108 Diagnostics & Troubleshooting
DSP code checksum, DSP RAM memory, EEPROM, digital
circuits, and the analog circuit calibrations.
Results of the power-on self-test displayed on your terminal:
0 SYSTEM TESTING
....
Self-test indicator. If no error occurs,
this message will last until the end of
the test.
1 ROM TEST FIAL....
ROM code checksum error.
2 RAM TEST FAIL....
System RAM fails.
3 LOADING
DEFAULTS.
EEPROM checksum error. The
factory default settings will be
downloaded to the EEPROM and the
self-test will be re-initiated. This is
not a real error.
4 DSP RAM FIAL...
The testing of DSP RAM fails,
condition A.
5 DSP RAM FIAL...
The testing of DSP RAM fails,
condition A.
6 VO CALIBRATION
FAIL...
Analog circuit calibration error.
7 VR CALIBRATION
FAIL...
Analog circuit calibration error.
8 FR CALIBRATION
FAIL....
Analog circuit calibration error.
Resetting The Modem
A reset command from the panel will restart the power-on self-test.
If an error message is displayed on the screen, turn off the modem,
wait for at least 10 seconds, and then turn the power on again. If
the error condition persists, call the ZyXEL Service Center for
assistance, or follow the return procedure to return the modem to
ZyXEL. If the normal IDLE SCREEN shows up, the original
failure was due to a temporary power-on reset problem and will not
affect modem operation.
Summary of Contents for U-336E
Page 1: ...U 336E User s Manual Version 1 0 Mar 1997 ZyXEL ACCESSING INTERNET INTRANET ...
Page 12: ...xii 12 Index 124 ...
Page 18: ...6 Introduction ...
Page 24: ...12 Installation ...
Page 42: ...30 Leased Line Operation ...
Page 56: ...44 Special Functions ...
Page 118: ...106 Status Registers Result Codes ...
Page 135: ...Connector Pinouts 123 ...