background image

ELEKTRODENSTEUERUNG ES2001

INSTRUCTION MANUAL

SAFETY INSTRUCTIONS

- Installation, commissioning and maintenance may only be performed by

qualified personnel!

- nly connect the unit to the voltage specified in the technical data or on the type

plate (observe polarity for DC)!

- The device must be disconnected from all sources of power during installation

and maintenance work.

- The device may only be operated under the conditions specified in the operating

instructions.

TECHNICAL DATA

Power supply

230, 115, 48, 24 V ±10% AC 50/60 Hz; 24, 12 V DC

Connected load

≤ 2 VA

Relay output

2 changeover contacts, potential-free
AC: Max. 250 V, 5 A, 500 VA

DC: Max. 125 V, 1 A, 40 W

Measuring circuit

Galvanically isolated, AC voltage < 6 V / < 2 mA

Measuring function

MIN-MAX control
MIN control or MAX control

Hysteresis

About 20% of the set sensitivity value

Response sensitivity

2 adjustable ranges
1 to 70 kΩ & 5 to 150 kΩ

Working principle

Open / Closed curent lopp

Delay

ON/OFF delay adjustable: 0.5 to 3 s
Adjustment through potentiometer

Ambient temperature

-15 ... +45 °C

Dimension

22.5 x 75 x 100 mm

Housing

IP40, mounting DIN rail 35x7.5 mm (EN 50 022); Option: IP55 wall-mount cabinet 88x150x130mm

Cable

min. Wire cross-section 0.5mm², shielded cable

Electrical connections

IP20, screw terminals, cable cross-section max 2.5 mm²

Signalling

1x LED: ''Operating''
1x LED: ''Status of relay''

EC Conformity: The instrument meets the legal requirements of the current European Directives.

OPERATING RANGE

The capacitive resistance of long cables reduces the sensitivity of the detection.

A standard 3-wire PVC cable has a capacitance of 100 pF/m
The range therefore depends on the liquid resistance and on the cable length between the electrode and the relay ES2001.
This results in an operating range according to the diagram below:

Liquid resistance [ kΩ ]

Outside the operating range

Operating range

Cable length [ m ]