4/4
Pole Mounting (Optional)
M6 Spring Washers
U-Type Screws
x2
x4
M6 Washers
x4
M6 Hex Nuts
x4
Place the U-bolt around a pole. Insert the U-bolt into the holes on the main frame. Use a wrench
to secure the main frame to the pole with the washers, spring washers, and nuts.
1
Step 6
Pole / Wall Mounting Angle Adjustment
-40°
horizontal
+40°
+0°
horizontal
45°
vertical
-48°
vertical
Connect the PoE injector to a power outlet. Use the LTE Ally app to find the optimal LTE signal strength and manage your LTE7485-S905.
Note: After configuring the LTE7485-S905, turn WiFi off.
Safety Warnings
Humid
、
dusty and extreme environment in which place the product and obstructing the device ventilation
slots are prohibited, any kind of conditions above may harm your device.
There is a remote risk of electric shock from lightning.
do not install, use, or service this device during a thunderstorm.
Connect only suitable accessories to the device; make sure to connect the cables to the correct ports.
Do not open the device, opening or removing covers can expose you to dangerous high voltage points or
other risks. Please contact your vendor for further information.
Place connecting cables carefully so that no one will step on them or stumble over them and disconnect all
cables from this device before servicing or disassembling.
Please use the provided or designated connection cables/power cables/ adaptors. connect it to the right
supply voltage (for example, 110V AC in North America or 230V AC in Europe), If the power adaptor or cord
is damaged, it might cause electrocution. remove it from the device and the power source , repairing the
power adapter or cord is prohibited , Contact your local vendor to order a new one.
Risk of explosion if battery is replaced by an incorrect type, dispose of used batteries according to the
instruction.
Please refer to the device back label, datasheet or box specifications catalog information for rated power
of device and operating temperature.
The socket-outlet shall be installed near the device, and shall be easily accessible because it serves as the
main disconnecting device.
Disposal and Recycling Information
The symbol below means that according to local regulations your product and/or its battery
shall be disposed of separately from domestic waste. If this product is end of life, take it to a
recycling station designated by local authorities. At the time of disposal, the separate collection of
your product and/or its battery will help save natural resources and ensure that the environment
is sustainable development.
Secure a green/yellow ground cable (18 AWG or smaller) to the LTE7485-S905’s rear panel using the M4 ground screw. Attach the
other end of the cable to the ground, either to the same ground electrode as the pole you installed the device on or to the main
grounding electrode of the building. Follow your country’s regulations and safety instructions to electrically ground the device
properly. Qualified service personnel must confirm that the building’s protective earthing terminal is valid.
Step 7
Grounding