BIS-411-LED

Bistable relay

F&F Filipowski sp. j.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: [email protected]

Do not dispose of this device in the trash along with other waste! 

According to the Law on Waste, electro coming from households free of charge and can 

give any amount to up to that end point of collec� on, as well as to store the occasion of 

the purchase of new equipment (in accordance with the principle of old-for-new, regard-

less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Electronic bistable pulse relay BIS-411-LED allows switching on 

or off the lighting or other device from several different points 

by parallel connected, momentary (bell) control switches.

The receiver is switched on after a current pulse caused by pres-

sing any momentary (bell) button connected to the relay. After 

the next pulse, the receiver will be switched off.

The relay does not have a „memory” of the contact position, 

which means in the event of a power failure and its  subsequ-

ent return, the relay contact will be set to „off”. This prevents 

the controlled receivers from being switched on automatically 

without supervision after a prolonged power failure.

Purpose

Functioning

Summary of Contents for BIS-411-LED

Page 1: ...bandoned in nature pose a threat to the environmentandhumanhealth Electronic bistable pulse relay BIS 411 LED allows switching on or off the lighting or other device from several different points by parallel connected momentary bell control switches The receiver is switched on after a current pulse caused by pres sing any momentary bell button connected to the relay After the next pulse the receiv...

Page 2: ...ix the relay on a rail in the control box 3 Connect the power wires to terminals 1 3 according to the se lected relay control option control pulse L or N 4 Momentary switches connected in parallel connect to terminal 6 and the wire to which terminal 3 is connected 5 Powered receiver connect in series to terminals 11 12 The maximum total backlight current of all connected buttons must not exceed 5 ...

Page 3: ... 3 1 3 relay power supply 165 265 V AC 6 control input 11 12 NO contact active Wiring diagram ...

Page 4: ... 4 1 3 relay power supply 165 265 V AC 6 control input 11 12 NO contact active ...

Page 5: ...4 Nm working temperature 25 50 C dimensions 1 module 18 mm mounting on TH 35 rail ingress protection IP20 tungsten halogen fluorescent energy saving LED 2000W 1250W 1000W 500W 250W The above data are indicative and will heavily depend on the design of a specific receiver that is especially important for LED bulbs energy saving lamps electronic transformers and pulse power supply units switching fr...

Page 6: ... j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the references to the standards in relation to which conformity is declared can be found at www fif com pl on the product page Warranty CE declaration E200409 ...