Chapter 2 The RESET/ENCRYPT Button
PLA5236 User’s Guide
14
Fig ure 4
Adding More Powerline Adapters to Your Network
This sets up your powerline network between your powerline devices.
2.3 Re m o ving a De vic e fro m a Po we rline Ne two rk
Suppose you want to remove PLAs (
C
) and (
D
) from the following powerline network.
Fig ure 5
Removing Devices From an Existing Powerline Network
1
Press the
RESET/ ENC RYPT
button on powerline device
C
for 5 to 8 seconds and then release it. This
disconnects
C
from the current network.
2
Press the
RESET/ ENC RYPT
button on powerline device
D
for 5 to 8 seconds and then release it. This
disconnects
D
from the current network.
A
B
C
A OR B
D
A OR B OR C
A
C
B
D