9
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, www.zwaveeurope.com
99
Disable (Default)
Humidity Trigger OFF value (Parameter Number 5, Parameter Size 1)
Humidity level when a OFF command is
sent out
Value
Description
20 — 90
Tigger Off on
99
Disable (Default)
Auto Report Time (Parameter Number 6, Parameter Size 2)
Sets the time interval when a sensor report is sent
Value
Description
0
Disable (Default)
1 — 1439
Auto report periodically
Auto Report Temperature (Parameter Number 7, Parameter Size 1)
Sets the temperature change causing a
sensor report
Value
Description
0
Disabled (Default)
1 — 70
Auto report on temp. change
Auto Report Humidity (Parameter Number 8, Parameter Size 1)
Sets the humidity change causing a sensor
report
Value
Description
0
Disable (Default)
5 — 70
Auto report on humidity change
Command Classes
Supported Command Classes
Basic (version 1)
●
Multi Channel (version 2)
●
Wake Up (version 2)
●
Association (version 2)
●
Version (version 1)
●
Battery (version 1)
●
Configuration (version 1)
●
Multilevel Sensor (version 2)
●
Manufacturer Specific (version 1)
●
Technical Data