Press Select Mode button and select MODE 3 to enter setting of temperature trigger-ON. Icon flashes and the screen shows the
recorded trigger-ON temperature. If no value is preset, the screen will display " - - -°C ".
To adjust trigger-ON value, press and hold Select Mode button for 5 seconds until a long beep is sounded. The "- - -" starts flashing.
Use Min. and Max. button to adjust the degree of temperature, and hold Min. or Max. button to scan through the temperature
reading from -20°C to 50°C. Once the value is selected, press Select Mode button to confirm setting or press Linking button to
cancel.
To clear the trigger-ON record, press both Min. and Max. button at the same time. The record is cleared after a long beep is
sounded.
If the temperature reaches the preset trigger-ON value, Temp./Humid. Detector will send a Z-Wave signal. The screen of detector
returns to MODE 1 and the icon "ON" is flashing with backlight illuminate and siganl tone sounds for 1 second. Press any key to
stop the signal tone.
1.3 Temperature Trigger-OFF
Press Select Mode button and select MODE 4 to enter setting of temperature trigger-OFF. The "OFF" icon flashes and the screen
shows the recorded trigger-OFF temperature. If no value is preset, the screen will display "- - -°C".
To adjust trigger-OFF value, press and hold Select Mode button for 5 seconds until a long beep is sounded. The "- - -" starts
flashing. Use Min. and Max. button to adjust the degree of temperature, and hold Min. or Max. button to scan through the
temperature reading from -20°C to 50°C. Once the value is selected, press Select Mode button to confirm setting or press Linking
button to cancel.
To clear the trigger-OFF record, press both Min. and Max. button at the same time. The record is cleared after a long beep is
sounded.
If the temperature reaches the preset trigger-OFF value, Temp./Humid. Detector will send a Z-Wave signal. The screen of detector
returns to MODE 1 and the icon is flashing with backlight illumination and siganl tone sounds for 1 second. Press any key to stop
the siganl tone.
Note:
The temperature trigger-ON and trigger-OFF cannot be set equal; there MUST be at least 2°C difference in between. For example,
if now the trigger-OFF temperature is already set to be 20°C, so trigger-ON temperature can only be lower 18°C or higher 22°C
(values between 18°C and 22°C cannot be set).
Once the detector has been triggered, the temperature must increase or cool down at least 2°C from the preset value before it can
be triggered again. For example, if the detector is triggered on at 20°C, then the temperature must be higher 22°C or lower 18°C
before it can be re-triggered.
2. Humidity
2.1 Display of Current Humidity
Press Select Mode button and select MODE 2 to display current humidity.
The humidity ranges from 20% RH to 90% RH. To show the last record of max/min humidity, press Min. or Max. button. To clear the
record, press both Min. and Max. button at the same time.
Threshold Limit Warning:
If the humidity is reaching the limit, the icon of MAX or MIN will be displayed on the screen.
2.2 Humidity Trigger-ON
Press Select Mode button and select MODE 5 to enter setting of humidity trigger-ON. The "ON" icon flashes and the screen shows
the recorded trigger-ON humidity. If no value is preset, the screen will display "- - -%".
To adjust trigger-ON value, press Select Mode button and hold for 5 seconds until a long beep is sounded. The "- - -" starts flashing.
Use Min. and Max. button to adjust the percentage of humidity, and hold Min. or Max. button to scan through the humidity reading