background image

Instruction Manual

Messages

12

AKI 2

6. July 2006, muj, _1

5 Messages

5.1

Error Messages

5.2

General messages

Pos.

Error

Text

Description

1

730

Wrong setting
<ENT> for Abort

The automatic knife initialisation was released with a wrong tool 
(Punch, Pen, Passepartout).

2

731-1/2

HW fault
<ENT> for Abort

An error has occurred during the light barrier test. Check the 
plug connection; check the light barrier for contaminations.

3

732

No knife initialisation
<ENT> for Abort

During the automatic initialisation knife or cutter is not detected; 
The initialisation process was aborted by user.

4

734

Error KnifeSetting.
Switching off plotter

If a fault outside of this process occurs during the automatic 
knife initialisation (safety light barrier ...), it is aborted and the 
plotter must be switched off and then restarted.

5

735

Tool correction
value is too high for AKI

Error message appears, if the value
ADJUST XY (

241

) > 0.5 mm. abort with ESC. Correct the value 

or deactivate the value ADJUST XY with ENABLE (

244

).

6

733

Pen down too deep
Pos down set on zero

After the automatic knife initialisation the setting POS DOWN 
(

1182

) and Z-OFFSET (

1183

) were entered. If the resultant 

PEN DOWN Position is below the maximum possible, lower 
position, this message appears. (See Fig. 2, Pos. A)

The values DOWN POS and Z-OFFSET are set on zero. 

Text

Description

XY-Init. blocked
Re-place AKI
Continue with ENT 

Message before the initialisation of X and Y axes after Power on

Online blocked
Re-place AKI
CE/ESC for aborting
Continue with ENT 

Message while switching to Online operation, if the AKI2 is not in 
the park station.

Function blocked
Re-place AKI
CE/ESC for Aborting
Continue with ENT 

Message while calling (Start) a function in the Offline Mode, which 
executes a movement.

manual Tz-Init 
You are sure
CE/ESC for Aborting/
cancelling
Continue with ENT 

Enquiry while changing from the automatic to the manual Tz 
initialisation. At a confirmation with ENT the manual initialisation is 
performed. The function AKI is switched to OFF for the current tool 
(

11853

 - 

11856

). It is cancelled with ESC/CE.

Summary of Contents for AKI 2

Page 1: ...AKI 2 w00018...

Page 2: ...4 3 Safety requirements 4 3 2 Proper use 5 3 3 Examples of improper use 5 3 4 Danger due to improper use 5 4 Operation 6 4 1 General 6 4 1 Menu tree 7 4 2 Insert 8 4 3 Height adjustment 9 4 4 Automati...

Page 3: ...matic Knife Initialisation is used for automatic knife initialisation of following uses of tool Implementation case with various knives EOT 40 EOT 3 POT 40 Plus POT 40va DRT 1 KW Milling spindle 450 W...

Page 4: ...r which the tool is intended contains safety precautions and instructions that apply to this tool in particular Gives information on required protective equipment for work and maintenance Special oper...

Page 5: ...solely liable for any damages resulting from improper use Use of the tool shall be regarded as proper if all nationally imposed safety requirements are met If the safety requirements listed in this o...

Page 6: ...n operating position 5 Desktop panel 3 AKI2 A Position below limit C OFFSET T1 T4 118521 118524 Position below limit 1 2 mm This preset value sets the cutting depth of 0 3 mm in the cutting base B Dis...

Page 7: ...5 Z INIT AUTO Automatic knife initialisation 11851 START Releasing the automatic knife initialisation 11852 SETTING Input of the setting value for the OFFSET 1 118521 4 OFFSET1 T1 4 Setting of the Off...

Page 8: ...Instruction Manual Operation 8 AKI 2 6 July 2006 muj _1 4 2 Insert Fig 4 Insert AKI2 Put AKI2 in the park station Insert AKI2 The AKI2 is now ready for operation w00024...

Page 9: ...lockwise Put the AKI2 flat on the cutting base Fig 5 Pos 2 Set the set screw Fig 5 Pos 4 lower clockwise lift anticlockwise that it touches the table top Important Ensure that the set screw is set suc...

Page 10: ...ures that the AKI2 is lying flat on the table surface C After starting the initialisation 11851 the active module is positioned automatically above the initialisation groove of the AKI2 Caution Risk o...

Page 11: ...6 Park station Fig 7 AKI2 place of deposit After the automatic initialisation place the AKI2 on the park station Important The value for AKI OFFSET1 T1 T4 118521 118524 is set on 1 2 mm as standard pr...

Page 12: ...ct the value or deactivate the value ADJUST XY with ENABLE 244 6 733 Pen down too deep Pos down set on zero After the automatic knife initialisation the setting POS DOWN 1182 and Z OFFSET 1183 were en...