Seite 8
ZUWA-Zumpe GmbH • Franz-Fuchs-Str. 13-17 • 83410 Laufen • Tel.: +49 (0) 8682 – 89340 • E-Mail: [email protected]
DESCAL
8
6. Mounting and commissioning
Warnung
Danger of chemical burn after contact with descaling agent
> Wear acid proof gloves when working with descaling agents
.
Caution
Material damage due to overheating of the pump
> Never allow the pump to run dry for more than 1 minute.
1. Place the device on a flat spot to avoid the
device from tilting over.
2. Connect filling hose to pump outlet.
3. Connect return hose to tank.
4. Fill tank.
Caution: danger of chemical burn from
leaking liquid
> Do not fill the tank with more than
50% with descaling agent. The
chemical reaction between agent and
scale cause heavy foaming.
5. Open tank lid to ensure the circulation of
the air.
When working with heavily stained liquid it is recommended to hinge
additional fleece flters into the tank to protect the fine filter.
Article code fleece filter set: 132003