OPERATING GUIDE for your

GEM-RP1CAe2 KEYPAD

R

    

AR

M E

D S

TAT

US

  

 





NEXT/YES

PRIOR/NO

AREA

© NAPCO 1997

DESIGN PATS. PENDING

GEM-RP1CAE2.pub 
page 1

Tuesday, September 29, 1998 09:28 

Summary of Contents for Gemini GEM-RP1CAe2

Page 1: ...1 OPERATING GUIDE for your GEM RP1CAe2 KEYPAD R ARMED STATUS NEXT YES PRIOR NO AREA NAPCO 1997 DESIGN PATS PENDING GEM RP1CAE2 pub page 1 Tuesday September 29 1998 09 28...

Page 2: ...afety and security familiarize yourself with this equipment Periodically check its con dition and state of readiness by testing it at least once a week in both the ac battery and battery only modes as...

Page 3: ...KEYPAD MESSAGES 24 GLOSSARY 27 SYSTEM TROUBLE ERROR CODES 28 TO SHUT OFF AN ALARM EN TER YOUR CODE THEN PRESS THE BUTTON FOR SERVICE CALL _________ CENTRAL STATION ___________ EXIT DELAY _____________...

Page 4: ...4 KEYPAD CONTROLS INDICATORS GEM RP1CAE2 pub page 4 Tuesday September 29 1998 09 28...

Page 5: ...isplays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or se lected function to be executed...

Page 6: ...code and press the button The green STATUS light will go off the red ARMED light will come on and the window will alternately display and where represents the exit time remaining in 10 second steps No...

Page 7: ...ll for service as soon as possible Easy Exit Easy Exit programmed YES NO Your System may have been programmed to allow Easy Exit which allows a user to exit the premises with the system armed If the b...

Page 8: ...case the keypad display will normally show the icon except when the system is armed and the Exit Entry door is opened At this time those Interior Zones will unbypass providing complete interior prote...

Page 9: ...n the respective Emergency Button and the button are pressed at the same time Fire Emergency Simultaneously press the and buttons to alert the central station of a fire emergency Auxiliary Emergency S...

Page 10: ...go out Note If you enter a wrong code the keypad will display Re enter your code immediately Alarm Indication If the red ARMED light is flashing and is displayed an alarm occurred while you were out P...

Page 11: ...it door window foil etc A problem on this type of burglary zone will cause a display and a pulsing keypad sounder while disarmed To silence the sounder press the button or arm and disarm if so program...

Page 12: ...utton to turn off the alarm 3 Press the button to silence the keypad sounder 4 Check smoke detector s If a smoke detector tripped its red alarm indicator light will be on 5 After the alarm condition i...

Page 13: ...ilding 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door I...

Page 14: ...14 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan GEM RP1CAE2 pub page 14 Tuesday September 29 1998 09 28...

Page 15: ...slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen levels smoke toxic gases or...

Page 16: ...erating mode if no activity is detected for longer than one minute Note In all UL listed applications and in high security installations only those users having valid codes can access the Function Mo...

Page 17: ...second warning and the keypad will begin a 15 minute countdown with the sounder pulsing During this time arming may be delayed an additional 1 to 4 hours as above or autoarming may be cancelled by arm...

Page 18: ...aborted by dis arming within the delay period 24 Hour Zones and zones pro grammed to report restores must be restored first then the panel armed and disarmed all within the delay period Opening and or...

Page 19: ...press In effect you will now be in that area 3 Enter your code then press to arm code must be valid in that area To arm all areas simultaneously including the area you are in 1 Press the button then...

Page 20: ...ns in the Program Mode While in the Program Mode the ARMED and STA TUS lights remain off and burglar and fire alarm func tions are disabled If the keypad detects no activity in the Program Mode for mo...

Page 21: ...ng the number buttons The cursor will automatically advance to the User Code and read the existing code if any 3 Enter the new User Code directly using the number buttons If an old code is displayed s...

Page 22: ...tons and scroll through numbers letters punctuation marks and a variety of symbols Enter an identifying description for each zone then press the save button To advance to the next zone or to any other...

Page 23: ...then representing the default User Code 2 Using the button position the cursor over the first digit of the User Number 3 Press the to select User 3 press the button to move the cursor to the User Cod...

Page 24: ...xit delay in progress XXX denotes exit time remaining in seconds If displayed S indicates Service Code active I indicates arming with Instant protection Entry delay in progress XXX shows entry time re...

Page 25: ...g sounder Alarm condition on a Fire Zone Press the button to silence sounder Evacuate premises or correct cause of alarm For partitioned systems only Code not valid for area Wrong code entered or Easy...

Page 26: ...ERROR CODES for a complete list of system troubles Check power transformer Check for blown fuse or circuit breaker general power outage Battery weak If not recharged within 24 hours replace battery C...

Page 27: ...ing reports and emergency mes sages from a digital communicator and notifies the proper authorities Chime A keypad beep while dis armed alerting that the programmed zone has been opened Closing Window...

Page 28: ...ck A beep after arming verifying the central station s receipt of a closing report Service Code A code intended for temporary use Sounder A local warning device at each keypad to alert that a entry de...

Page 29: ...rs etc but not exterior doors or win dows These can all be bypassed simultaneously using the button Two groups of Interior Zones may be programmed for each area Priority Zone A zone that pre vents arm...

Page 30: ...nsmitter tamper condition NN transmitter number E16 NN Receiver jammed NN receiver number E17 NN Receiver tamper condition NN receiver number E18 NN Key fob transmitter low battery NN key fob transmit...

Page 31: ...31 NOTES GEM RP1CAE2 pub page 31 Tuesday September 29 1998 09 28...

Page 32: ...have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or...