background image

- INSTRUCTIONS -

The RY-1824L door release relay module is an interface between the door release contact on the Aiphone master station 
or CEU and the actual release mechanism. The contact closure directly from the master station or CEU has limited voltage 
and current capacity. Use the RY-1824L to ensure that the contact rating will be sufficient for the electric strike or magnetic 
lock used. The relay’s contact rating supports a majority of door release hardware available. This relay is recommended 
for all AX, KB, JF, JO, and JP Series systems when using door release and will protect the built-in contact from possible 
surge damage. 

(Note: Use the RY-3DL when releasing more than two doors in a JP Series, or more than one door in a JF or KB Series).

RY-1824L

Form C Door Release Relay for AX, KB, JF, JO, and JP Series

WIRING DIAGRAMS:

Page 1

INSTALLATION:

1. Install near the power source for the door release mechanism, or behind the master station or CEU.
2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
3. Trim the wires to the desired length. 
4. Trim the unused contact wire so the bare strands are not exposed. 

RED:  (+) Pos.
BLK:   (-) Neg.
BRN:   Common
ORG:  N/O
YEL:   N/C

RY-1824L COLOR CODE:
Input of Relay:

Red:

(+) Positive

Black:

(-) Negative

Output of Relay:

Brown:

Common

Orange:

N/O contact

Yellow:

N/C contact

(See contact rating specs on page 4)

1A1

1A2

M(Out)

2A1

2A2

PS-2420UL

+

-

Door #1

JP-DV

A1

A2

3A1

3A2

4A1

4A2

DOOR 1

DOOR 2

DOOR 3

DOOR 4

Blk

Brn

Org

Yel

RY-1824L

Red

LOCK 

POWER

Door  

Release

#1

Brn

Org

Yel

RY-1824L

Door 

Release

#2

Blk

Red

MAGNETIC LOCK 

WIRING METHOD:

(Normally Closed contact)

+

-

LOCK 

POWER

ELECTRIC STRIKE 

WIRING METHOD:

(Normally Open contact)

Door #2

JP-DV

A1

A2

COM
N/O
N/C

NOTE: The door release contacts on the station are rated at 24V AC/DC, 500mA. The RY-1824L should be used in any 
application where the strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the 
master station could occur.

JP Series Wiring

19310      0519

L1
L1

L2
L2

JP-4MED

RY-1824L