manualshive.com logo in svg
background image

TI062

      400-062-000-B                    2008-07-04                    1/2

TI062

Installation and User Guide

Programmable Multi-purpose Timer

The TI062 timer can be used indoors and outdoors to control lighting,
motors and block heaters. The timer provides 5 modes of operation:

NOTE 1: Suitable for use with outdoor appliances. Store indoors
when not in use.

NOTE 2: To reduce the risk of electric shock, the timer has a
grounding-type plug, which has a third (grounding) pin. This plug will
fit only in a grounding-type outlet. If the plug does not fit in the outlet,
contact a qualified electrician to install the proper outlet. Do not
modify the plug in any way.

Plug the timer in an electrical outlet before setting it for the first time.
The clock flashes to indicate that it must be set*. When the timer has
been charged for at least 2 hours, it can be unplugged for several
minutes without losing the time. The other settings are saved at all
times.

The clock will still tick even if it is not set. When this happens, the

on/off times of the controlled appliance might be shifted.

You can set the timer in any of the following modes:

Manual mode

Automatic mode (default mode)

Automatic mode with temperature threshold

Automatic mode with darkness threshold

Sunset/sunrise mode

To switch mode, use the programming menu. For example, to switch
from Automatic mode to Manual mode:

n

Hold the 

On/Off

 button for 3 seconds to 

enter the menu. The 

Mode

 menu will 

flash.

o

Press the 

On/Off

 button briefly. The 

current mode will flash on the screen.

p

Press the   button repeatedly until the 
desired mode flashes on the screen.

q

Hold the 

On/Off

 button for 3 seconds to 

exit the menu.

NOTE: The timer automatically returns to its
normal display if you do not press any button
for 60 seconds.

4.1

Manual mode 

The timer operates like a regular switch. It
applies or cut power to the appliance when
you press the 

On/Off

 button.

4.2

Automatic mode 

The timer applies and cuts power to the
appliance at the desired times by means of a
program. Power is applied at the start  of the
program and is cut at the end of the program.
By default, the program starts at 6:00 pm and
ends at 11:00 pm. see section 6 on how to set
the start program time and end program time.

4.3

Automatic mode with temperature threshold 

When the timer is plugged to an outdoor outlet,
this mode is used to activate an appliance
such as an engine block heater or gutter
heating cables when the temperature drops.
Heating starts when both following conditions
are met:

The program has started.

The temperature threshold is reached (see the different
temperature threshold options in the following table). The   icon
flashes when the threshold is not reached.

See section 6 for program setting and temperature threshold
selection.

Heating will stop at the end of the program or when the temperature
rises above the threshold by a few degrees. However, heating will
resume if the temperature drops again before the end of the program.

CAUTION: Do not use the timer for temperature control applications.

4.4

Automatic mode with darkness threshold 

When the timer is plugged to an outlet
exposed to daylight, this mode is used to turn
lights on at sunset and turn them off at a set
time. The lights turn on when both following
conditions are met:

The program has started (see section 6).

The darkness threshold is reached. The   icon flashes when the
darkness threshold is not reached.

The lights will turn off at the end of the program.

NOTE: Ensure that the timer is positioned such that the light sensor is
pointing to an area that is undisturbed by car lights, outdoor lights, etc.

n

Applications

1.

Mode

Ideal for

Automatic mode

• indoor and outdoor lights (at set times)
• swimming pool pumps

Automatic mode with 
temperature threshold

• engine block heaters
• gutter heating cables

Automatic mode with 
darkness threshold

• outdoor lighting during the evening

Sunset/sunrise mode

• outdoor lighting during the night

Manual mode

• when you do not wish the controlled 

appliance to turn on or off automatically.

o

First Use

2.

p

Description of Controls

3.

q

Setting the Mode of Operation

4.

Light sensor

The LED illuminates when power is applied 
to the controlled appliance.

Press briefly to apply or cut power to the controlled 
appliance.
Press for 3 seconds to enter or exit the setup menu.

Navigation and adjustment buttons

The timer is rainproof when held in the upright 
position using the support.

Temperature Threshold

Recommended Applications

-12 °C (10 °F) [default]

gas engine block heaters

-6 °C (21 °F)

diesel engine block heaters

3 °C (37 °F)

gutter heating cables

400-062-000-B ENG.fm  Page 1  Friday, July 4, 2008  9:37 AM

Отзывы: