(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, www.zwaveeurope.com
pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive a
common wireless command.
Association Groups:
1
Battery Status and Sensor Report (max. nodes in group: 1)
2
Sensor Triggered (max. nodes in group: 3)
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better
to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: to set a parameter to 200 it may be needed to set a value of
200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given
as negative values too.
Basic Level Set (Parameter Number 1, Parameter Size 1)
Set basic set value to be on or off
Value
Description
0
Disable
1 — 99
Use value (Default 99)
Temperature Trigger ON value (Parameter Number 2, Parameter Size 1)
Temperature level when a ON
command is sent out
Value
Description
236 — 255
Trigger On on
0 — 50
Trigger On on
99
Disable (Default)
Temperature Trigger OFF value (Parameter Number 3, Parameter Size 1)
Trigger Temperature level when a
OFF command is sent out
Value
Description
236 — 255
Trigger Off on
0 — 50
Trigger Off on
99
Disable (Default)
Humidity Trigger ON value (Parameter Number 4, Parameter Size 1)
Humidity level when a ON command is
sent out
Value
Description
20 — 90
Trigger On on