SPECIFICATIONS

 

DESCRIPTION

 

3

WARNING

Easily switch between 

Automatic Timer 

and 

Manual Control 

by pressing the 

M

ODE 

button.

Anytime in Automatic or Manual mode, the load can be switched ON/OFF manually by 

pressing the 

MAN

 button or front cover plate when it is closed.

The large and easy-to-read LCD screen displays the current day of week, time, Auto/Manual 

mode, whether the Load is ON or OFF, and in programming, the program settings.

The Timer can be programmed up to 18 ON and 18 OFF settings.

1.

Connect 

the 

BLACK wire 

from

 switch 

to the HOT 

wire

.

2.

Connect 

the 

WHITE wire 

from

 switch 

t

o the NEUTRAL 

wire.

3.

Connect the R

ED

 wire 

from

 switch to the LOAD wire.

a.

If using 3-way

 on the HET01-3

C

Connect 

each RED

 

wire 

to 

each 

TRAVELER

 

wire

.

4.

Connect 

t

he GREEN wire 

from

 switch 

to the GROUND 

wire or 

the 

green GROUND 

screw

on 

the 

box. 

HET01-C/ HET01-3C

7-day Digital In-Wall Timer

The 7-day digital timer is your solution to automated indoor and outdoor lighting. The Timer is 

easy to program and is customizable for each day of the week. The HET01-C can replace a 

standard single pole wall switch and the HET01-3C can replace a 3-way switch. Th

e HET01

 

Timer can control incandescent lights, fluorescent lights, flood lights, stereos, or 

heavy-duty 

load.

FEATURES

HET01-

C

MIN

MAN

HOUR

PROG

MAN

MAN

OFF

ON

INDOOR

MO

OFF

AUTO

P

R

DAY

USE ONLY

HET01-3

C

MIN

MAN

RCL

HOUR

PROG

MAN

MAN

OFF

ON

INDOOR

MO

OFF

AUTO

P

R

DAY

USE ONLY

MODE

MODE

Motor…….....…..…….................…….....................

….................

........................................1/2HP  

Voltage ……………………………………...........…

….................

….................….. 120VAC, 60Hz   

Resistive………..........…...…….…………...........

….................

.............................15Amp, 1800W

Tungsten..........................................................

….................

.............................................1200W

Ballast......................................................

….................

....................................................1200VA

INSTALLATION INSTRUCTIONS

Turn the POWER OFF at the circuit breaker before 

installing the 

Timer

Read and understand these instructions before installing. It is recommended that a qualified 

electrician performs this installation.  Make sure to turn off the circuit breaker or fuse(s) and 

make sure power is off before wiring the device. This product is Listed to applicable UL 

Standards and requirements by UL. This device is intended for installation in accordance with 

the National Electric Code and local regulations. 

Use copper wires ONLY.