background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCD Keypad User's Guide 

rev1.3

 

 

 

 

 

 

 

 

 

 

Attention: Security Representative / Installer, 
Please give this guide to the customer before beginning work on the system. 
 

 

 

 

 

 

Summary of Contents for MONITOR AFx

Page 1: ...LCD Keypad User s Guide rev1 3 Attention Security Representative Installer Please give this guide to the customer before beginning work on the system ...

Page 2: ......

Page 3: ...tion 12 UK and European System Operation 12 Checking Status and Controlling Items 15 Status and Control Features 16 Using the Function Keys 16 Checking the System Status monitored conditions for a system control unit 16 Checking the Status of Sensors Points and Areas 17 Bypassing or Isolating a Faulty Sensor 17 Checking Status or Controlling Readers or Doors 18 Checking the Status or Controlling a...

Page 4: ...ad User s Guide 500 3650E rev1 3 Residential Fire Safety Evacuation Plan 34 Arming Station Reference 36 Wireless Keypad Reference 39 Error Messages and Trouble Indications 40 Things to Do to Prevent False Alarms 41 Index 42 ...

Page 5: ...r Equivalence Number REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five The REN for the Chubb AFx using the Nor...

Page 6: ...he telephone company may request that you disconnect the equipment until the problem is resolved There are no user serviceable parts which may be repaired by the customer All repairs must be performed by an authorized dealer representative This equipment cannot be used on public coin phone service provided by the telephone company Connection to party line service is subject to state tariffs Contac...

Page 7: ...e Criteria IEC 1000 4 2 EN 61000 4 2 Electrostatic Discharge 6kV Contact Discharge direct and indirect 8kV Air Discharge A A IEC 1000 4 3 EN61000 4 3 ENV 50140 240 Radiated RF Immunity 10V m 80 2000 MHz 1 kHz 80 AM modulation 10V m 80 2000 MHz Pulse Modulation with 1 Hz Square A A IEC 1000 4 4 EN 61000 4 4 Electrical Fast Transient 2kV on AC lines 1kV on DC I O lines A A IEC 1000 4 5 EN 61000 4 5 ...

Page 8: ... ...

Page 9: ...talled Ask your Security Representative Installer to explain any questions that you may have about the various topics It is important to check the section at the back of this booklet that will list information about your alarm system named Reference Topics Ask your Security Representative Installer to supply the information that should be entered into this section Thank you Welcome ...

Page 10: ...ns under the Display Screen The buttons directly under the display screen allow selecting associated items on the display screen This means the item displayed on the screen above each button Like the rest of the keypad these buttons are backlit for use in poor lighting conditions The Numeric Keypad The main keypad in the bottom left portion of the unit provides a convenient way to enter numbers an...

Page 11: ... following topics will be available Selecting a Topic Press the key until your desired topic appears on screen Then press the key directly under your topic to select it Off Stay On The first screen that you ll see allows you to arm or disarm the area s as desired or to access other topics Only two of arm disarm selections will appear at a time depending on the present arming state of the area s Of...

Page 12: ...er the display screen when the arrow È beside desired subjects on the screen is pointing down to the corresponding keypad buttons The and buttons allow you to view additional topics when available and or will appear on the display screen to indicate these keys can be used Use the escape key when finished with your present menu topic to return to the main screen or back out of inner screens Enterin...

Page 13: ...500 3650E rev1 3 Welcome Alarm Status Admin Reference 5 Alarms Turning Protection On and Off ...

Page 14: ...ming Station Reference in this manual Pressing Keypad Keys Buttons Single short beep Error Tones for Wrong Keys Pressed 6 short beeps Fire Alarm Standard and Alternative Operation A quick on and off tone Burglary Alarm Trouble Condition Standard Operation Steady continuous tone Alternative Operation Slow on off tones Entry and Exit Delay tones generated when the protected area is entered or protec...

Page 15: ...elled The following steps assume that you have accidentally triggered a false alarm If an alarm has been generated the LCD display will show the alarm and the keypad sounder will probably also be making a steady tone Steps 1 Enter your user ID and or password to log into the keypad 2 Select Yes to silence the alarm 3 Select Yes again to verify who you are 4 Enter your PIN when prompted This will s...

Page 16: ...or normal business hours If the scheduled closing time is approaching when the protection is turned on and you wish to remain in the area you can extend the closing time Steps 1 Enter your user ID and or PIN to log into the keypad 2 Press the arrow keys until you see Schdule Then select Schdule 3 Select Schd to change the Schedule for the selected area e g Office or select Next Area to select a di...

Page 17: ...ur user ID and or PIN to log into the keypad 2 Select the button for your desired protection level If all areas are currently OFF only STAY and ON are shown If STAY is not an authorized function only ON will be shown The Stay arming level refers to the perimeter sensors being monitored but not the interior ones This is typically used when someone is inside the facility or protected area 3 Select N...

Page 18: ...put in Stay for partial protection 4 After making your selection this screen will ask if the protection for all areas should be changed if there is more then one area If No is selected this screen will display the current condition of the available areas e g On and selections for that area Selections for other areas are displayed by pressing Nxt or just change the protection level for the area you...

Page 19: ... to enter This can make this main entrance a common area Both users can have authority for this common area to reach their particular areas This allows them to be able to turn the protection on and off to this common area when their authorized areas are in use Check with your Security Representative Installer or System Administrator for information and authority for a Common Area Turning ON an Are...

Page 20: ...xit report will be logged in the system s History log UK and European System Operation UL Listed Systems Not to be used for UL listed systems Restoring Tampers Once a tamper condition occurs it will be logged in the system s History log Any authorized users can silence tampers however the following system message will scroll on the LCD display to indicate that a tamper condition had occurred This ...

Page 21: ...nt than arrangements should be made to have them corrected Remote Reset For customers who would rather reset the ACPO alarm themselves instead of a service engineer person attending and doing it When the ACPO alarm occurs the LCD keypad screen will display a 6 digit code The customer notifies the monitoring station with this number The monitoring station enters the number in this program s Custome...

Page 22: ...14 Chubb AFx LCD Keypad User s Guide 500 3650E rev1 3 ...

Page 23: ...500 3650E rev1 3 Welcome Alarm Status Admin Reference 15 Checking Status and Controlling Items ...

Page 24: ...ty may need to enter their ID PIN numbers to be allowed to use these function keys This requirement can be assigned as necessary to any areas Check with your security representative To log in open the keypad cover and key in your user ID number and or PIN number as indicated on the display Then press and hold the F key and press the desired number at the same time Checking the System Status monito...

Page 25: ...ulty Sensor If the system or a specific area needs to be armed with a faulty or insecure sensor you will need to bypass the problem sensor Steps 1 Enter your user ID and or PIN to log into the keypad 2 Scroll the left and right arrow keys until Bypass appears on the display Press Ok An area s sensor cannot be bypassed if the area is ON You can also bypass sensors through the Points status screens ...

Page 26: ...and right arrow buttons to scroll the items 4 Select Doors and press Ok 5 Select the desired topic Door For doors in the displayed area Next Show the next area All All doors regardless of area 6 Now select Door or Readers as desired Press this key to scan through the doors in the system or the selected area Door Door status or commands to unlock or relock the door or lockout or reinstate all cards...

Page 27: ... Checking a specific aspect of an elevator reader can be performed through the keypad such as checking if it is in Card Plus PIN mode but you will have to log in at a Director software PC to see if the floors are secure Checking the Status of an Application Module POD You can check the status of any application modules in the system An application module provides increased functionality such as Pr...

Page 28: ...20 Chubb AFx LCD Keypad User s Guide 500 3650E rev1 3 ...

Page 29: ...500 3650E rev1 3 Welcome Alarm Status Admin Reference 21 Administration and Maintenance Tasks ...

Page 30: ...ntrolled doors Steps 1 Log into the keypad by entering your user ID and or PIN as indicated on screen 2 Press until Users appears press Ok 3 Enter an available user number and select Ok or select Ok and then press until a user number appears with Add instead of Edit and Delete 4 Undfnd Undefined Select Add In this screen refers to systems with Suite Security keypads allows viewing the user s Suite...

Page 31: ...est 9 9 Service Test 9 Silence Alarm 9 9 9 9 Status 9 9 9 9 9 History 9 9 Function Key Authorization 9 9 Work Late 9 9 9 9 Suspend Schedule 9 9 On 9 9 9 9 9 Off 9 9 9 9 Stay 9 9 9 9 Auto Disarm to Off 9 9 Auto Disarm all Areas 9 9 Access Access when Area is Off On Stay 9 9 9 9 9 Escort 9 Master Override 9 Reset Door Alarm 9 9 Door Command 9 9 9 Class A 9 9 9 9 9 Class B 9 9 9 9 9 Class C 9 9 9 9 9...

Page 32: ...our Security Representative Firmware revisions needed for 9 digit card IDs or cards with version numbers Panel firmware V3 2 and door elevator controller firmware V1 5 PIN This allows setting or changing the Personal ID Number for this user You ll be asked to enter it twice to help protect against typing errors The last two digits of the PIN must be different Also do not use consecutive numbers li...

Page 33: ...then enter the letter as before Aut Use the Next and Prev buttons to select an authority profile for the user Select Ok when finished This determines what doors the user can enter and at what time of day and the tasks they will be able to perform at system keypads Setting this as Undfnd will delete the user User authority profiles themselves are normally set up by your service technician service P...

Page 34: ...nute Setting the Date and Time The panel date and time can be set through an LCD keypad if necessary Service Test authority is required to set the date and or time For a reference of the dates to automatically switch between standard time and daylight savings time refer to Holidays and Time Change Dates in the Reference section Steps 1 Enter your user ID and or PIN to log into the keypad 2 Use the...

Page 35: ...e recorded Viewing an area s history requires authority for that area Steps 1 Enter your user ID and or PIN to log into the keypad 2 Use the left and right arrow buttons to scroll the items until History appears and press Ok 3 Select All for a complete list or Category for history referring to an Area Condo Suite Security keypad or Application module e g Printer Press Ok 4 If you selected Category...

Page 36: ...You may also need to turn the printer off to clear its memory Plog Prints the entire history log To return to the main screen log out press the escape key a few times or let the system time out 1 minute Changing the Printed History Language You can change the language for the printed history log when needed Check with you Security Representative Installer to confirm your system version is capable ...

Page 37: ...teps 1 Enter your user ID and or PIN to log into the keypad 2 Use the left and right arrow buttons to scroll the items until Test appears and press Ok 3 When Area appears press Ok 4 Choose from the following selections Test To test the displayed area Next Area To jump to the next area 5 Select Walk to perform a Walk Test of this area 6 At this time you can proceed to test the protection points in ...

Page 38: ...e 6 Select End when finished viewing and or to select another area to test To return to the main screen log out press the escape key a few times or let the system time out 1 minute Testing Sirens System Test Test Your System Once a Week Weekly testing of the system s siren bell is required A System Test allows you to test the entire system to ensure security components are functioning properly Thi...

Page 39: ...500 3650E rev1 3 Welcome Alarm Status Admin Reference 31 Reference Topics ...

Page 40: ...me sensors or with all the protection turned on When to Contact your Security Representative If there appears to be a fault with the system To order additional protection equipment for installation Like a contact for a new door smoke sensors motion detector for a new room addition etc Protected Area Names Area 1 _____________________________ Area 2 _____________________________ Area 3 ____________...

Page 41: ...tion keys Function Key Assignments F 1 _________________________ F 2 _________________________ F 3 _________________________ F 4 _________________________ F 5 _________________________ also turns chime on and off F 6 _________________________ F 7 _________________________ F 8 _________________________ F 9 _________________________ F 0 _________________________ Door Chime Feature The Door Chime fea...

Page 42: ...may have as little as two minutes to escape from the time the smoke alarm sounds Knowing how to use those minutes wisely can make a life saving difference That s why home fire escape planning is so important Developing and practicing a home fire escape plan will help you snap into action immediately if the smoke alarm sounds so you can get out quickly and safely Escape Plan Guidelines Make sure to...

Page 43: ...ey and closing all doors behind you If the building has a voice enunciation system follow its instructions precisely unless doing so puts you in immediate danger If fire or smoke blocks your exits stay in your apartment and cover all cracks and vents using wet towels duct tape linens clothing and so forth where smoke could enter Telephone the fire department even if firefighters are already at the...

Page 44: ...ction point is bypassable it will be automatically bypassed when arming is done at the station Unless specially programmed all points except the entry exit door ARE bypassable Command Result 2 login Turn area to Stay Command Result 3 login Turn area On Command Result 3 0 login Turn all Areas On Command Result 5 login Door Commands and Disarm area Door Commands If area is off and door unlocked door...

Page 45: ...ard pin UID is not required since the card automatically identifies the uid Card or UID PIN card or uid pin UID PIN Only uid pin If card is presented it will be ignored uid User ID With Commands Door Mode cmd Login Notes Card Only cmd card If a UID PIN is entered it will be ignored Card PIN cmd card pin Card badging must always be done before the PIN entry Card or UID PIN cmd card or cmd uid pin P...

Page 46: ...n 15 minutes to the scheduled closing time Door State Light Red light on solid if the door is locked Same light solid green if the door is unlocked Flashing red while protection turning off if there was an alarm in the area Armed Light On solid green if the area is disarmed Off On solid red if the area is set to the Stay arming level only the perimeter sensors being monitored Flashing red if the a...

Page 47: ...r ID and PIN Command Result login command key 1 Turns area fully Off Command Result login command key 2 Turns area to Stay Command Result login command key 3 Turns area fully On Command Result login command key 4 Performs a System Test All Sirens will sound and all lights turn on for 5 seconds to indicate that the system is functioning correctly Command Result login command key 9 Clears or Silence...

Page 48: ...iguration on module HSC Comms Alarm Communications Trouble If a trouble condition persists contact your Security Representative Installer to investigate Keypad Yellow Trouble Light The Yellow Trouble Light on the keypad may turn on when the following system conditions occur System Tamper Battery Trouble AC Failure Flashing Phone Line Trouble Report Delay Time Lost Time Changed Program Error Fuse T...

Page 49: ...tation Keep your system number and pass number confidential Notify the monitoring station if you did not turn the protection off before the entry time countdown expires Notify the monitoring station immediately if someone accidentally activates a panic button or emergency key Notify the monitoring station immediately if you have accidentally caused a false alarm Notify the monitoring station befor...

Page 50: ...rolling 18 Door Chime 33 Duress Alarm 3 Emergency keys Using 8 Error Messages 40 Evacuation plan 34 Event logs 27 28 False Alarm Cancelling 7 False Alarm Prevention 30 41 Faulty sensor bypassing 17 Faulty sensor Isolating 17 Fire safety 34 Function keys Using 16 Function Keys Reference 33 Group of Areas protection On 10 History printing 28 History viewing 27 Holdup test 30 ID number PIN number 3 1...

Page 51: ...ding schedules 9 System information areas authorities etc 32 System test 30 Testing sirens 30 Testing the Entire System 30 Testing the System Panic buttons holdup test 30 Walk Test 29 Time and date for the panel setting 26 Trademarks and copyrights iii Trouble Light Indications 40 Trouble messages 40 Turning On Off Common Area 11 Turning On Off Priority 11 Unlock relock doors 18 Users Adding 22 De...

Page 52: ......

Page 53: ......

Page 54: ...N3459 ...

Reviews: