background image

ABL Series

A-44

-|Transparent setting guide|-

Relay Terminal Block (screwless type)

[Common Feature]

●Selectable between independent and load common output with jumper bar

●High tensile force and easy wiring with one-touch screwless type crimp terminal

●Convenient operating status check with operation indicator (blue LED)

[1-point]

●Rated load voltage: 3A

●Selectable between independent and power ommon input with jumper bar

●DIN Rail mounting

●Relay: [Fujitsu] NYP24W-K / [Panasonic] APAN3124

[4-point] 

●Rated load voltage: 5A

● Selectable between NPN (+ COM) and PNP (- COM) input with jumper bar

●Relay protection with the cover

●Easy relay replacement with relay ejector or removal lever

●DIN Rail or screw mounting

●Relay:  [Fujitsu] NYP24W-K / [Panasonic] APAN3124, PQ1a-24V /

 

[Omron] G6B-1174P-FD-US

[16-point] 

●Rated load voltage: 3A

●Relay protection with the cover

●Easy relay replacement with relay ejector

●DIN Rail or screw mounting

●Relay: [Omron] G6B-1174P-FD-US

 Features

 Crimp Terminal Specifications

(unit: mm)

A

B

C

Applicable wire

End Sleeve (ferrule terminal) 

crimp terminal

10 to 12.0

≤ 2.0

≤ 4.1

AWG22-16 (0.30 to 1.25mm

2

)

(60

 only)

A

C

B

 

Ordering Information

Terminal block

Item

AB

04 PQ

L

L

U N

N

Not installed

Y

Installed

U

Universal

N

NPN

P

PNP

TN

T

AKAMISAWA(Fujitsu) 

N

YP

PA

MATSUSHITA(

P

anasonic) P

A

PQ

MATSUSHITA (

P

anasonic) P

Q

R6

OM

R

ON G

6

B

01

1

04

4

16

16

L

Screwless

H

Hirose connector

L

Screwless

AB

Relay terminal block

Controller

No. of relay points

Relay type

Input logic

Varistor installation

Please read “Safety considerations” in instruction 

manual before using.

Summary of Contents for ABL Series

Page 1: ...Rail or screw mounting Relay Fujitsu NYP24W K Panasonic APAN3124 PQ1a 24V Omron G6B 1174P FD US 16 point Rated load voltage 3A Relay protection with the cover Easy relay replacement with relay ejector...

Page 2: ...using stranded wire use End Sleeve ferrule terminal crimp terminals 5 In case of ABL L04 Y varistor installed type this is 300VAC 6 The weight includes packaging The weight in parenthesis is for unit...

Page 3: ...ated load current 3A ABL L01TN PA Jumper bar model JB 9 0 04L For the desired application power load common jumper bar is sold separately 4 31 9 27 4 2 2 0 5 1 2 6 12 5 2 ABL L04TN PA Jumper bar model...

Page 4: ...or ABL L04 UY varistor installed type NPN PNP LOAD common are operated by the inserting position of the Jumper bar Please refer to the 2 Using jumper bars of Replacing Relay and Using Jumper Bar Jumpe...

Page 5: ...arts are only for ABL L04 UY varistor installed type NPN PNP LOAD common are operated by the inserting position of the Jumper bar Please refer to the 2 Using jumper bars of Replacing Relay and Using J...

Page 6: ...H16R6 NN ABL H16R6 PN 3 4 1 2 RY1 GND1 24VDC1 24VDC2 GND2 N C1 N C3 R1 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16 R2 R1 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16 R2 N C2 N C4 JP1 JP2 JP3...

Page 7: ...indicator guide Relay type color 1 1 Using jumper bar The right figure example is for 4 ABL L01 units with jumper bar For power common insert a jumper bar to top For load common insert it to bottom A...

Page 8: ...cutting V groove Jumper bar Jumper socket part Installation 1 Mounting and removal at DIN rail Mounting 1 Pull the rail lock towards direction 2 Attach the DIN rail connection part onto the DIN rail 3...

Page 9: ...voltage current or Class 2 SELV power supply device 5 Wire as short as possible and keep away from high voltage lines or power lines to prevent surge and inductive noise Do not use near the equipment...

Page 10: ...Series ASL Series Power Relay SSR I O Terminal Blocks Interface Terminal Blocks Common Terminal Blocks Sensor Connector Terminal Blocks Relay Terminal Blocks I O Cables Connector Type Cables Open Typ...

Reviews: