Messages
12
5 Messages
5.1
Error Messages
5.2
General messages
Pos.
Error
Text
Description
1
730
Wrong setting
<ENT> for Abort
The automatic knife initialisation was released with a wrong tool
(Punch, Pen, Passepartout).
2
731-1/2
HW fault
<ENT> for Abort
An error has occurred during the light barrier test. Check the
plug connection; check the light barrier for contaminations.
3
732
No knife initialisation
<ENT> for Abort
During the automatic initialisation knife or cutter is not detected;
The initialisation process was aborted by user.
4
734
Error KnifeSetting.
Switching off plotter
If a fault outside of this process occurs during the automatic
knife initialisation (safety light barrier ...), it is aborted and the
plotter must be switched off and then restarted.
5
735
Tool correction
value is too high for AKI
Error message appears, if the value
ADJUST XY (
241
) > 0.5 mm. abort with ESC. Correct the value
or deactivate the value ADJUST XY with ENABLE (
244
).
6
733
Pen down too deep
Pos down set on zero
After the automatic knife initialisation the setting POS DOWN
(
1182
) and Z-OFFSET (
1183
) were entered. If the resultant
PEN DOWN Position is below the maximum possible, lower
position, this message appears. (See Fig. 2, Pos. A)
The values DOWN POS and Z-OFFSET are set on zero.
Text
Description
XY-Init. blocked
Re-place AKI
Continue with ENT
Message before the initialisation of X and Y axes after Power on
Online blocked
Re-place AKI
CE/ESC for aborting
Continue with ENT
Message while switching to Online operation, if the AKI2 is not in
the park station.
Function blocked
Re-place AKI
CE/ESC for Aborting
Continue with ENT
Message while calling (Start) a function in the Offline Mode, which
executes a movement.
manual Tz-Init
You are sure
CE/ESC for Aborting/
cancelling
Continue with ENT
Enquiry while changing from the automatic to the manual Tz
initialisation. At a confirmation with ENT the manual initialisation is
performed. The function AKI is switched to OFF for the current tool
(
11853
-
11856
). It is cancelled with ESC/CE.
Summary of Contents for AKI 2