background image

Before using the product, please read this manual carefully and keep it for later.

Image drawings and notations in this document may slightly differ from the actual product.

The contents of this document are subject to change without notice.

English

User’s Manual

Smart Pass

(AIoT Face Recognition & Temperature Measurement for Access Control System )

Copyright ©2020 AHA INC CO.,LTD. All Rights Reserved

www.ahatouch.com

Model : 

Stand Assembly Manual

Rev.2.1

FPS-1000R

Desk stand

Floor stand

Wall bracket

Summary of Contents for Smart Pass FPS-1000R

Page 1: ...er from the actual product The contents of this document are subject to change without notice English User s Manual Smart Pass AIoT Face Recognition Temperature Measurement for Access Control System Copyright 2020 AHA INC CO LTD All Rights Reserved www ahatouch com Model Stand Assembly Manual Rev 2 1 FPS 1000R Desk stand Floor stand Wall bracket ...

Page 2: ...Main menu 3 3 Setting 3 4 Registration of access information 3 5 Device information 3 6 Access record 3 7 List of registrants 4 Countermeasure 5 Product specification 6 Product diagram 7 Product description display 8 Product description 9 Product port description 10 Maintenance 11 Installation Manual Main unit Stand 3 3 3 3 4 5 5 5 7 18 19 20 21 22 24 25 26 27 28 29 30 2 Contents ...

Page 3: ...glasses and a mask at the same time with advanced deep learning technology 2 How to use Smart Pass 2 1 How to run Smart Pass 1 When the power is connected the device turns on The app is installed on the device so there is no need for a separate installation process 2 Turn on your device and wait for a while to launch the app and it takes about 30 seconds to use it 3 In order to use a stable device...

Page 4: ... is measured and displayed on the screen If your body temperature is normal you will be informed by voice If the body temperature is high a warning tone is displayed and the entry is prohibited The mask detection function allows you to display the access only when you are wearing a mask If you are not wearing a mask you will be asked to wear a mask and a warning sign will be displayed 4 ...

Page 5: ...al phrases or body temperature measurement results are displayed Depending on the setting information such as IP company name and version may be displayed at the bottom of the screen 3 2 Main menu When the mouse is connected and the wheel button is pressed the password input window appears and when the correct password is entered the main menu is displayed on the screen The initial password is 123...

Page 6: ...tly supported 3 Application settings Open the Smart Pass detailed settings menu 4 Face registration Capture a person s face and register it in the database 5 Application information Check various information of the device 6 Pass record Displays a list of people who have measured the temperature 7 Face database Shows a list of people registered in the database 1 2 3 6 4 5 6 7 ...

Page 7: ...3 3 Setting This is a detailed menu for setting up a Smart Pass 1 Name setting Set the device name and company name 7 ...

Page 8: ...reshold If the measured body temperature is higher than the entered value an alarm message is displayed When the body temperature alarm is on a beep sounds 5 Body temperature alarm Enable or disable the Alarm 6 Temperature display Change the temperature display format to Celsius or Fahrenheit 7 Fan It set the operation of the fan for heat dissipation 8 Mask detection Measure your body temperature ...

Page 9: ... the database The lower the number the more precise the comparison Input value is 10 20 2 Comparison count Compare and check the number of times entered The bigger the number of comparisons the more accurately a person can be judged Up to 0 99 can be entered 3 Facial Liveness Detection Face Biometric Authentication This is to detect if a person in front of camera is a real person or manipulated im...

Page 10: ... Description 1 Auto start Set whether the app turns on automatically when the device is turned on 2 Application daemon When the setting is on the app will automatically appear on the screen after 30 seconds even if the app is not on the screen 3 Application thread daemon If the setting is on the camera function will restart if an error occurs while the camera is on 1 2 3 10 ...

Page 11: ... 6 Application information settings Set whether to display information such as MAC address IP and company name on the initial screen Hide Show app info setting 11 ...

Page 12: ... picture of the person is displayed or the name of the person is displayed 2 Recognition failure Choose whether to turn the light to red when the person not registered in the database is recognized or the mask is not worn If the dimmer setting is a single light this setting is not visible 3 Photo flood lamp Set whether to use all colors such as white red green lights or only white light 12 ...

Page 13: ... setting This menu is for changing the password The default password value is 123456 9 Camera resolution setting Change the camera captured screen resolution There are 640 480 resolution and 1280 720 resolution 13 ...

Page 14: ...screen is switched to the screen protection state because no person is detected for a certain period of time 11 Restart time setting Enter the hour in the upper column and the minute in the lower column on a 24 hour basis Reboot or shut down the device at the specified time 14 ...

