TI040

                    1/2

33-00024EF-03

TI040

Installation and User Guide

Industrial Indoor / Outdoor Timer

• Line voltage selector switch (120, 208/240V)
• Can function as a regular switch or as a programmable timer
• Up to 7 programs (7 on settings / 7 off settings) per week
• A single-pole switch can be connected to the timer to control the

load similar to a 3-way installation. For example, the timer can be
installed outside whereas the switch can be located remotely (e.g.,
inside the house)

• Can be used in various applications (see table below)

1.

Cut power at the main electrical panel to avoid electric shock.

2.

Open the TI040 door and remove the plastic cover to access 

the mounting holes and wire terminals.

3.

Install the TI040 to a vertical surface such as a wall by means 

of three screws (not supplied).

WARNING: To prevent rain infiltration or any other liquid from the 

top, the TI040 must be installed in the upright position as shown 

above.

4.

Remove the necessary knockouts at the bottom of the housing.

5.

Install strain-relief bushings over the knockouts, pass the wires 

through the bushings and secure them in place.

6.

Perform the connections as shown on the wiring diagram.

NOTE:

For a 3-way installation only, connect a regular single-pole 

switch to the 3-way terminals of the timer as shown on the 

wiring diagram.

7.

Select the proper input voltage by means of the voltage selec-

tor switch. (WARNING: Failure to do so can damage the prod-

uct.)

8.

Reinstall the plastic cover and apply power at the main electri-

cal panel.

At power-on, 0:00 should flash. Otherwise, press 

reset

 using a paper

clip. If the display is blank, verify the power supply.

NOTE

: The switch displays the time in 24-hour format by default or

following a reset. 

1.

To change to 12-hour format (or vice versa), proceed as fol-

lows:

a) Press the 

MODE

 button to ensure the 

MAN

 or 

AUTO

 indica-

tor is displayed.

b) Press the 

MIN

 and 

HOUR

 buttons simultaneously and briefly 

(

0:00

 display = 24-hour, 

12:00

 display = 12-hour).

2.

Set the time using the HOUR and MIN buttons. If you have 

selected the 12-hour format, ensure that PM appears on the 

screen when an afternoon time is displayed.

3.

Set the day by using the DAY button.

4.

Press the MODE button to return to normal operation.

About your new timer

1.

Load type Maximum load

Examples

Resistive
load

30 A

incandescent lights

halogen lights

block heater

Inductive
load

10 A

fluorescent lights

compact fluorescent lights (CFL)

sodium lamps

electronic ballasts

LED

Motor

1.5 hp @ 120 VAC
2.0 hp @ 240 VAC

pool filter pumps

fans

Installation

2.

Knock-out

Power-up

3.

Setting the clock

4.

Power supply 

(120/208/
240 VAC)

Single-pole switch 

(for 3-way installation)

Line voltage 

selector 

switch

Motor

Lighting

 

• Briefly press the button to 

turn the load On or Off.

• Press the button for 3 

seconds to switch 
between Automatic mode 
and Manual mode.

Mode display

On/Off display

Program number

Insert a paperclip 
to reset the timer.

Содержание TI040

Страница 1: ... of the voltage selec tor switch WARNING Failure to do so can damage the prod uct 8 Reinstall the plastic cover and apply power at the main electri cal panel At power on 0 00 should flash Otherwise press reset using a paper clip If the display is blank verify the power supply NOTE The switch displays the time in 24 hour format by default or following a reset 1 To change to 12 hour format or vice v...

Страница 2: ...n only Requires a dry contact Battery backup During a power outage the screen is blank but the programs are preserved using an internal rechargeable battery Operating temperature range 40 C to 50 C 40 F to 122 F Enclosure type 3R Certifications CSA UL Resideo warrants this product excluding battery to be free from defects in workmanship or materials under normal use and service for a period of thr...

Страница 3: ...stré sur le schéma de câblage 7 Sélectionner la tension secteur AVERTISSEMENT A défaut de le faire vous risqueriez d endommager le produit 8 Remettre le couvercle de plastique et remettre le circuit sous tension à partir du panneau électrique principal Lors de la mise sous tension 0 00 clignotera Dans le cas contraire appuyer sur reset à l aide d un trombone Si rien n apparaît à l écran vérifier l...

Страница 4: ...ntation 120 208 240 Vca 50 60 Hz Charge maximale Voir la section 1 Sortie bipolaire unidirectionnel DPST Entrée pour une installation à 3 voies Nécessite un contact sec Autonomie Lors d une panne de courant l écran est éteint mais les programmes sont conservés au moyen d une pile rechargeable intégrée Température de fonctionnement 40 C à 50 C 40 F à 122 F Type de boîtier 3R Certifications CSA UL R...

Отзывы: