1. Cut pipe so that the height of the finished drain is at or just
below the height of the finished floor. (See Zurn Engineering
Handbook or EZ1
TM
Submittal for dimensional heights). Ensure
pipe is cut square and free of burrs or debris. See Fig. 1
2. Install drain body on pipe and pressure test connection per local
code requirements. See Fig. 2 (Neo-loc body shown for
reference)
Note: All plastic bodies to be solvent welded to pipe
3. Pour the rough floor slab flush with the top of the drain body.
See Fig. 3
Fig. 2
Fig. 3
Warning: Flying material can cause eye injury or blindness and sharp edges could cause cuts or
lacerations. Wear safety glasses and gloves when installing or working on drain.