distribution cable pairs onto 
the outgoing QCBIX® connector is the same as indicated in 
5.1, except the cable pairs are routed to the “OUT” terminal. 

 
6.0 

 
Grounding: 

 
A #6 AWG wire should be connected from the Terminal ground 
lug to a local ground as per network standard methods.  It 
should be noted that incorrect bonding, grounding or standards 
would result in terminal and protection module failure. 

 
7.0 

 

Terminal Module Installation: 

 
 

 
If the Terminal is purchased with the terminal modules 
installed they will be inserted in the terminal panel in the detent 
position. A distinctive “notch” in the three long pins of the 
module indicates the detent position.  This will connect the 
incoming tip / ring as well as grounding circuits of the module. 

 

 

Note:  When the module is in detent position it will protect 
only the incoming (outside plant) cable.  The module must 
be fully inserted to provide protection to both the central 
office and customer premise side of the installation. 

 
7.1 

 
After all incoming and outgoing connections are completed; 
fully insert the terminal module until the base of the module 
meets the terminal block.  This will connect the distribution 
termination (Outgoing/ QCBIX®) side of the unit to the outside 
plant (Incoming/ QCBIX®) side of the unit. 

 
7.2 

 
Fully test all connections. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

8.0 

Terminal Diagram: 

 
 

6

1

OUT

IN

5.0

3.9

6.45

 

 

 

Important Note: 

 
All statements, technical information and recommendations related to the 
Seller’s products are based on information believed to be reliable, but the 
accuracy or completeness thereof is not guaranteed.  Before utilizing the 
product, the user should determine the suitability of the product for its intended 
use.  The user assumes all risks and liability whatsoever in connection with 
such use.  Any statements or recommendations of the Seller, which are not 
contained in the Seller’s current publications, shall have no force or effect 
unless contained in an agreement signed by an authorized officer of the Seller.  
The statements contained herein are made in lieu of all warranties, express or 
implied, including but not limited to the implied warranties of merchantability 
and fitness for a particular purpose which warranties are hereby expressly 
disclaimed. 
Seller shall not be liable to the user or any person under any legal theory, 
including but not limited to negligence or strict liability, for any injury or any 
direct or consequential damages sustained or incurred by reason of the use of 
any of the Seller’s product that were defective. 

2406B-6 