Page 15: ... current and voltage 2A 30VDC 0 28A 220VAC Excessive use of the maximum drive current and voltage may cause product defects No Mode Description 1 Mode 0 Disable relay 2 Mode 1 When the relay is open it is closed for the set delay time and then opened again 3 Mode 2 The relay is closed and opened for the set delay time and then closed again 4 Delay time Set the operation time of the relay The initi...

Page 16: ... containing the firmware upgrade file The file name should be updateTemp bin and it should be at the top of the USB path 2 Callback setting If you select On a field for entering content appears Enter if callback setting is required 3 Communication address setting If you select On a field for entering content appears Enter the IP and port number of the server to communicate with The format is IP PO...

Page 17: ... the button is pressed the above warning appears and when the OK button is pressed various settings are initialized and all information and records registered in the database are lost Once the program initialization function is activated it cannot be reversed Back up data before initialization 17 ...

Page 18: ...ion to take a person and register it in the face database Press the Gather button at the top to take a picture The picture which was taken is scaled to fit the person s face Enter ID and name select gender and click Save to save it to the Face database 18 ...

Page 19: ...3 5 Device information Displays information about apps and devices Information such as firmware version memory brightness and volume is displayed 19 ...

Page 20: ... and photo at the time of measurement If the detected person is not in the face database it is displayed as Stranger Enter the time zone you want to see and press the query button to retrieve only the records for that time If you connect a USB storage device and press the Export button you can save the records currently in the list separately 20 ...

Page 21: ...Click the Delete button on the right to delete the person s information from the database 21 If the storage capacity of the device is full use Settings Program Reset to delete the old records At the time of initialization the record of the registrant list is also erased and the settings are initialized so please back up and record the contents If the storage capacity is full due to the access reco...

Page 22: ...e right side of the bottom menu and select Restart to reboot 2 If you want to change the language Left click and drag up from the bottom of the screen with the mouse to bring up the bottom menu Tap the circled button in the middle to go to the Android home screen and open Settings In the settings window go to the language and input settings menu as shown in the following figure 4 Countermeasure 22...

Page 23: ...u When changing the system language it is recommended to reboot the device for better usage Drag the icon on the right in Language preferences to change the order to change the device s system language Changing the system language also changes the language of the Smart Pass 23 ...

Page 24: ...tion Face Detection Support Face library Up to 30 000 1 1 face comparison Support Stranger detection Support Identify distance configuration Support Interface Interfaces include device management personnel photo management record query etc Deployment method Privatized deployment LAN use stand alone use Infrared thermal imaging module Temperature detection Support Temperature detection distance 1 m...

Page 25: ...25 6 Product diagram ...

Page 26: ...26 7 Product description display ...

Page 27: ...27 8 Product description ...

Page 28: ...WG IN Wiegand input WG OUT Wiegand output For installation experts and administrators RJ 45 RS232 For installation experts and administrators 28 9 Product port description ...

Page 29: ...10 Maintenance Precautions 29 ...

Page 30: ... unit and floor stand Put the stand upright and remove the fixed screws 6ea to disassemble the cover of the top of the stand 1 Disassemble the table cover 2 The main unit and stand assembly Put the cables in the hole of the stand and insert the main unit into the stand and Connect USB x2 and LAN DC cables of the main unit to the each cables of the stand and put the connected cables in the stand bo...

Page 31: ...31 USBx2 DC JACK LAN Enables USB X2 and LAN DC Jack to be connected to the body and the support 4 assembly of stand body and pedestal ...

Page 32: ...e the cover and table stand 2 Disassemble the table stand Put the cables in the hole of the stand and insert the main unit into the hold of the stand and fix the 3 The main unit and stand assembly FH M3 6 SCREW x3 STAND FOOT x 3 Connect the LAN and DC Jack of the stand to the main unit and close the stand cover and fix the cover with the screws and the stand foots Pull USB and other terminals out ...

Page 33: ...stallation 벽면에 설치 Wall Installation Product weight size 重量 kg サイズ mm FPS 1000R 1 4 132 9 W x 296 2 H x 25 D Desk stand 3 5 321 4 W x 413 5 H x 288 6 D Floor stand 8 321 4 W x 1532 6 H x 288 6 D Wall bracket 1 4 132 9 W x 296 2 H x 25 D ...

Page 34: ...34 Model FPS 1000R Desk stand Floor stand Wall bracket ...

Page 35: ...Memo ...

Page 36: ...Tel 82 31 997 0909 e mail sales ahatouch com www ahatouch com All specifications are subject to change without prior notice to improve the product ...

Reviews: